In this work, a brushless, harmonic-excited wound-rotor synchronous machine without any auxiliary windings which can provide full torque at startup is investigated experimentally. The excitation power is transferred inductively by superimposing an additional harmonic field of different pole-pair number on top of the airgap field. This is achieved by feeding the parallel paths of the stator and rotor winding separately. A prototype for the harmonic-excited synchronous machine has been constructed and experimental results are presented to verify the concept. The main loss contributors are identified and the importance of considering core losses under harmonic excitation is discussed. A general analytical model for harmonic excited synchronous machines is proposed which enables a quick estimation of the iron core flux densities and the core losses generated by the additional harmonic currents.
In this work, a comparison between different brushless harmonic-excited wound-rotor synchronous machines is performed. The general idea of all topologies is the elimination of the slip rings and auxiliary windings by using the already existing stator and rotor winding for field excitation. This is achieved by injecting a harmonic airgap field with the help of power electronics. This harmonic field does not interact with the fundamental field, it just transfers the excitation power across the airgap. Alternative methods with varying number of phases, different pole-pair combinations, and winding layouts are covered and compared with a detailed Finite-Element-parameterized model. Parasitic effects due to saturation and coupling between the harmonic and main windings are considered.
In this work, a brushless, harmonic-excited wound-rotor synchronous machine is investigated which utilizes special stator and rotor windings. The windings magnetically decouple the fundamental torque-producing field from the harmonic field required for the inductive power transfer to the field coil. In contrast to conventional harmonic-excited synchronous machines, the whole winding is utilized for both torque production and harmonic excitation such that no additional copper for auxiliary windings is needed. Different rotor topologies using rotating power electronic components are investigated and their efficiencies have been compared based on Finite-Element calculation and circuit analysis.
In this work design rules for a novel brushless excitation system for externally excited synchronous machines are discussed. The concept replaces slip rings with a fullbridge active rectifier and a controller mounted on the rotor. An AC signal induced from the stator is used to charge the rotor DC link. The DC current for the rotor excitation is provided from this DC link source. Finite element analysis of an existing machine is used to analyze the practicability of the excitation system.
A novel brushless excitation concept for synchronous machines with a rotating power converter is proposed in this paper. The concept does not need an auxiliary winding or any other modification to the machine structure apart from an inverter with a DC link capacitor and a controller on the rotor. The power required for the rotor excitation is provided by injecting harmonics into the stator winding. Thus, a voltage in the field coil is induced. The rotor inverter is controlled such that the alternating current charges the DC link capacitor. At the same time the inverter supplies the DC field current to the field coil. The excitation concept is first developed in theory, then presented using an analytical model and FEA, and lastly investigated with a prelimininary experimental setup.
Novel design for a coreless printed circuit board transformer realizing high bandwidth and coupling
(2019)
Rogowski coils offer galvanic isolation and can measure alternating currents with a high bandwidth. Coreless printed circuit board (PCB) transformers have been used as an alternative to limit the additional stray inductance if a Rogowski coil can not be attached to the circuit. A new PCB transformer layout is proposed to reduce cost, decrease additional stray inductance, increase the bandwidth of current measurements and simplify the integration into existing designs.
Improved inductive feed-forward for fast turn-on of power semiconductors during hard switching
(2019)
A transformer is used to increase the gate voltage during turn-on, thus reducing the necessary bias voltage of the gate driver. Counteracting the voltage dependency of the gate capacitance of high-voltage power devices, faster transitions are possible. The additional transformer only slighly increases the over-voltage during turn-off.
The Dual Active Bridge (DAB) is a very promising topology for future power converters. However, careless operation can lead to a DC component in the transformer current. The problem is further exacerbated when the phase shift changes during operation. This work presents a study of DC bias effects on the DAB with special regard to transient effects introduced by sudden shifts in the output load. We present a simple yet effective approach to avoid DC bias entirely.
On-chip metallization, especially in modern integrated BCD technologies, is often subject to high current densities and pronounced temperature cycles due to heat dissipation from power switches like LDMOS transistors. This paper continues the work on a sensor concept where small sense lines are embedded in the metallization layers above the active area of a switching LDMOS transistor. The sensors show a significant resistance change that correlates with the number of power cycles. Furthermore, influences of sense line layer, geometry and the dissipated energy are shown. In this paper, the focus lies on a more detailed analysis of the observed change in sense line resistance.
We present a compact battery charger topology for weight and cost sensitive applications with an average output current of 9A targeted for 36V batteries commonly found in electric bicycles. Instead of using a conventional boost converter with large DC-link capacitors, we accomplish PFC-functionality by shaping the charging current into a sin²-shape. In addition, a novel control scheme without input-current sensing is introduced. A-priori knowledge is used to implement a feed-forward control in combination with a closed-loop output current control to maintain the target current. The use of a full-bridge/half bridge LLC converter enables operation in a wide input-voltage range.
A fully featured prototype has been built with a peak output power of 1050W. An average output power of 400W was measured, resulting in a power density of 1.8 kW/dm³. At 9A charging current, a power factor of 0.96 was measured and the efficiency exceeds 93% on average with passive rectification.
The impact of pulse charging has been evaluated on a 400Wh battery which was charged with the proposed converter as well as CC-CV-charging for reference. Both charging schemes show similar battery surface temperatures.
