Refine
Document Type
- Conference proceeding (18)
- Journal article (3)
Is part of the Bibliography
- yes (21)
Institute
- Technik (18)
- ESB Business School (3)
Publisher
- VDE Verlag GmbH (21) (remove)
Electronic design automation approaches can roughly be divided into optimizers and procedures. While the former have enabled highly automated synthesis flows for digital integrated circuits, the latter play a vital (but mostly underestimated role) in the analog domain. This paper describes both automation strategies in comparison, identifying two fundamentally different automation paradigms that reflect the two basic design practices known as “top-down” and “bottom-up”. Then, with a focus on the latter, the history of procedural approaches is traced from their
early beginnings until today’s evolvements and future prospects to underline their practical importance and to accentuate their scientific value, both in itself and in the overall context of EDA.
Einpaarige Verkabelungssysteme gewinnen aufgrund des Internets der Dinge und aufgrund deren Einsatz im Automobil- bzw. Industriebereich zunehmend an Bedeutung. Im Rahmen dieser Arbeit wird gezeigt, wie bei der Übertragung über ein einpaariges Kabel die Bitrate bei gleichbleibender Übertragungsbandbreite durch Nutzung des Phantomkreises erhöht werden kann. Als Übertragungsverfahren kommt jeweils eine 16-stufige Pulsamplitudenmodulation zum Einsatz. Die Ergebnisse werden durch Augendiagramme qualitativ und durch die Messung der Symbolfehler bzw. der Bitfehler quantitativ untersucht.
Mit der Überarbeitung der DIN EN 50173 (VDE 0800-173) Serie, wurden unter anderem die optischen Übertragungsstreckenklassen ersatzlos gestrichen. Um die so entstandene Lücke zu schließen, hat das deutsche Gremium DKE GUK 715.3 „Informationstechnische Verkabelung von Gebäudekomplexen“ neue Klassen erarbeitet, die in der DIN VDE 0800- 173-100 „Klassifizierung von Lichtwellenleiter-Übertragungsstrecken“ im Juni 2019 veröffentlicht wurden. Die Norm klassifiziert Lichtwellenleiter Übertragungsstrecken für anwendungsneutrale Kommunikationskabelanlagen nach DIN EN 50173-1.
Sie dient Benutzern, eine breite Palette von Anwendungen zu ermöglichen, die Auswahl des Verkabelungssystems zu erleichtern, eine zukunftssichere Klassifizierung von LWL-Verkabelungen zu generieren und dazu, Systemanforderungen zu beschreiben.
Die in der Norm definierten Klassen beschreiben die Anforderungen an die Übertragungsstrecken und basieren auf einer maximal zulässigen Einfügedämpfung in dB für maximale Übertragungsstreckenlängen, wobei zusätzlich das Bandbreitenlängenprodukt berücksichtigt wird.
Der Beitrag liefert einen Überblick über die Norm und zeigt Anwendungsbeispiele auf.
This paper presents an improvement in usability and integrity of simulation-based analog circuit sizing. Instead of using geometrical sizing parameters (width, length), a transformed design-space, consisting exclusively of electrical parameters (branch currents, efficiencies and speed) is utilized. This design-space is explored more efficiently by optimizers. Moreover, this design-space can be reduced without affecting the quality of the result. The method is illustrated on two application examples, a symmetrical and a miller operational amplifier. Sizing the circuits using the transformed design-space showed significant reduction in required circuit simulations (up to 11x faster), better convergence, without loss in quality.
The current paper proposes a design method for an active damping approach for LC output filters in a power stage for motor control with continuous output voltage. The power stage uses GaN-HEMTs and operates at switching frequencies in a range between 500 kHz and 1MHz. The active damping of the output filter is achieved here by a feedback of the filter inductor current using a high-pass structure. The paper discusses the impact of this feedback on the system behavior and proposes a design method.
Industrielle Produktionseinrichtungen haben mit rund 40% einen signifikanten Anteil am Gesamtenergiebedarf in Deutschland. Daher wurden und werden sie sowohl technologisch als auch energetisch optimiert. Häufig geht die technologischwirtschaftliche Optimierung auch mit der Reduzierung des Energie und Materialverbrauchs einher. Zudem macht der Ausbau der regenerativen Energiequellen die Energieerzeugung zunehmend volatiler, sodass nicht nur die Senkung des absoluten Energieverbrauchs, sondern auch eine höhere Flexibilität (Steuerung der Leistung über der Zeit) zunehmend interessanter wird. Dadurch ändert sich oft die installierte Leistung sowie die Gestaltung der Verlustleistungsabfuhr, was die Dimensionierung von Anlagen, zum Beispiel von spanenden Werkzeugmaschinen, beeinflusst.
Es wird gezeigt, wie bei Fernspeisung die Vorhersage der Erwärmung mit entsprechender Modellierung verbessert werden kann und wie der Einfluss von Material und Form des Kabelkanals die Erwärmung und das das Temperaturprofil des Bündels beeinflusst. Es wird auch vorgestellt, dass die erhöhte Erwärmung von Metallkabelkanälen auf die geringere Emissivität zurückzuführen ist und wie das verbessert werden kann.
Nowadays robust, energy-efficient multisensor microsystems often come with heavily restricted power budgets and the characteristic of remaining in certain states for a longer period of time. During this time frame there is no continuous clock signal required which gives the opportunity to suspend the clock until a new transition is requested. In this paper, we present a new topology for on-demand locally clocked finite state machines. The architecture combines a local adaptive clocking approach with synchronous and asynchronous components forming a quasi synchronous system. Using adaptive and local clocking comes with the advantages of reducing the power consumption while saving design effort when no global clock tree is needed. Combining synchronous and asynchronous components is beneficial compared to previous fully asynchronous approaches concerning the design restrictions. The developed topology is verified by the implementation and simulation of a temperature-ADC sensor system realized in a 180 nm process.
Usually battery chargers have two stages and DC charging current is considered to by necessary for a proper charging. To decrease the charger volume, a single stage LLC battery charger is investigated in this paper. PFC stage is eliminated, therefore no bulky capacitor is necessary any more, and battery is charged with a sinusoidal-like charging current. However, previous studies show that such a pulsating charging current has only minimal impact on battery life and efficiency. Design considerations of the resonant tank and optimal transformer design are presented. A 360W single stage LLC converter prototype for e-bike charger achieves a power factor of 0.98, efficiency of 0.93 and power density of 1,8kW/dm³.