Refine
Document Type
- Journal article (37)
- Book chapter (2)
Is part of the Bibliography
- yes (39)
Institute
- Life Sciences (37)
- Informatik (2)
Publisher
- De Gruyter (15)
- Macmillan Publishers Limited (3)
- ACS (2)
- CRC Press (2)
- Elsevier (2)
- MDPI (2)
- Nature Publishing Group (2)
- Royal Society of Chemistry (2)
- Wiley (2)
- de Gruyter (2)
Perivascular stromal cells, including mesenchymal stem/stromal cells (MSCs), secrete paracrine factor in response to exercise training that can facilitate improvements in muscle remodeling. This study was designed to test the capacity for muscle-resident MSCs (mMSCs) isolated from young mice to release regenerative proteins in response to mechanical strain in vitro, and subsequently determine the extent to which strain-stimulated mMSCs can enhance skeletal muscle and cognitive performance in a mouse model of uncomplicated aging. Protein arrays confirmed a robust increase in protein release at 24 h following an acute bout of mechanical strain in vitro (10%, 1 Hz, 5 h) compared to non-strain controls. Aged (24 month old), C57BL/6 mice were provided bilateral intramuscular injection of saline, non strain control mMSCs, or mMSCs subjected to a single bout of mechanical strain in vitro (4 ×104). No significant changes were observed in muscle weight, myofiber size, maximal force, or satellite cell quantity at 1 or 4 wks between groups. Peripheral perfusion was significantly increased in muscle at 4 wks post-mMSC injection (p < 0.05), yet no difference was noted between control and preconditioned mMSCs. Intramuscular injection of preconditioned mMSCs increased the number of new neurons and astrocytes in the dentate gyrus of the hippocampus compared to both control groups (p < 0.05), with a trend toward an increase in water maze performance noted (p=0.07). Results from this study demonstrate that acute injection of exogenously stimulated muscle-resident stromal cells do not robustly impact aged muscle structure and function, yet increase the survival of new neurons in the hippocampus.
A wide variety of cell types exhibit substrate topography-based behavior, also known as contact guidance. However, the precise cellular mechanisms underlying this process are still unknown. In this study, we investigated contact guidance by studying the reaction of human endothelial cells (ECs) to well-defined microgroove topographies, both during and after initial cell spreading. As the cytoskeleton plays a major role in cellular adaptation to topographical features, two methods were used to perturb cytoskeletal structures. Inhibition of actomyosin contractility with the chemical inhibitor blebbistatatin demonstrated that initial contact guidance events are independent of traction force generation. However, cell alignment to the grooved substrate was altered at later time points, suggesting an initial ‘passive’ phase of contact guidance, followed by a contractility-dependent ‘active’ phase that relies on mechanosensitive feedback. The actin cytoskeleton was also perturbed in an indirect manner by culturing cells upside down, resulting in decreased levels of contact guidance and suggesting that a possible loss of contact between the actin cytoskeleton and the substrate could lead to cytoskeleton impairment. The process of contact guidance at the microscale was found to be primarily lamellipodia driven, as no bias in filopodia extension was observed on micron-scale grooves.
A series of novel biomedical TPCUs with different percentages of hard segment and a silicone component in the soft segment were synthesized in a multi stage one-pot method. The kinetic profiles of the urethane formation in TPCU-based copolymer systems were monitored by rheological, in line FTIR spectroscopic (React IR) and real-time calorimetric (RC1) methods. This process-analytically monitored multi step synthesis was successfully used to optimize the production of medical-grade TPCU elastomers on preparative scale (in lots of several kg) with controlled molecular structure and mechanical properties. Various surface and bulk analytical methods as well as systematic studies of the mechanic response of the elastomer end-products towards compression and tensile loading were used to estimate the bio-stability of the prepared TPCUs in vitro after 3 months. The tests suggested that high bio-stability of all polyurethane formulations using accelerating in vitro test can be attributed to the synthetic design as well as to the specific techniques used for specimen preparation, namely: (1) the annealing for reducing residual polymer surface stress and preventing IES, (2) stabilization of the morphology by long time storage of the specimens after processing before being immersed in the test liquids, (3) purification by extraction to remove the shot chain oligomers which are the most susceptible to degradation. All mechanical tests were performed on cylindrical and circular disc specimens for modelling the thickness of the meniscus implants under application-relevant stress conditions.
