Refine
Year of publication
- 2019 (139) (remove)
Document Type
- Journal article (139) (remove)
Is part of the Bibliography
- yes (139)
Institute
- ESB Business School (59)
- Life Sciences (34)
- Technik (21)
- Informatik (15)
- Texoversum (10)
Publisher
- Elsevier (28)
- De Gruyter (6)
- MDPI (6)
- MIM, Marken-Institut München (6)
- Springer (5)
- Wiley (5)
- Lange (4)
- Thexis Verlag (4)
- ACS (3)
- Emerald (3)
Frost reduction in mechanical balanced ventilation by efficient means of preheating cold supply air
(2019)
This study has focused on evaluating the financial potential of wastewater and geothermal heat recovery systems in a multi-family building. The recovered heat was used to improve the performance of mechanical ventilation with heat recovery (MVHR) system during the coldest days in central Sweden. The main issue, which was targeted with these solutions, was to reduce frost formation in the system and hence increase its thermal efficiency. By looking at the life cycle cost over a lifespan of 20 years, the observed systems were being evaluated economically. Furthermore, statistical analyses were carried-out to counter the uncertainty that comes with the calculation. It was found that the studied wastewater systems have a high possibility of generating savings in this period, while the one fed by geothermal energy is less likely to compensate for its high initial cost. All designed systems however, managed to reduce operational cost by 35-45% due to lower energy usage.
The aim of this work was to investigate the mean fill weight control of a continuous capsule-filling process, whether it is possible to derive controller settings from an appendant process model. To that end, a system composed out of fully automated capsule filler and an online gravimetric scale was used to control the filled weight. This setup allows to examine challenges associated with continuous manufacturing processes, such as variations in the amount of active pharmaceutical ingredient (API) in the mixture due to fluctuations of the feeders or due to altered excipient batch qualities. Two types of controllers were investigated: a feedback control and a combination of feedback and feedforward control. Although both of those are common in the industry, determining the optimal parameter settings remains an issue. In this study, we developed a method to derive the control parameters based on process models in order to obtain optimal control for each filled product. Determined via rapid automated process development (RAPD), this method is an effective and fast way of determining control parameters. The method allowed us to optimize the weight control for three pharmaceutical excipients. By conducting experiments, we verified the feasibility of the proposed method and studied the dynamics of the controlled system. Our work provides important basic data on how capsule filler can be implemented into continuous manufacturing systems.
Most antimicrobial peptides (AMPs) and their synthetic mimics (SMAMPs) are thought to act by permeabilizing cell membranes. For antimicrobial therapy, selectivity for pathogens over mammalian cells is a key requirement. Understanding membrane selectivity is thus essential for designing AMPs and SMAMPs to complement classical antibiotics in the future. This study focuses on membrane permeabilization induced by SMAMPs and their selectivity for membranes with different lipid compositions. We measure release and fluorescence lifetime of a self-quenching dye in lipid vesicles. Apart from the dose-response, we quantify the strength of individual leakage events, and, employing cumulative kinetics, categorize permeabilization behavior. We propose that differing selectivities in a series of SMAMPs arise from a combination of the effect of the antimicrobial agent and the susceptibility of the membrane (with a given lipid composition) for certain types of leakage behavior. The unselective and hemolytic SMAMP is found to act mainly by the asymmetry stress mechanism, mediated by hydrophobic insertion of SMAMPs into lipid layers. The more selective SMAMPs induced leakage events occurring stochastically over several hours. Lipid intrinsic properties might additionally amplify the efficiency of leakage events. Leakage behavior changes with both the design of the SMAMP and the lipid composition of the membrane. Understanding how leakage behavior contributes to the selectivity and activity of antimicrobial agents will aid the design and screening of antimicrobials. An understanding of the underlying processes facilitates the comparison of membrane permeabilization across in vitro and in vivo assays.
