Recent advances in artificial intelligence have enabled promising applications in neurosurgery that can enhance patient outcomes and minimize risks. This paper presents a novel system that utilizes AI to aid neurosurgeons in precisely identifying and localizing brain tumors. The system was trained on a dataset of brain MRI scans and utilized deep learning algorithms for segmentation and classification. Evaluation of the system on a separate set of brain MRI scans demonstrated an average Dice similarity coefficient of 0.87. The system was also evaluated through a user experience test involving the Department of Neurosurgery at the University Hospital Ulm, with results showing significant improvements in accuracy, efficiency, and reduced cognitive load and stress levels. Additionally, the system has demonstrated adaptability to various surgical scenarios and provides personalized guidance to users. These findings indicate the potential for AI to enhance the quality of neurosurgical interventions and improve patient outcomes. Future work will explore integrating this system with robotic surgical tools for minimally invasive surgeries.
Motivation
In order to enable context-aware behavior of surgical assistance systems, the acquisition of various information about the current intraoperative situation is crucial. To achieve this, the complex task of situation recognition can be delegated to a specialized system. Consequently, a standardized interface is required for the seamless transfer of the recognized contextual information to the assistance systems, enabling them to adapt accordingly.
Methods
Our group analyzed four medical interface standards to determine their suitability for exchanging intraoperative contextual information. The assessment was based on a harmonized data and service model derived from the requirements of expected context-aware use cases. The Digital Imaging and Communications in Medicine (DICOM) and IEEE 11073 for Service-oriented Device Connectivity (SDC) were identified as the most appropriate standards.
Results
We specified how DICOM Unified Procedure Steps (UPS), can be used to effectively communicate contextual information. We proposed the inclusion of attributes to formalize different granularity levels of the surgical workflow.
Conclusions
DICOM UPS SOP classes can be used for the exchange of intraoperative contextual information between a situation recognition system and surgical assistance systems. This can pave the way for vendor-independent context awareness in the OR, leading to targeted assistance of the surgical team and an improvement of the surgical workflow.
One of the key challenges for automatic assistance is the support of actors in the operating room depending on the status of the procedure. Therefore, context information collected in the operating room is used to gain knowledge about the current situation. In literature, solutions already exist for specific use cases, but it is doubtful to what extent these approaches can be transferred to other conditions. We conducted a comprehensive literature research on existing situation recognition systems for the intraoperative area, covering 274 articles and 95 cross-references published between 2010 and 2019. We contrasted and compared 58 identified approaches based on defined aspects such as used sensor data or application area. In addition, we discussed applicability and transferability. Most of the papers focus on video data for recognizing situations within laparoscopic and cataract surgeries. Not all of the approaches can be used online for real-time recognition. Using different methods, good results with recognition accuracies above 90% could be achieved. Overall, transferability is less addressed. The applicability of approaches to other circumstances seems to be possible to a limited extent. Future research should place a stronger focus on adaptability. The literature review shows differences within existing approaches for situation recognition and outlines research trends. Applicability and transferability to other conditions are less addressed in current work.
Purpose
Artificial intelligence (AI), in particular deep neural networks, has achieved remarkable results for medical image analysis in several applications. Yet the lack of explainability of deep neural models is considered the principal restriction before applying these methods in clinical practice.
Methods
In this study, we propose a NeuroXAI framework for explainable AI of deep learning networks to increase the trust of medical experts. NeuroXAI implements seven state-of-the-art explanation methods providing visualization maps to help make deep learning models transparent.
Results
NeuroXAI has been applied to two applications of the most widely investigated problems in brain imaging analysis, i.e., image classification and segmentation using magnetic resonance (MR) modality. Visual attention maps of multiple XAI methods have been generated and compared for both applications. Another experiment demonstrated that NeuroXAI can provide information flow visualization on internal layers of a segmentation CNN.
Conclusion
Due to its open architecture, ease of implementation, and scalability to new XAI methods, NeuroXAI could be utilized to assist radiologists and medical professionals in the detection and diagnosis of brain tumors in the clinical routine of cancer patients. The code of NeuroXAI is publicly accessible at https://github.com/razeineldin/NeuroXAI.