Age-dependent migratory behavior of human endothelial cells revealed by substrate microtopography
(2019)
Cell migration is part of many important in vivo biological processes and is influenced by chemical and physical factors such as substrate topography. Although the migratory behavior of different cell types on structured substrates has already been investigated, up to date it is largely unknown if specimen's age affects cell migration on structures. In this work, we investigated age-dependent migratory behavior of human endothelial cells from young (≤ 31 years old) and old (≥ 60 years old) donors on poly(dimethylsiloxane) microstructured substrates consisting of well-defined parallel grooves. We observed a decrease in cell migration velocity in all substrate conditions and in persistence length perpendicular to the grooves in cells from old donors. Nevertheless, in comparison to young cells, old cells exhibited a higher cell directionality along grooves of certain depths and a higher persistence time. We also found a systematic decrease of donor age dependent responses of cell protrusions in orientation, velocity and length, all of them decreased in old cells. These observations lead us to hypothesize a possible impairment of actin cytoskeleton network and affected actin polymerization and steering systems, caused by aging.
In Neurofibromatosis 1 (NF1) germ line loss of function mutations result in reduction of cellular neurofibromin content (NF1+/−, NF1 haploinsufficiency). The Ras-GAP neurofibromin is a very large cytoplasmic protein (2818 AA, 319 kDa) involved in the RAS-MAPK pathway. Aside from regulation of proliferation, it is involved in mechanosensoric of cells. We investigated neurofibromin replacement in cultured human fibroblasts showing reduced amount of neurofibromin. Full length neurofibromin was produced recombinantly in insect cells and purified. Protein transduction into cultured fibroblasts was performed employing cell penetrating peptides along with photochemical internalization. This combination of transduction strategies ensures the intracellular uptake and the translocation to the cytoplasm of neurofibromin. The transduced neurofibromin is functional, indicated by functional rescue of reduced mechanosensoric blindness and reduced RasGAP activity in cultured fibroblasts of NF1 patients or normal fibroblasts treated by NF1 siRNA. Our study shows that recombinant neurofibromin is able to revert cellular effects of NF1 haploinsuffiency in vitro, indicating a use of protein transduction into cells as a potential treatment strategy for the monogenic disease NF1.
Surface topographies are often discussed as an important parameter influencing basic cell behavior. Whereas most in vitro studies deal with microstructures with sharp edges, smooth, curved microscale topographies might be more relevant concerning in-vivo situations. Addressing the lack of highly defined surfaces with varying curvature, we present a topography chip system with 3D curved features of varying spacing, curvature radii as well as varying overall dimensions of curved surfaces. The CurvChip is produced by low-cost photolithography with thermal reflow, subsequent (repetitive) PDMS molding and hot embossing. The platform facilitates the systematic in-vitro investigation of the impact of substrate curvature on cell types like epithelial, endothelial, smooth muscle cells, or stem cells. Such investigations will not only help to further understand the mechanism of curvature sensation but may also contribute to optimize cell-material interactions in the field of regenerative medicine.
Analysis of multicellular patterns is required to understand tissue organizational processes. By using a multi-scale object oriented image processing method, the spatial information of cells can be extracted automatically. Instead of manual segmentation or indirect measurements, such as general distribution of contrast or flow, the orientation and distribution of individual cells is extracted for quantitative analysis. Relevant objects are identified by feature queries and no low-level knowledge of image processing is required.