Digitalization changes the manufacturing dramatically. In regard of employees’ demands, global trends and the technological vision of future factories, automotive manufacturing faces a huge number of diverse challenges. Currently, research focuses on technological aspects of future factories in terms of digitalization. New ways of work and new organizational models for future factories have not been described yet. There are assumptions on how to develop the organization of work in a future factory but up to now, literature shows deficits in scientifically substantiated answers in this research area. Consequently, the objective of this paper is to present an approach on a work organization design for automotive Industry 4.0 manufacturing. Future requirements were analyzed and deducted to criteria that determine future agile organization design. These criteria were then transformed into functional mechanisms, which define the approach for shopfloor organization design
In spite of many studies, knowledge about the fundamental factors influencing adhesion between addition curing silicones and aluminum substrates is very limited. The aim of this publication is to evaluate the influence of the formulation and the surface state of the adherend on bond strength. For this purpose, the composition of an addition curing silicone was systematically varied and the effects on both material and bond properties were examined. Additionally, the influence of surface aging at different humidities (0% r. h., 34% r. h., 82% r. h.) of acid etch pretreated aluminum substrates was considered. It is shown that the mechanical properties of the silicone material can be easily adjusted over a wide range by changing the formulation. Although high tensile strengths up to 9.2 MPa for the silicone material can be achieved, lap-shear strengths remain moderate at approximately 3.5 MPa. Predominant adhesive failures show the limited adhesive strength of the basic formulation without additives. Basic ingredients of addition curing silicones without additives are able to reach a certain adhesive strength. However, this strength was quite limited and adhesion promoters are required to further improve adhesion. The humidity at which the pretreated substrates are stored has an overall minor influence on bond strength. Surprisingly, bond strength tends to increase with the storage time of aluminum substrates despite lower surface energies in comparison to freshly pretreated substrates. All in all, the storage conditions of aluminum had a rather small influence on adhesion, whereas the composition of the silicone adhesive strongly influences bond strength.
In addition to increased safety by detecting possible overload, continuous component monitoring by sensor integration makes the use of fiber reinforced plastics more cost-effective. Since the components are continuously monitored, one can switch from time-based to condition-based maintenance. However, the integration of conventional sensor components causes weak points, as foreign objects are inserted into the reinforcing structure. In this paper, we examine the use of the textile reinforcement as a sensor in itself. We describe how bending sensors can be formed by slightly modifying in the composite’s reinforcement structure. We investigated two different sensor principles. (1) The integration of textile plate capacitors into the structure; (2) The construction of textile piezo elements as part of the reinforcing structure. The bending test results reveal that textile plate capacitors show a load-dependent signal output. The samples with textile piezo elements show a significant increase in signal strength.
Im Frühjahr 1817 unternahm der damalige Professor Friedrich List an der Universität Tübingen eine Reise nach Frankfurt a. M., wo zu dieser Zeit die berühmte Ostermesse stattfand. Dort traf er mit den Anführern der Kaufleute zusammen, die darüber klagten, dass die zaghafte wirtschaftliche Entwicklung unter den vielen Zollschranken und den Billigimporten aus England stark zu leiden habe. Deshalb forderten sie die Abschaffung der Binnenzölle und die Bildung einer Wirtschaftsunion. Im Auftrag der Kaufleute verfasste List seine berühmt gewordene Petition an die Bundesversammlung, die lose Interessenvertretung des Deutschen Bundes in Frankfurt. Als die Petition mit großem Beifall aufgenommen wurde, gründete List im Hochgefühl seines Erfolges spontan den "Allgemeinen Deutschen Handels- und Gewerbsverein" – die erste Interessenvertretung deutscher Kaufleute. Er legte damit den Grundstein für den politischen Prozess zur Gründung des Zollvereins von 1834, der wiederum die Vorstufe zur Gründung des Deutschen Reiches von 1871 bildete. Lists damalige Forderungen sind zurzeit wieder hoch aktuell.