Purpose
Context awareness in the operating room (OR) is important to realize targeted assistance to support actors during surgery. A situation recognition system (SRS) is used to interpret intraoperative events and derive an intraoperative situation from these. To achieve a modular system architecture, it is desirable to de-couple the SRS from other system components. This leads to the need of an interface between such an SRS and context-aware systems (CAS). This work aims to provide an open standardized interface to enable loose coupling of the SRS with varying CAS to allow vendor-independent device orchestrations.
Methods
A requirements analysis investigated limiting factors that currently prevent the integration of CAS in today's ORs. These elicited requirements enabled the selection of a suitable base architecture. We examined how to specify this architecture with the constraints of an interoperability standard. The resulting middleware was integrated into a prototypic SRS and our system for intraoperative support, the OR-Pad, as exemplary CAS for evaluating whether our solution can enable context-aware assistance during simulated orthopedical interventions.
Results
The emerging Service-oriented Device Connectivity (SDC) standard series was selected to specify and implement a middleware for providing the interpreted contextual information while the SRS and CAS are loosely coupled. The results were verified within a proof of concept study using the OR-Pad demonstration scenario. The fulfillment of the CAS’ requirements to act context-aware, conformity to the SDC standard series, and the effort for integrating the middleware in individual systems were evaluated. The semantically unambiguous encoding of contextual information depends on the further standardization process of the SDC nomenclature. The discussion of the validity of these results proved the applicability and transferability of the middleware.
Conclusion
The specified and implemented SDC-based middleware shows the feasibility of loose coupling an SRS with unknown CAS to realize context-aware assistance in the OR.
Purpose
Supporting the surgeon during surgery is one of the main goals of intelligent ORs. The OR-Pad project aims to optimize the information flow within the perioperative area. A shared information space should enable appropriate preparation and provision of relevant information at any time before, during, and after surgery.
Methods
Based on previous work on an interaction concept and system architecture for the sterile OR-Pad system, we designed a user interface for mobile and intraoperative (stationary) use, focusing on the most important functionalities like clear information provision to reduce information overload. The concepts were transferred into a high-fidelity prototype for demonstration purposes. The prototype was evaluated from different perspectives, including a usability study.
Results
The prototype’s central element is a timeline displaying all available case information chronologically, like radiological images, labor findings, or notes. This information space can be adapted for individual purposes (e.g., highlighting a tumor, filtering for own material). With the mobile and intraoperative mode of the system, relevant information can be added, preselected, viewed, and extended during the perioperative process. Overall, the evaluation showed good results and confirmed the vision of the information system.
Conclusion
The high-fidelity prototype of the information system OR-Pad focuses on supporting the surgeon via a timeline making all available case information accessible before, during, and after surgery. The information space can be personalized to enable targeted support. Further development is reasonable to optimize the approach and address missing or insufficient aspects, like the holding arm and sterility concept or new desired features.
Purpose: Gliomas are the most common and aggressive type of brain tumors due to their infiltrative nature and rapid progression. The process of distinguishing tumor boundaries from healthy cells is still a challenging task in the clinical routine. Fluid attenuated inversion recovery (FLAIR) MRI modality can provide the physician with information about tumor infiltration. Therefore, this paper proposes a new generic deep learning architecture, namely DeepSeg, for fully automated detection and segmentation of the brain lesion using FLAIR MRI data.
Methods: The developed DeepSeg is a modular decoupling framework. It consists of two connected core parts based on an encoding and decoding relationship. The encoder part is a convolutional neural network (CNN) responsible for spatial information extraction. The resulting semantic map is inserted into the decoder part to get the full-resolution probability map. Based on modified U-Net architecture, different CNN models such as residual neural network (ResNet), dense convolutional network (DenseNet), and NASNet have been utilized in this study.
Results: The proposed deep learning architectures have been successfully tested and evaluated on-line based on MRI datasets of brain tumor segmentation (BraTS 2019) challenge, including s336 cases as training data and 125 cases for validation data. The dice and Hausdorff distance scores of obtained segmentation results are about 0.81 to 0.84 and 9.8 to 19.7 correspondingly.
Conclusion: This study showed successful feasibility and comparative performance of applying different deep learning models in a new DeepSeg framework for automated brain tumor segmentation in FLAIR MR images. The proposed DeepSeg is open source and freely available at https://github.com/razeineldin/DeepSeg/.