Soft lithography, a tool widely applied in biology and life sciences with numerous applications, uses the soft molding of photolithography-generated master structures by polymers. The central part of a photolithography set-up is a mask-aligner mostly based on a high-pressure mercury lamp as an ultraviolet (UV) light source. This type of light source requires a high level of maintenance and shows a decreasing intensity over its lifetime, influencing the lithography outcome. In this paper, we present a low-cost, bench-top photolithography tool based on ninety-eight 375 nm light-emitting diodes (LEDs). With approx. 10 W, our presented lithography set-up requires only a fraction of the energy of a conventional lamp, the LEDs have a guaranteed lifetime of 1000 h, which becomes noticeable by at least 2.5 to 15 times more exposure cycles compared to a standard light source and with costs less than 850 C it is very affordable. Such a set-up is not only attractive to small academic and industrial fabrication facilities who want to enable work with the technology of photolithography and cannot afford a conventional set-up, but also microfluidic teaching laboratories and microfluidic research and development laboratories, in general, could benefit from this cost-effective alternative. With our self-built photolithography system, we were able to produce structures from 6 μm to 50 μm in height and 10 μm to 200 μm in width. As an optional feature, we present a scaled-down laminar flow hood to enable a dust-free working environment for the photolithography process.
Focal adhesion clusters (FAC) are dynamic and complex structures that help cells to sense physicochemical properties of their environment. Research in biomaterials, cell adhesion or cell migration often involves the visualization of FAC by fluorescence staining and microscopy, which necessitates quantitative analysis of FAC and other cell features in microscopy images using image processing. Fluorescence microscopy images of human umbilical vein endothelial cells (HUVEC) obtained at 63x magnification were quantitatively analysed using ImageJ software. A generalised algorithm for selective segmentation and morphological analysis of FAC, nucleus and cell morphology is implemented. Further, a method for discrimination of FACnear the nucleus and around the periphery is implemented using masks. Our algorithm is able to effectively quantify different morphological characteristics of cell components and shows a high sensitivity and specificity while providing a modular software implementation.
Cell migration plays an essential role in wound healing and inflammatory processes inside the human body. Peripheral blood neutrophils, a type of polymorphonuclear leukocyte (PMN), are the first cells to be activated during inflammation and subsequently migrate toward an injured tissue or infection site. This response is dependent on both biochemical signaling and the extracellular environment, one aspect of which includes increased temperature in the tissues surrounding the inflammation site. In our study, we analyzed temperature-dependent neutrophil migration using differentiated HL-60 cells. The migration speed of differentiated HL-60 cells was found to correlate positively with temperature from 30 to 42 °C, with higher temperatures inducing a concomitant increase in cell detachment. The migration persistence time of differentiated HL-60 cells was higher at lower temperatures (30–33 °C), while the migration persistence length stayed constant throughout the temperature range. Coupled with the increased speed observed at high temperatures, this suggests that neutrophils are primed to migrate more effectively at the elevated temperatures characteristic of inflammation. Temperature gradients exist on both cell and tissue scales. Taking this into consideration, we also investigated the ability of differentiated HL-60 cells to sense and react to the presence of temperature gradients, a process known as thermotaxis. Using a two-dimensional temperature gradient chamber with a range of 27–43 °C, we observed a migration bias parallel to the gradient, resulting in both positive and negative thermotaxis. To better mimic the extracellular matrix (ECM) environment in vivo, a three-dimensional collagen temperature gradient chamber was constructed, allowing observation of biased neutrophil-like differentiated HL-60 migration toward the heat source.
Programmable nano-bio interfaces driven by tuneable vertically configured nanostructures have recently emerged as a powerful tool for cellular manipulations and interrogations. Such interfaces have strong potential for ground-breaking advances, particularly in cellular nanobiotechnology and mechanobiology. However, the opaque nature of many nanostructured surfaces makes non-destructive, live-cell characterization of cellular behavior on vertically aligned nanostructures challenging to observe. Here, a new nanofabrication route is proposed that enables harvesting of vertically aligned silicon (Si) nanowires and their subsequent transfer onto an optically transparent substrate, with high efficiency and without artefacts. We demonstrate the potential of this route for efficient live-cell phase contrast imaging and subsequent characterization of cells growing on vertically aligned Si nanowires. This approach provides the first opportunity to understand dynamic cellular responses to a cell-nanowire interface, and thus has the potential to inform the design of future nanoscale cellular manipulation technologies.
