Refine
Document Type
- Conference proceeding (52) (remove)
Has full text
- yes (52) (remove)
Is part of the Bibliography
- yes (52)
Institute
- Informatik (51)
- Technik (1)
Publisher
Rapid prototyping platforms reduce development time by allowing quick prototyping of a prototype idea and achieve more time for actual application development with user interfaces. This approach has long been followed in technical platforms, such as the Arduino. To transfer this form of prototyping to wearables, WearIT is presented in this paper.WearIT consists of four components as a wearable prototyping platform: (1) a vest, (2) sensor and actuator shields, (3) its own library and (4) a motherboard consisting of Arduino, Raspberry Pi, a board and a GPS module. As a result, a wearable prototype can be quickly developed by attaching sensor and actuator shields to the WearIT vest. These sensor and actuator shields can then be programmed through the WearIT library. Via Virtual Network Computing (VNC) with a remote computer, the screen contents of the Raspberry Pi can be accessed and the Arduino be programmed.
Being able to monitor the heart activity of patients during their daily life in a reliable, comfortable and affordable way is one main goal of the personalized medicine. Current wearable solutions lack either on the wearing comfort, the quality and type of the data provided or the price of the device. This paper shows the development of a Textile Sensor Platform (TSP) in the form of an electrocardiogram (ECG)-measuring T-shirt that is able to transmit the ECG signal to a smartphone. The development process includes the selection of the materials, the design of the textile electrodes taking into consideration their electrical characteristics and ergonomy, the integration of the electrodes on the garment and their connection with the embedded electronic part. The TSP is able to transmit a real-time streaming of the ECG-signal to an Android smartphone through Bluetooth Low Energy (BLE). Initial results show a good electrical quality in the textile electrodes and promising results in the capture and transmission of the ECG signal. This is still a working- progress and it is the result of an interdisciplinary master project between the School of Informatics and the School of Textiles & Design of the Reutlingen University.
To evaluate the quality of a person´s sleep it is essential to identify the sleep stages and their durations. Currently, the gold standard in terms of sleep analysis is overnight polysomnography (PSG), during which several techniques like EEG (eletroencephalogram), EOG (electrooculogram), EMG (electromyogram), ECG (electrocardiogram), SpO2 (blood oxygen saturation) and for example respiratory airflow and respiratory effort are recorded. These expensive and complex procedures, applied in sleep laboratories, are invasive and unfamiliar for the subjects and it is a reason why it might have an impact on the recorded data. These are the main reasons why low-cost home diagnostic systems are likely to be advantageous. Their aim is to reach a larger population by reducing the number of parameters recorded. Nowadays, many wearable devices promise to measure sleep quality using only the ECG and body-movement signals. This work presents an android application developed in order to proof the accuracy of an algorithm published in the sleep literature. The algorithm uses ECG and body movement recordings to estimate sleep stages. The pre-recorded signals fed into the algorithm have been taken from physionet1 online database. The obtained results have been compared with those of the standard method used in PSG. The mean agreement ratios between the sleep stages REM, Wake, NREM-1, NREM-2 and NREM-3 were 38.1%, 14%, 16%, 75% and 54.3%.
The respiratory rate is a vital sign indicating breathing illness. It is necessary to analyze the mechanical oscillations of the patient's body arising from chest movements. An inappropriate holder on which the sensor is mounted, or an inappropriate sensor position is some of the external factors which should be minimized during signal registration. This paper considers using a non-invasive device placed under the bed mattress and evaluates the respiratory rate. The aim of the work is the development of an accelerometer sensor holder for this system. The normal and deep breathing signals were analyzed, corresponding to the relaxed state and when taking deep breaths. The evaluation criterion for the holder's model is its influence on the patient's respiratory signal amplitude for each state. As a result, we offer a non-invasive system of respiratory rate detection, including the mechanical component providing the most accurate values of mentioned respiratory rate.
A sleep study is a test used to diagnose sleep disorders and is usually done in sleep laboratories. The golden standard for evaluation of sleep is overnight polysomnography (PSG). Unfortunately, in-lab sleep studies are expensive and complex procedures. Furthermore, with a minimum of 22 wire attachments to the patient for sleep recording, this medical procedure is invasive and unfamiliar for the subjects. To solve this problem, low-cost home diagnostic systems, based on noninvasive recording methods requires further researches.