Exogenous factors of influence on exhaled breath analysis by ion-mobility spectrometry (MCC/IMS)
(2019)
The interpretation of exhaled breath analysis needs to address to the influence of exogenous factors, especially to a transfer of confounding analytes by the test persons. A test person who was exposed to a disinfectant had exhaled breath analysis by MCC/IMS (Bioscout®) after different time intervals. Additionally, a new sampling method with inhalation of synthetic air before breath analysis was tested. After exposure to the disinfectant, 3-Pentanone monomer, 3-Pentanone dimer, Hexanal, 3-Pentanone trimer, 2-Propanamine, 1-Propanol, Benzene, Nonanal showed significantly higher intensities, in exhaled breath and air of the examination room, compared to the corresponding baseline measurements. Only one ingredient of the disinfectant (1-Propanol) was identical to the 8 analytes. Prolonging the time intervals between exposure and breath analysis showed a decrease of their intensities. However, the half-time of the decrease was different. The inhalation of synthetic air - more than consequently airing the examination room with fresh air - reduced the exogenous and also relevant endogenous analytes, leading to a reduction and even changing polarity of the alveolar gradient. The interpretation of exhaled breath needs further knowledge about the former residence of the proband and the likelihood and relevance of the inhalation of local, site-specific and confounding exogenous analytes by him. Their inhalation facilitates a transfer to the examination room and a detection of high concentrations in room air and exhaled breath, but also the exhalation of new analytes. This may lead to a misinterpretation of these analytes as endogenous resp. disease-specific ones.
Standardisation of breath sampling is important for application of breath analysis in clinical settings. By studying the effect of room airing on indoor and breath analytes and by generating time series of room air with different sampling intervals we sought to get further insights into room air metabolism, to detect the relevance of exogenous VOCs and to make conclusions about their consideration for the interpretation of exhaled breath. Room air and exhaled breath of a healthy subject were analysed before and after room airing. Furthermore a time series of room air with doors and windows closed was taken over 84 h by an automatic sampling every 180 min. A second times series studied room air analytes over 70 h with samples taken every 16.5 min. For breath and room air measurements an IMS coupled to a multi-capillary column (IMS/MCC) [Bio-Scout® - B&S Analytik GmbH, Dortmund, Germany] was used. The peaks were characterized using the Software Visual Now (B&S Analytik, Dortmund Germany) and identified using the software package MIMA (version 1.1, provided by the Max Planck Institute for Informatics, Saarbrücken, Germany) and the database 20160426_SubstanzDbNIST_122 (B & S Analytik GmbH, Dortmund, Germany). In the morning 4 analytes (Decamethylcylopentasiloxane [541-02-6]; Pentan-2-one [107-87-9] – Dimer; Hexan-1-al [66-25-1]; Pentan-2-one [107-87-9]) – Monomer showed high intensities in the room air and exhaled breath. They were significantly but not equally reduced by room airing. The time series about 84 h showed a time dependent decrease of analytes (limonen-monomer and -dimer; Decamethylcylopentasiloxane, Butan-1-ol, Butan-1-ol) as well as increase (Pentan-2-one [107-87-9] – Dimer). Shorter sampling intervals exhibited circadian variations of analyte concentrations for many analytes. Breath sampling in the morning needs room airing before starting. Then the variation of the intensity of indoor analytes can be kept small. The time series of indoor analytes show, that their intensities have a different behaviour, with time dependent declines, constant increases and circadian variations, dependent on room airing. This has implications on the breath sampling procedure and the intrepretation of exhaled breath.
Woven piezoelectric sensors as part of the textile reinforcement of fiber reinforced plastics
(2019)
Sensor integration in fiber reinforced plastic (FRP) structures enables online process and structural health monitoring (SHM). This paper describes the development and application of woven fabric-based piezoelectric impact and bending sensors for integration into FRP. The work focuses on design and characterization of woven piezoelectric sensors, especially as a part of the reinforcement structure. The reinforcement of the component acts as a sensor in itself and therefore no additional external objects in the form of sensor components or sensor fibers, which could create unwanted weak points within the FRP, are added. The bending test results reveal a direct relationship between the applied load and the sensor signal. Furthermore, the appropriate sensor position in the component cross section was determined and the influence of thermal polarization on the sensor properties was investigated.