Accurate and safe neurosurgical intervention can be affected by intra-operative tissue deformation, known as brain-shift. In this study, we propose an automatic, fast, and accurate deformable method, called iRegNet, for registering pre-operative magnetic resonance images to intra-operative ultrasound volumes to compensate for brain-shift. iRegNet is a robust end-to-end deep learning approach for the non-linear registration of MRI-iUS images in the context of image-guided neurosurgery. Pre-operative MRI (as moving image) and iUS (as fixed image) are first appended to our convolutional neural network, after which a non-rigid transformation field is estimated. The MRI image is then transformed using the output displacement field to the iUS coordinate system. Extensive experiments have been conducted on two multi-location databases, which are the BITE and the RESECT. Quantitatively, iRegNet reduced the mean landmark errors from pre-registration value of (4.18 ± 1.84 and 5.35 ± 4.19 mm) to the lowest value of (1.47 ± 0.61 and 0.84 ± 0.16 mm) for the BITE and RESECT datasets, respectively. Additional qualitative validation of this study was conducted by two expert neurosurgeons through overlaying MRI-iUS pairs before and after the deformable registration. Experimental findings show that our proposed iRegNet is fast and achieves state-of-the-art accuracies outperforming state-of-the-art approaches. Furthermore, the proposed iRegNet can deliver competitive results, even in the case of non-trained images as proof of its generality and can therefore be valuable in intra-operative neurosurgical guidance.
Zur Unterstützung des Operateurs wird eine patientennahe Informationsanzeige entwickelt, die kontextrelevante Informationen entsprechend der aktuellen Situation bereitstellen kann. Hierfür soll eine Situationserkennung konzipiert werden, die auf unterschiedliche intraoperative Prozesse übertragen werden kann. Ziel der adaptiven Situationserkennung ist das Erkennen spezifischer Situationen durch intraoperative Informationen unterschiedlicher Datenquellen im Operationssaal. Innerhalb der Datenerhebung und -analyse wurden Anwendungsfälle für die Situationserkennung definiert sowie chirurgische Prozessmodelle erstellt, die intraoperative Ereignisse abbilden. Auf Basis dieser Informationen wurde ein Konzept entworfen, das sich zunächst auf die Erkennung abstrakter generalisierter Phasen, unabhängig vom Eingriff, fokussiert und sich Schritt für Schritt auf granulare Prozessschritte spezifizieren lässt. Diese Flexibilität soll die Übertragbarkeit des Konzepts auf intraoperative Prozesse ermöglichen und den Operateur dadurch gezielt mit kontextrelevanten Informationen unterstützen. Das Konzept wird in zukünftigen Schritten weiterentwickelt.
Workflow driven support systems in the peri-operative area have the potential to optimize clinical processes and to allow new situation-adaptive support systems. We started to develop a workflow management system supporting all involved actors in the operating theatre with the goal to synchronize the tasks of the different stakeholders by giving relevant information to the right team members. Using the OMG standards BPMN, CMMN and DMN gives us the opportunity to bring established methods from other industries into the medical field. The system shows each addressed actor their information in the right place at the right time to make sure every member can execute their task in time to ensure a smooth workflow. The system has the overall view of all tasks. Accordingly, a workflow management system including the Camunda BPM workflow engine to run the models, and a middleware to connect different systems to the workflow engine and some graphical user interfaces to show necessary information or to interact with the system are used. The complete pipeline is implemented with a RESTful web service. The system is designed to include different systems like hospital information system (HIS) via the RESTful web service very easily and without loss of data. The first prototype is implemented and will be expanded.
Multi-dimensional patient data, such as time varying volume data, data of different imaging modalities, surface segmentations etc. are of growing importance in the clinical routine. For many use cases, it is of major importance to replicate a certain visualization of a data set created on one machine on a different computer using different software tools. Up until now, there exists no standardized methodology for this consistent presentation. We propose an extension of the Digital Imaging und Communications in Medicine (DICOM) called “Multi dimensional Presentation State” and outline scope and first results of the standardization process.