For this intention it is important to find suitable bio vital parameters for classifying sleep phases WAKE, REM, light sleep and deep sleep without any physical impairment at the same time. We decided to analyse body movement (BM), respiration rate (RR) and heart rate variability (HRV) from existing sleep recordings to develop an algorithm which is able to classify the sleep phases automatically. The preliminary results of this project show that BM, RR and HRV are suitable to identify WAKE, REM and NREM stage.
Methods based exclusively on heart rate hardly allow to differentiate between physical activity, stress, relaxation, and rest, that is why an additional sensor like activity/movement sensor added for detection and classification. The response of the heart to physical activity, stress, relaxation, and no activity can be very similar. In this study, we can observe the influence of induced stress and analyze which metrics could be considered for its detection. The changes in the Root Mean Square of the Successive Differences provide us with information about physiological changes. A set of measurements collecting the RR intervals was taken. The intervals are used as a parameter to distinguish four different stages. Parameters like skin conductivity or skin temperature were not used because the main aim is to maintain a minimum number of sensors and devices and thereby to increase the wearability in the future.
Medical applications are becoming increasingly important in the current development of health care and therefore a crucial part of the medical industry. The work focuses on the analysis of requirements and the challenges arisen from designing mobile medical applications in relation to the user interface. The paper describes the current status in the development of mobile medical apps and illustrates the development of e-health market. The author will explain the requirements and will illustrate the hurdles and problems. He refers to the German market which is similar to the European and compares that with the market in the USA.
This document presents an algorithm for a nonobtrusive recognition of Sleep/Wake states using signals derived from ECG, respiration, and body movement captured while lying in a bed. As a core mathematical base of system data analytics, multinomial logistic regression techniques were chosen. Derived parameters of the three signals are used as the input for the proposed method. The overall achieved accuracy rate is 84% for Wake/Sleep stages, with Cohen’s kappa value 0.46. The presented algorithm should support experts in analyzing sleep quality in more detail. The results confirm the potential of this method and disclose several ways for its improvement.
Assistive environments are entering our homes faster than ever. However, there are still various barriers to be broken. One of the crucial points is a personalization of offered services and integration of assistive technologies in common objects and therefore in a regular daily routine. Recognition of sleep patterns for the preliminary sleep study is one of the Health services that could be performed in an undisturbing way. This article proposes the hardware system for the measurement of bio-vital signals necessary for initial sleep study in a nonobtrusive way. The first results confirm the potential of measurement of breathing and movement signals with the proposed system.
Sleep is an important aspect in life of every human being. The average sleep duration for an adult is approximately 7 h per day. Sleep is necessary to regenerate physical and psychological state of a human. A bad sleep quality has a major impact on the health status and can lead to different diseases. In this paper an approach will be presented, which uses a long-term monitoring of vital data gathered by a body sensor during the day and the night supported by mobile application connected to an analyzing system, to estimate sleep quality of its user as well as give recommendations to improve it in real-time. Actimetry and historical data will be used to improve the individual recommendations, based on common techniques used in the area of machine learning and big data analysis.
To assess the quality of a person’s sleep, it is essential to examine the sleep behaviour by identifying the several sleep stages, their durations and sleep cycles. The established and gold standard procedure for sleep stage scoring is overnight polysomnography (PSG) with the Rechtschaffen and Kales (R-K) method. Unfortunately, the conduct of PSG is time-consuming and unfamiliar for the subjects and might have an impact of the recorded data. To avoid the disadvantages with PSG, it is important to make further investigations in low-cost home diagnostic systems. For this intention it is necessary to find suitable bio vital parameters for classifying sleep stages without any physical impairments at the same time. Due to the promising results in several publications we want to analyse existing methods for sleep stage classification based on the parameters body movement,
heartbeat and respiration. Our aim was to find different behaviour patterns in the several sleep stages. Therefore, the average values of 15 whole-night PSG recordings -obtained from the ‘DREAMS
Subjects Database’- where analysed in the light of heartbeat, body movement and respiration with 10 different methods.
Menopause is the permanent cessation of menstruation occurring naturally in women's aging. The most frequent symptoms associated with menopausal phases are mucosal dryness, increased weight and body fat, and changes in sleep patterns. Oral symptoms in menopause derived from saliva flow reduction can lead to dry mouth, ulcers, and alterations of taste and swallowing patterns. However, the oral health phenotype of postmenopausal women has not been characterized. The aim of the study was to determine postmenopausal women's oral phenotype, including medical history, lifestyle, and oral assessment through artificial intelligence algorithms. We enrolled 100 postmenopausal women attending the Dental School of the University of Seville were included in the study. We collected an extensive questionnaire, including lifestyle, medication, and medical history. We used an unsupervised k-means algorithm to cluster the data following standard features for data analysis. Our results showed the main oral symptoms in our postmenopausal cohort were reduced salivary flow and periodontal disease. Relying on the classical assessment of the collected data, we might have a biased evaluation of postmenopausal women. Then, we used artificial intelligence analysis to evaluate our data obtaining the main features and providing a reduced feature defining the oral health phenotype. We found 6 clusters with similar features, including medication affecting salivation or smoking as essential features to obtain different phenotypes. Thus, we could obtain main features considering differential oral health phenotypes of postmenopausal women with an integrative approach providing new tools to assess the women in the dental clinic.
