Automatic segmentation is essential for the brain tumor diagnosis, disease prognosis, and follow-up therapy of patients with gliomas. Still, accurate detection of gliomas and their sub-regions in multimodal MRI is very challenging due to the variety of scanners and imaging protocols. Over the last years, the BraTS Challenge has provided a large number of multi-institutional MRI scans as a benchmark for glioma segmentation algorithms. This paper describes our contribution to the BraTS 2022 Continuous Evaluation challenge. We propose a new ensemble of multiple deep learning frameworks namely, DeepSeg, nnU-Net, and DeepSCAN for automatic glioma boundaries detection in pre-operative MRI. It is worth noting that our ensemble models took first place in the final evaluation on the BraTS testing dataset with Dice scores of 0.9294, 0.8788, and 0.8803, and Hausdorf distance of 5.23, 13.54, and 12.05, for the whole tumor, tumor core, and enhancing tumor, respectively. Furthermore, the proposed ensemble method ranked first in the final ranking on another unseen test dataset, namely Sub-Saharan Africa dataset, achieving mean Dice scores of 0.9737, 0.9593, and 0.9022, and HD95 of 2.66, 1.72, 3.32 for the whole tumor, tumor core, and enhancing tumor, respectively.
This project aims to evaluate existing big data infrastructures for their applicability in the operating room to support medical staff with context-sensitive systems. Requirements for the system design were generated. The project compares different data mining technologies, interfaces, and software system infrastructures with a focus on their usefulness in the peri-operative setting. The lambda architecture was chosen for the proposed system design, which will provide data for both postoperative analysis and real-time support during surgery.
Introduction: Even if there is a standard procedure of CI surgery, especially in pediatric surgery surgical steps often differ individually due to anatomical variations, malformations or unforseen events. This is why every surgical report should be created individually, which takes time and relies on the correct memory of the surgeon. A standardized recording of intraoperative data and subsequent storage as well as text processing would therefore be desirable and provides the basis for subsequent data processing, e.g. in the context of research or quality assurance.
Method: In cooperation with Reutlingen University, we conducted a workflow analysis of the prototype of a semi-automatic checklist tool. Based on automatically generated checklists generated from BPMN models a prototype user interface was developed for an android tablet. Functions such as uploading photos and files, manual user entries, the interception of foreseeable deviations from the normal course of operations and the automatic creation of OP documentation could be implemented. The system was tested in a remote usability test on a petrous bone model.
Result: The user interface allows a simple intuitive handling, which can be well implemented in the intraoperative setting. Clinical data as well as surgical steps could be individually recorded and saved via DICOM. An automatic surgery report could be created and saved.
Summary: The use of a dynamic checklist tool facilitates the capture, storage and processing of surgical data. Further applications in clinical practice are pending.
Motivation
In order to enable context-aware behavior of surgical assistance systems, the acquisition of various information about the current intraoperative situation is crucial. To achieve this, the complex task of situation recognition can be delegated to a specialized system. Consequently, a standardized interface is required for the seamless transfer of the recognized contextual information to the assistance systems, enabling them to adapt accordingly.
Methods
Our group analyzed four medical interface standards to determine their suitability for exchanging intraoperative contextual information. The assessment was based on a harmonized data and service model derived from the requirements of expected context-aware use cases. The Digital Imaging and Communications in Medicine (DICOM) and IEEE 11073 for Service-oriented Device Connectivity (SDC) were identified as the most appropriate standards.
Results
We specified how DICOM Unified Procedure Steps (UPS), can be used to effectively communicate contextual information. We proposed the inclusion of attributes to formalize different granularity levels of the surgical workflow.
Conclusions
DICOM UPS SOP classes can be used for the exchange of intraoperative contextual information between a situation recognition system and surgical assistance systems. This can pave the way for vendor-independent context awareness in the OR, leading to targeted assistance of the surgical team and an improvement of the surgical workflow.
Physicians in interventional radiology are exposed to high physical stress. To avoid negative long-term effects resulting from unergonomic working conditions, we demonstrated the feasibility of a system that gives feedback about unergonomic
situations arising during the intervention based on the Azure Kinect camera. The overall feasibility of the approach could be shown.
Motivation: Aim of this project is the automatic classification of total hip endoprosthesis (THEP) components in 2D Xray images. Revision surgeries of total hip arthroplasty (THA) are common procedures in orthopedics and trauma surgery. Currently, around 400.000 procedures per year are performed in the United States (US) alone. To achieve the best possible result, preoperative planning is crucial. Especially if parts of the current THEP system are to be retained.
Methods: First, a ground truth based on 76 X-ray images was created: We used an image processing pipeline consisting of a segmentation step performed by a convolutional neural network and a classification step performed by a support vector machine (SVM). In total, 11 classes (5 pans and 6 shafts) shall be classified.
Results: The ground truth generated was of good quality even though the initial segmentation was performed by technicians. The best segmentation results were achieved using a U-net architecture. For classification, SVM architectures performed much better than additional neural networks.
Conclusions: The overall image processing pipeline performed well, but the ground truth needs to be extended to include a broader variability of implant types and more examples per training class.