Increasing number of studies are focused on how adherent cells respond, in vitro, to different properties of a material. Typical properties are the surface chemistry, topographical cues (at the nano- and micro-scale) of the surface, and the substrate stiffness. Cell Response studies are of importance for designing new biomaterials with applications in cell culture technologies, regenerative medicine, or for medical implants. However, only very few studies take the cell age factor, respectively the donor age, into account. In this work, we tested two types of human vascular cells (smooth muscle and endothelial cells) from old and young donors on (a) micro-structured surfaces made of pol (dimethylsiloxane) or on (b) flat polyacrylamide hydrogels with varying stiffnesses. These experiments reveal age-dependent and cell typedependent differences in the cell response to the topography and stiffness, and may establish the Basis for further studies focusing on cell age-dependent responses.
In vivo, cells encounter different physical and chemical signals in the extracellular matrix (ECM) which regulate their behavior. Examples of these signals are micro- and nanometer-sized features, the rigidity, and the chemical composition of the ECM. The study of cell responses to such cues is important to understand complex cell functions, some diseases, and is basis for the development of new biomaterials for applications in medical implants or regenerative medicine. Therefore, the development of new methods for surface modifications with controlled physical and chemical features is crucial. In this work, we report a new combination of micelle nanolithography (BCML) and soft micro-lithography, for the production of polyethylene glycol (PEG) hydrogels, with a micro-grooved surface and decoration with hexagonally precisely arranged gold nanoparticles (AU NPs). The Au-NPs are used for binding adhesive ligands in a well-defined density. First tests were performed by culturing human fibroblasts on the gels. Adhesion and alignment of the cells along the parallel grooves of the surface were investigated. The substrates could provide a new platform for studying cell contact guidance by micro structures, and may enable a more precise control of cell behavior by nanometrically controlled surface functionalization.
The extracellular environment of vascular cells in vivo is complex in its chemical composition, physical properties, and architecture. Consequently, it has been a great challenge to study vascular cell responses in vitro, either to understand their interaction with their native environment or to investigate their interaction with artificial structures such as implant surfaces. New procedures and techniques from materials science to fabricate bio-scaffolds and surfaces have enabled novel studies of vascular cell responses under well-defined, controllable culture conditions. These advancements are paving the way for a deeper understanding of vascular cell biology and materials–cell interaction. Here, we review previous work focusing on the interaction of vascular smooth muscle cells (SMCs) and endothelial cells (ECs) with materials having micro- and nanostructured surfaces. We summarize fabrication techniques for surface topographies, materials, geometries, biochemical functionalization, and mechanical properties of such materials. Furthermore, various studies on vascular cell behavior and their biological responses to micro- and nanostructured surfaces are reviewed. Emphasis is given to studies of cell morphology and motility, cell proliferation, the cytoskeleton and cell-matrix adhesions, and signal transduction pathways of vascular cells. We finalize with a short outlook on potential interesting future studies.