A novel gate driving approach to balance the transient current of parallel-connected GaN-HEMTs
(2018)
To enable higher current handling capability of GaN-based DC/DC converters, devices have to be used in parallel. However, their switching times differ, especially if their threshold voltages are not identical, which causes unbalanced device current. This paper focuses on the homogeneous distribution of turn-on switching losses of GaN-HEMTs connected in parallel. By applying a new gate driver concept, the transient current is distributed evenly. The effectiveness of this concept is demonstrated by double pulse measurements, for switching currents up to 45A and a voltage of 400V. A uniform current distribution is achieved, including a reduction of the turn-on losses by 50% compared to a conventional setup.
We present a dual active bridge topology suitable for wide voltage range applications covering all combinations of 200V to 600V on the input and 20V to 60V on the output with constant power of 1kW.We employ a stepped inductance scheme to adjust the effective inductance of the converter, thus extending the efficient operation range. Using a variable switching frequency between 35 kHz and 150 kHz with operation-point-dependent limits further increases the performance of the converter. A prototype was built and the proposed changes have been compared to a fixed frequency, fixed inductance implementation. Measurements show a maximum loss reduction of 40 %, leading to a peak efficiency of 97% while maintaining constant output power over the entire working area.
Many GaN power transistors contain a PN junction between gate and the channel region close to the source. In order to maintain the on-state, current must continuously be supplied to the junction. Therefore, the commonly recommended approach uses a gate bias voltage of 12V to compensate the Miller current through a boost circuit. For the same purpose, a novel gate driving method based on an inductive feed forward has been presented. With this, stable turn-on can be achieved even for a bias voltage of only 5V. The effectiveness of this concept is demonstrated by double pulse measurements, switching currents up to 27A and a voltage of 400V. For both approaches a compact design with low source inductance is characterized. In addition to the significant reduction of the gate bias voltage and peak gate current, the new approach reduces the switching losses for load currents >23 A.
This paper presents a control strategy for optimal utilization of photovoltaic (PV) generated power in conjunction with an Energy Storage System (ESS). The ESS is specifically designed to be retrofitted into existing PV systems in an end-user application. It can be attached in parallel to the PV system and connects to existing DC/AC inverters. In particular, the study covers the impact such a modification has on the output power of existing PV panels. A distinct degradation of PV output power was found due to the different power characteristics of PV panel and ESS. To overcome such degradation a novel feedback system is proposed. The feedback system continuously modifies the power characteristic of the ESS to match the PV panel and thus achieves optimal power utilization. Impact on PV and power point tracking performance is analyzed. Simulation of the proposed system is performed in MATLAB/Simulink. The results are found to be satisfactory.
A novel configuration of the dual active bridge (DAB) DC/DC converter is presented, enabling more efficient wide voltage range conversion at light loads. A third phase leg as well as a center tapped transformer are introduced to one side of the converter. This concept provides two different turn ratios, thus extending the zero voltage switching operation resulting in higher efficiency. A laboratory prototype was built converting an input voltage of 40V to an output voltage in the range of 350V to 650V. Measurements show a significant increase up to 20% in the efficiency for light-load operation.
Gallium nitride high electron mobility transistors (GaN-HEMTs) have low capacitances and can achieve low switching losses in applications where hard turn-on is required. Low switching losses imply a fast switching; consequently, fast voltage and current transients occur. However, these transients can be limited by package and layout parasitics even for highly optimized systems. Furthermore, a fast switching requires a fast charging of the input capacitance, hence a high gate current.
In this paper, the switching speed limitations of GaN-HEMTs due to the common source inductance and the gate driver supply voltage are discussed. The turn-on behavior of a GaN-HEMT is simulated and the impact of the parasitics and the gate driver supply voltage on the switching losses is described in detail. Furthermore, measurements are performed with an optimized layout for a drain-source voltage of 500 V and a drain-source current up to 60 A.
Modern power semiconductor devices have low capacitances and can therefore achieve very fast switching transients under hard-switching conditions. However, these transients are often limited by parasitic elements, especially by the source inductance and the parasitic capacitances of the power semiconductor. These limitations cannot be compensated by conventional gate drivers. To overcome this, a novel gate driver approach for power semiconductors was developed. It uses a transformer which accelerates the switching by transferring energy from the source path to the gate path.
Experimental results of the novel gate driver approach show a turn-on energy reduction of 78% (from 80 μJ down to 17 μJ) with a drain-source voltage of 500V and a drain current of 60 A. Furthermore, the efficiency improvement is demonstrated for a hard-switching boost converter. For a switching frequency of 750 kHz with an input voltage of 230V and an output voltage of 400V, it was possible to extend the output power range by 35%(from 2.3kW to 3.1 kW), due to the reduction of the turn-on losses, therefore lowering the junction temperature of the GaN-HEMT.
LDMOS transistors in integrated power technologies are often subject to thermo-mechanical stress, which degrades the on-chip metallization and eventually leads to a short. This paper investigates small sense lines embedded in the LDMOS metallization. It will be shown that their resistance depends strongly on the stress cycle number. Thus, they can be used as aging sensors and predict impending failures. Different test structures have been investigated to identify promising layout configurations. Such sensors are key components for resilient systems that adaptively reduce stress to allow aggressive LDMOS scaling without increasing the risk of failure.
A gate driver approach is presented for the reduction of turn-on losses in hard switching applications. A significant turn-on loss reduction of up to 55% has been observed for SiCMOSFETs. The gate driver approach uses a transformer which couples energy from the power path back into the gate path during switching events, providing increased gate driver current and thereby faster switching speed.
The gate driver approach was tested on a boost converter running at a switching frequency up to 300 kHz. With an input voltage of 300V and an output voltage of 600V, it was possible to reduce the converter losses by 8% at full load. Moreover, the output power range could be extended by 23% (from 2.75kW to 3.4 kW) due to the reduction of the turn-on losses.