Radiofrequency ablation is an ablation technique to treat tumors with focused heat. Computer tomography, ultrasound and magnetic resonance imaging (MRI) are imaging modalities which can be used for image-guided procedures. MRI offers several advantages in comparison to the other imaging modalities, such as radiation-free fluoroscopic imaging, temperature mapping, a high-soft-tissue contrast and free selection of imaging planes. This work addresses the application of 3Dcontrollers for controlling interventional, fluoroscopic MR sequences at the scenario of MR guided radiofrequency ablation of hepatic malignancies. During this procedure, the interventionalist can monitor the targeting of the tumor with near-real time fluoroscopic sequences. In general, adjustments of the imaging planes are necessary during tumor targeting, which is performed by an assistant in the control room. Therefore, communication between the interventionalist in the scanner room and the assistant in the control room is essential. However, verbal communication is impaired due to the loud scanning noises. Alternatively, non-verbal communication between the two persons is possible, however limited to a few gestures and susceptible to misunderstandings. This work is analyzing different 3D-controllers to enable control of interventional MR sequences during MR-guided procedures directly by the interventionalist. Leap Motion, Wii Remote, SpaceNavigator, Phantom Omni and Foot Switch were selected. For that a simulation was built in C++ with VTK to feign the real scenario for test purposes. Previous results showed that Leap Motion is not suitable for the application while Wii Remote and Foot Switch are possible input devices. Final evaluation showed a generally time reduction with the use of 3D-controllers. Best results were reached with Wii Remote in 34 seconds. Handholding input devices like Wii Remote have further potential to integrate them in real environment to reduce intervention time.
Die DGCH registriert vermehrt Klagen aus der klinischen Praxis hinsichtlich der nicht vollständigen Vernetzung bzw. Integration von Gerätesystemen im Chirurgischen OP. Die Anzahl, der Funktionsumfang und der Komplexitätsgrad der verwendeten Geräte nehmen ständig zu und machen die Bedienung immer aufwendiger und damit schwieriger und fehleranfälliger, sodass eine Verbesserung bei der Unterstützung im Ablauf wünschenswert ist. Die Sektion Computer- und telematikassistierte Chirurgie (CTAC) der DGCH hat es auf Veranlassung des Generalsekretärs deshalb übernommen, eine aktuelle Bestandsaufnahme vorzunehmen und mögliche Ansätze zur Verbesserung des derzeitigen Status zu bewerten.
Die minimal-invasive Chirurgie (MIC) entwickelt sich durch den Einsatz von medizinischen Robotern wie dem da Vinci System von Intuitive Surgical stetig weiter. Hierdurch kann eine bessere oder gleichwertige Operation bei deutlich geringerer körperlicher Belastung des Operateurs erreicht werden. Dabei entstehen jedoch neue Problemstellungen wie beispielsweise Kollision zwischen Roboterarmen und die benötigte Zeit zum Einrichten einer geeigneten Roboterkonfiguration. Daher ist eine effiziente Vorbereitung und Planung der Interventionen erforderlich. Diese Arbeit präsentiert einen Ansatz für eine verbesserte Planung mit Augmented Reality (AR) und einer Robotik Simulationssoftware (RS). Die Robotik Simulation dient zur Berechnung einer Roboterkonfiguration unter Vorgabe der Port-Positionen. Augmented Reality wird verwendet, um die berechneten Pose in der realen Umgebung zu visualisieren und somit leichter in den Operationssaal zu übertragen.
In der Orthopädie werden Robotersysteme bereits seit mehreren Jahren erfolgreich unterstützend eingesetzt. Dieser Ansatz erfordert die vorgelagerte Erstellung eines digitalen Modells auf Basis von medizinischen Bilddatensätzen. Die Erstellung und Überprüfung der Modelle soll in einer browserbasierten Client- Server-Anwendung erfolgen. Hierfür ist die Darstellung von zweidimensionalen und dreidimensionalen Datensätzen erforderlich. Basis dieses Papers ist die Entwicklung eines Ansatzes zur interaktiven, browserbasierten dreidimensionalen Darstellung medizinischer Planungsdaten. Die Anwendung stellt ein Proof of Concept dar, ob die bestehenden Desktopanwendungen zur Darstellung von Planungsdaten ersetzt werden können. Mit Hilfe des Frameworks AMI.js wurde die Anwendung umgesetzt. Sie erfüllt alle definierten Anforderungen und kann somit die aktuellen Desktopanwendungen ersetzen.