A clinically useful system for individual continuous health data monitoring needs an architecture that takes into account all relevant medical and technical conditions. The requirements for a health app to support such a system are collected, and a vendor independent architecture is designed that allows the collection of vital data from arbitrary wearables using a smartphone. A prototypical implementation for the main scenario shows the feasibility of the approach.
Sleep study can be used for detection of sleep quality and in general bed behaviors. These results can helpful for regulating sleep and recognizing different sleeping disorders of human. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this work is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides, these methods not only decrease practicality due to the process of having to put them on, but they are also very expensive. The system proposed in this paper classifies respiration and body movement with only one type of sensor and also in a noninvasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed excellent results in the classification of breathing rate and body movements.
Sleep analysis using a Polysomnography system is difficult and expensive. That is why we suggest a non-invasive and unobtrusive measurement. Very few people want the cables or devices attached to their bodies during sleep. The proposed approach is to implement a monitoring system, so the subject is not bothered. As a result, the idea is a non-invasive monitoring system based on detecting pressure distribution. This system should be able to measure the pressure differences that occur during a single heartbeat and during breathing through the mattress. The system consists of two blocks signal acquisition and signal processing. This whole technology should be economical to be affordable enough for every user. As a result, preprocessed data is obtained for further detailed analysis using different filters for heartbeat and respiration detection. In the initial stage of filtration, Butterworth filters are used.
Integrating tools and applications into a clinically useful system for individual continuous health data surveillance requires an architecture considering all relevant medical and technical conditions. Therefore, the requirements of an integrated system including a health app to collect and monitor sensor data to support personalized medicine are analyzed. The structure and behavior of the system are defined regarding the specific health use cases and scenarios. A vendor-independent architecture, which enables the collection of vital data from arbitrary wearables using a smartphone, is presented. The data is centrally managed and processed by attending physicians. The modular architecture allows the system to extend to new scenarios, data formats, etc. A prototypical implementation of the system shows the feasibility of the approach.
In the last decades, several driving systems were developed to improve the driving behaviour in energy efficiency or safety. However, these driving systems cover either the area of energy-efficiency or safety. Furthermore, they do not consider the stress level of the driver when showing a recommendation, although stress can lead to an unsafe or inefficient driving behaviour. In this paper, an approach is presented to consider the driver stress level in a driving system for safe and energy-efficient driving behaviour. The driving system tries to suppress a recommendation when the driver is in stress in order not to stress the driver additionally with recommendations in a stressful driving situation. This can lead to an increase in the road safety and in the user acceptance of the driving system, as the driver is not getting bothered or stressed by the driving system.
The evaluation of the approach showed, that the driving system
is able to show recommendations to the driver, while also reacting
to a high stress level by suppressing recommendations in
order not to stress the driver additionally.
Measuring cardiorespiratory parameters in sleep, using non-contact sensors and the Ballistocardiography technique has received much attention due to the low-cost, unobtrusive, and non-invasive method. Designing a user-friendly, simple-to-use, and easy-to-deployment preserving less error-prone remains open and challenging due to the complex morphology of the signal. In this work, using four forcesensitive resistor sensors, we conducted a study by designing four distributions of sensors, in order to simplify the complexity of the system by identifying the region of interest for heartbeat and respiration measurement. The sensors are deployed under the mattress and attached to the bed frame without any interference with the subjects. The four distributions are combined in two linear horizontal, one linear vertical, and one square, covering the influencing region in cardiorespiratory activities. We recruited 4 subjects and acquired data in four regular sleeping positions, each for a duration of 80 seconds. The signal processing was performed using discrete wavelet transform bior 3.9 and smooth level of 4 as well as bandpass filtering. The results indicate that we have achieved the mean absolute error of 2.35 and 4.34 for respiration and heartbeat, respectively. The results recommend the efficiency of a triangleshaped structure of three sensors for measuring heartbeat and respiration parameters in all four regular sleeping positions.