Experimental determination of efficiency factors for different Micro-CHP units according to the standard DIN 4709

  • Since November 2011 the standard DIN 4709 stipulates performance tests for Micro-CHP units in Germany. In contrast to steady state measurements of the CHP unit itself, the test according to DIN 4709 includes the thermal storage tank as well as the internal control unit, and it is based on a 24 h test cycle following a specified thermal load profile. Hence, heat losses from the storage tank are as well taken into account as transient losses of the CHP unit. In addition, the control strategy for loading and unloading the storage tank affects the test results. The DIN 4709 test cycle has been applied at the test stand for Micro-CHP units at Reutlingen University, and results for the Micro-CHP unit WhisperGen and the EC Power units XRGI 15® and XRGI 20® are available. During the analysis a method has been developed to evaluate the results in case the test cycle does not end in a time slot between 24 and 24.5 h after the starting as demanded by DIN 4709. Since this method has been successfully applied to the test of various CHP units of different size and technology so far, it is suggested to incorporate it to DIN 4709 during the next revision of the standard. The performance numbers obtained reveal the differences in efficiencies measured at steady-state on the one hand and following the DIN 4709 test cycle on the other hand. While the deviations in electrical efficiencies are small, thermal efficiencies according to DIN 4709 fall below steady state data by 3–6 percentage points. This is attributed to transient thermal losses and heat losses from the storage tank, which are not included in steady state and separate testing of the CHP unit, only.

Download full text files

  • 112.pdf
    eng

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author of HS ReutlingenThomas, Bernd
DOI:https://doi.org/10.1016/j.applthermaleng.2013.10.068
eISSN:1359-4311
Erschienen in:Applied thermal engineering
Publisher:Elsevier
Place of publication:Amsterdam
Document Type:Journal article
Language:English
Publication year:2014
Tag:DIN 4709; efficiency; performance test; test cycle
Volume:71
Issue:2
Page Number:8
First Page:721
Last Page:728
DDC classes:620 Ingenieurwissenschaften und Maschinenbau
Open access?:Nein
Licence (German):License Logo  In Copyright - Urheberrechtlich geschützt