Tumorzellen on the move : mikrosystem-basierter Assay zur Untersuchung der Tumorzellen-Migration
(2016)
Die Invasion von Tumorzellen in umliegendes Gewebe und die Bildung von Metastasen transformieren einen lokal wachsenden Tumor in eine systemische und lebensbedrohliche Krankheit mit schlechter Prognose. Dabei spielt die aktive Migration der Tumorzellen eine entscheidende Rolle. Tumorzellen gelangen durch die aktive Zellbewegung in das Lymph- oder Blutsystem und breiten sich im Körper aus. Bei der Invasion in ein neues Organ migrieren die Zellen ebenfalls wieder in komplexer Weise durch das Gewebe und können schließlich dort Metastasen bilden. Auf Grund der enormen medizinischen Relevanz der Tumorzell-Invasion, wird die Bewegung von Tumorzellen seit Jahrzehnten unter Laborbedingungen umfassend untersucht und ist ein wichtiger Marker für die Aggressivität der Tumorzellen. Zur Bewegungsanalyse gibt es mehrere experimentelle und auch kommerziell erhältliche in-vitro Untersuchungsmethoden. Ziel des interdisziplinären Projektes „MigChip“ ist die Entwicklung, Herstellung und experimentelle Validierung eines Mikrofludik-Chips zur verbesserten, detailgenauen in-vitro Untersuchung der Tumorzellen-Migration.
Adapting characteristics of biomaterials specifically for in vitro and in vivo applications is becoming increasingly important in order to control interactions between material and biological systems. These complex interactions are influenced by surface properties like chemical composition, charge, mechanical and topographic attributes. In many cases it is not useful or even not possible to alter the base material but changing surface, to improve biocompatibility or to make surfaces bioactive, may be achieved by thin coatings. An already established method is the coating with polyelectrolyte multilayers (PEM). To adjust adhesion, proliferation and improve vitality of certain cell types, we modified the roughness of PEM coatings. We included different types nanoparticles (NP’s) in different concentrations into PEM coatings for controlling surface roughness. Surface properties were characterized and the reaction of 3 different cell types on these coatings was tested.
Knee osteoarthritis is a common complication and can lead to total loss of joint function in patients. Treatment by either partial or total knee replacement with appropriate UHMWPE based implantsis highly invasive, may cause complications and may show unsatisfying results. Alternatively, treatment may be done by insertion of an elastic interpositional knee spacer with optimized material characteristics.
We report the development of high performance polyurethane-based polymers modified with bioactive molecules for fabrication of such knee spacers. In order to tailor mechanical and tribological properties and to improve resist to enzymatic degradation we propose a core-shell model for the spacer with specifically adapted properties.
Recently described rhizolutin and collinolactone isolated from Streptomyces Gç 40/10 share the same novel carbon scaffold. Analyses by NMR and X-Ray crystallography verify the structure of collinolactone and propose a revision of rhizolutins stereochemistry. Isotope-labeled precursor feeding shows that collinolactone is biosynthesized via type I polyketide synthase with Baeyer–Villiger oxidation. CRISPR-based genetic strategies led to the identification of the biosynthetic gene cluster and a high-production strain. Chemical semisyntheses yielded collinolactone analogues with inhibitory effects on L929 cell line. Fluorescence microscopy revealed that only particular analogues induce monopolar spindles impairing cell division in mitosis. Inspired by the Alzheimerprotective activity of rhizolutin, we investigated the neuroprotective effects of collinolactone and its analogues on glutamate-sensitive cells (HT22) and indeed, natural collinolactone displays distinct neuroprotection from intracellular oxidative stress.
Poly(dimethylsiloxane) can be covalently coated with ultrathin NCO-sP(EO-stat-PO) hydrogel layers which permit covalent binding of cell adhesive moieties, while minimizing unspecific cell adhesion on non-functionalized areas. We applied long term uniaxial cyclic tensile strain (CTS) and revealed (a) the preservation of protein and cell-repellent properties of the NCO-sP(EO-stat-PO) coating and (b) the stability and bioactivity of a covalently bound fibronectin (FN) line pattern. We studied the adhesion of human dermal fibroblast (HDFs) on non-modified NCO-sP(EO-stat-PO) coatings and on the FN. HDFs adhered to FN and oriented their cell bodies and actin fibers along the FN lines independently of the direction of CTS. This mechanical long term stability of the bioactive, patterned surface allows unraveling biomechanical stimuli for cellular signaling and behavior to understand physiological and pathological cell phenomenon. Additionally, it allows for the application in wound healing assays, tissue engineering, and implant development demanding spatial control over specific cell adhesion.