Refine
Year of publication
- 2020 (3) (remove)
Document Type
- Journal article (2)
- Conference proceeding (1)
Has full text
- yes (3)
Is part of the Bibliography
- yes (3)
Institute
- Technik (3)
Publisher
- MDPI (2)
- Technische Universität Graz (1)
Heat pumps are a vital element for reaching the greenhouse gas (GHG) reduction targets in the heating sector, but their system integration requires smart control approaches. In this paper, we first offer a comprehensive literature review and definition of the term control for the described context. Additionally, we present a control approach, which consists of an optimal scheduling module coupled with a detailed energy system simulation module. The aim of this integrated two part control approach is to improve the performance of an energy system equipped with a heat pump, while recognizing the technical boundaries of the energy system in full detail. By applying this control to a typical family household situation, we illustrate that this integrated approach results in a more realistic heat pump operation and thus a more realistic assessment of the control performance, while still achieving lower operational costs.
Bis zum Jahr 2050 soll in Baden Württemberg mit dem Ziel „50-80-90“ der Energiebedarf um 50% reduziert werden, die erneuerbaren Energien sollen zu 80% an der Energieversorgung beteiligt sein und die Emissionen von Treibhausgasen um 90% sinken.Entsprechende Ziele sind für andere Regionen und Länder in ähnlicher Weise festgelegt.
Damit diese Ziele erreicht werden, muss bei der Gebäudewärmeversorgung ein konsequenter Umbau stattfinden. Hier spielt die Sektorenkopplung mit Hilfe von Wärmepumpen (WP) eine entscheidende Rolle. Zur Abschätzung des Potenzials sowie des Aufwandes für einen großflächigen Einsatz von Wärmepumpen ist es unmöglich, eine spezifische und angepasste Dimensionierung der Wärmepumpensysteme für jedes einzelne Gebäude durchzuführen. Stattdessen müssen auf Seiten der Bebauung Referenzgebäude definiert und auf Seiten der Wärmepumpensysteme mittlere Leistungsdaten der am Markt befindlichen Modelle verwendet werden. Während die Festlegung von Referenzgebäuden verschiedentlich in der Literatur zu finden ist, widmet sich der erste Teil der Veröffentlichung der Vorstellung von Korrelationsfunktionen für die thermische und elektrische Leistung sowie die Leistungszahl (COP) von Wärmepumpen, die auf Basis von Herstellerdaten in Abhängigkeit der Quellen- und Vorlauftemperatur ermittelt wurden.
Konkret wurden als Ausgangsbasis für die Korrelationsfunktionen Datenblätter verschiedener Sole- und Luft-Wasser Wärmepumpen (SWP, LWP) zusammengestellt und ausgewertet. Die Grundlage hierfür war die Liste „Wärmepumpen mit Prüfnachweis eines unabhängigen Prüfinstituts“ des Bundesamts für Wirtschaft und Ausfuhrkontrolle (BAFA).
Heat pumps in combination with a photovoltaic system are a very promising option for the transformation of the energy system. By using such a system for coupling the electricity and heat sectors, buildings can be heated sustainably and with low greenhouse gas emissions. This paper reveals a method for dimensioning a suitable system of heat pump and photovoltaics (PV) for residential buildings in order to achieve a high level of (photovoltaic) PV self-consumption. This is accomplished by utilizing a thermal energy storage (TES) for shifting the operation of the heat pump to times of high PV power production by an intelligent control algorithm, which yields a high portion of PV power directly utilized by the heat pump. In order to cover the existing set of building infrastructure, 4 reference buildings with different years of construction are introduced for both single- and multi-family residential buildings. By this means, older buildings with radiator heating as well as new buildings with floor heating systems are included. The simulations for evaluating the performance of a heat pump/PV system controlled by the novel algorithm for each type of building were carried out in MATLAB-Simulink® 2017a. The results show that 25.3% up to 41.0% of the buildings’ electricity consumption including the heat pump can be covered directly from the PV installation per year. Evidently, the characteristics of the heating system significantly influence the results: new buildings with floor heating and low supply temperatures yield a higher level of PV self-consumption due to a higher efficiency of the heat pump compared to buildings with radiator heating and higher supply temperatures. In addition, the effect of adding a battery to the system was studied for two building types. It will be shown that the degree of PV self-consumption increases in case a battery is present. However, due to the high investment costs of batteries, they do not pay off within a reasonable period.