An operation room is a stressful work environment. Nevertheless, all involved persons have to work safely as there is no space for making mistakes. To ensure a high level of concentration and seamless interaction, all involved persons have to know their own tasks and tasks of their colleagues. The entire team must work synchronously at all times. However, the operation room (OR) is a noisy environment and the actors have to set their focus on their work. To optimize the overall workflow, a task manager supporting the team was developed. Each actor is equipped with a client terminal showing a summary of their own tasks. Moreover, a big screen displays all tasks of all actors. The architecture is a distributed system based on a communication framework that supports the interaction of all clients with the task manager. A prototype of the task manager and several clients have been developed and implemented. The system represents a proof-of-concept for further development. This paper describes the concept of the task manager.
This study is about estimating the reproducibility of finding palpation points of three different anatomical landmarks in the human body (Xiphoid Process and the 2 Hip Crests) to support a navigated ultrasound application. On 6 test subjects with different body mass index the three palpation points were located five times by two examiners. The deviation from the target position was calculated and correlated to the fat thickness above each palpation point. The reproducibility of the measurements had a mean error of ≈13.5 mm +- 4 mm, which seems to be sufficient for the desired application field.
Documentation of clinical processes, especially in the perioperative are, is a base requirement for quality of service. Nonetheless, the documentation is a burden for the medical staff since it distracts from the clinical core process. An intuitive and user-friendly documentation system could increase documentation quality and reduce documentation workload. The optimal system solution would know what happened and the person documenting the step would need a single “confirm” button. In many cases, such a linear flow of activities is given as long as only one profession (e.g. anaestesiology, scrub nurse) is considered, but even in such cases, there might be derivations from the linear process flow and further interaction is required.
Die Segmentierung und das Tracking von minimal-invasiven robotergeführten Instrumenten ist ein wesentlicher Bestandteil für verschiedene computer assistierte Eingriffe. Allerdings treten in der minimal-invasiven Chirurgie, die das Anwendungsfeld für den hier beschriebenen Ansatz darstellt, häufig Schwierigkeiten durch Reflexionen, Schatten oder visuelle Verdeckungen durch Rauch und Organe auf und erschweren die Segmentierung und das Tracking der Instrumente.
Dieser Beitrag stellt einen Deep Learning Ansatz für ein markerloses Tracking von minimal-invasiven Instrumenten vor und wird sowohl auf simulierten als auch realen Daten getestet. Es wird ein simulierter als auch realer Datensatz mit Ground Truth Kennzeichnung für die binäre Segmentierung von Instrument und Hintergrund erstellt. Für den simulierten Datensatz werden Bilder aus einem simulierten Instrument und realem Hintergrund zusammengesetzt. Im Falle des realen Datensatzes spricht man von der Zusammensetzung der Bilder aus einem realen Instrument und Hintergrund. Insgesamt wird auf den simulierten Daten eine Pixelgenauigkeit von 94.70 Prozent und auf den realen Daten eine Pixelgenauigkeit von 87.30 Prozent erreicht.
Informationstechnische Systeme, die den Arbeitsablauf im klinischen Bereich unterstützen, sind aktuell auf organisatorische Abläufe beschränkt. Diese Arbeit stellt einen ersten Ansatz vor, wie solch ein System in den perioperativen Bereich eingebracht werden kann. Hierzu wurde eine Workflow Engine mit einer perioperativen Prozess-Visualisierung verknüpft. Das System wurde nach Modell-View-Controller-Prinzip implementiert. Als "Controller" kommt die Workflow Engine zum Einsatz; also "Modell" ein Prozessmodell, mit den erforderlichen klinischen Daten. Der "View" wurde durch eine abgekoppelte Anwendung realisiert, welche auf Web-Technologien basiert. Drei Visualisierungen, die Workflow Engine sowie die Anbindung beider über eine Datenbankschnittstelle, wurden erfolgreich umgesetzt. Bei den drei Visualisierungen wurden jeweils eine Ansicht für den OP-Koordinator, den Springer und eine Ansicht für die Übersicht einer OP erstellt.