Glioblastomas are the most aggressive fast-growing primary brain cancer which originate in the glial cells of the brain. Accurate identification of the malignant brain tumor and its sub-regions is still one of the most challenging problems in medical image segmentation. The Brain Tumor Segmentation Challenge (BraTS) has been a popular benchmark for automatic brain glioblastomas segmentation algorithms since its initiation. In this year, BraTS 2021 challenge provides the largest multi-parametric (mpMRI) dataset of 2,000 pre-operative patients. In this paper, we propose a new aggregation of two deep learning frameworksnamely, DeepSeg and nnU-Net for automatic glioblastoma recognition in pre-operative mpMRI. Our ensemble method obtains Dice similarity scores of 92.00, 87.33, and 84.10 and Hausdorff Distances of 3.81, 8.91, and 16.02 for the enhancing tumor, tumor core, and whole tumor regions, respectively, on the BraTS 2021 validation set, ranking us among the top ten teams. These experimental findings provide evidence that it can be readily applied clinically and thereby aiding in the brain cancer prognosis, therapy planning, and therapy response monitoring. A docker image for reproducing our segmentation results is available online at (https://hub.docker.com/r/razeineldin/deepseg21).
What might the attendee be able to do after being in your session?
Our work shows how to connect intra-operative devices via IEEE 11073 Service-oriented Device Connectivity (SDC).
Description of the Problem or Gap
Standardized device communication is essential for interoperability, availability of device data, and therefore for the intelligent operating room (OR) and arising solutions. The SDC standard was developed to make information from medical devices available in a uniform manner and enable interoperability. Existing devices are rarely SDC-capable and need interfaces to be interoperable via SDC.
Methods: What did you do to address the problem or gap?
We conceived an SDC-based architecture consisting of a service provider and service consumer. In our concept, the service provider is connected to the medical device and capable to translate the proprietary protocol of the device into SDC and vice versa. The service consumer is used to request or send information via the SDC protocol to the service provider and can function as a uniform bidirectional interface (e.g. for displaying or controlling). This concept was exemplarily demonstrated with the patient monitor MX800 of Philips to retrieve the device data (e.g. vital parameters) via SDC and partly for the operating light marLED X of KLS Martin Group.
Results: What was the outcome(s) of what you did to address the problem or gap?
The patient monitor MX800 was connected to a Raspberry Pi (RPi) via LAN, on which the service provider is running. The python script on the RPi establishes a connection to the monitor and translates incoming and outgoing messages from the proprietary protocol to SDC and vice versa to/from the service consumer. The service consumer is running on a laptop and acts as a simulation for different kinds of systems that want to get vital parameters or other information from the patient monitor. The operating light marLED X was connected to an RPi via USB-to-RS232. A python script on the RPi establishes a connection to the light and makes it possible via proprietary commands to get information of the light (e.g. status) and to control it (e.g. toggle the light, increment the intensity). A translation to SDC is not integrated yet.
Discussion of Results
Our practical implementation shows that medical devices can be accessed via external connections to get device data and control the device via commands. The example SDC implementation of the patient monitor MX800 makes it possible to request its data via the standardized communication protocol SDC. This is also possible for the operating light marLED X if its proprietary protocol is analyzed to be translatable to/from SDC. This would allow to control the device from an external system, or automatically depending on the status of the ongoing procedure. The advantage is, that existing intra-operative devices can be extended by a service provider which is capable of translating the proprietary protocol of the device in SDC and vice versa. This enables interoperability and an intelligent OR that, for example, is aware of all devices, their status, and data and can use this information to optimally support the surgeons and their team (e.g. provision of information, automated documentation). This interoperability allows that future innovations merely need to understand the SDC protocol instead of all vendor-dependent communication protocols.
Conclusion
Standardized device communication is essential to reach interoperability, and therefore intelligent ORs. Our contribution addresses the possibility of subsequently making medical devices SDC-capable. This may eliminate the need of understanding all the different proprietary protocols when developing new innovative solutions for the OR.
Purpose
Artificial intelligence (AI), in particular deep learning (DL), has achieved remarkable results for medical image analysis in several applications. Yet the lack of human-like explanations of such systems is considered the principal restriction before utilizing these methods in clinical practice (Yang, Ye, & Xia, 2022).
Methods
Explainable Artificial Intelligence (XAI) provides a human-explainable and interpretable description of the “black-box” nature of DL (Gulum, Trombley, & Kantardzic, 2021). An effective XAI diagnosis generator, namely NeuroXAI (refer to Fig. 1), has been developed to extract 3D explanations from convolutional neural networks (CNN) models of brain gliomas (Zeineldin et al., 2022). By providing visual justification maps, NeuroXAI can help make DL models transparent and thus increase the trust of medical experts.
Results
NeuroXAI has been applied to two applications of the most widely investigated problems in brain imaging analysis, i.e. image classification and segmentation using magnetic resonance imaging (MRI). Visual attention maps of multiple XAI methods have been generated and compared for both applications, which could help to provide transparency about the performance of DL systems.
Conclusion
NeuroXAI helps to understand the prediction process of 3D CNN networks for brain glioma using human-understandable explanations. Results revealed that the investigated DL models behave in a logical human-like manner and can improve the analytical process of the MRI images systematically. Due to its open architecture, ease of implementation, and scalability to new XAI methods, NeuroXAI could be utilized to assist medical professionals in the detection and diagnosis of brain tumors. NeuroXAI code is publicly accessible at https://github.com/razeineldin/NeuroXAI
Die Bereitstellung klinischer Informationen im Operationssaal ist ein wichtiger Aspekt zur Unterstützung des chirurgischen Teams. Die roboter-assistierte Ösophagusresektion ist ein besonders komplexer Eingriff, der Potenzial zur workflowbasierten Unterstützung bietet. Wir präsentieren erste Ergebnisse der Entwicklung eines Checklisten-Tools mit der zugrundeliegenden Modellierung des chirurgischen Workflows und Informationsbedarf der Chirurgen. Das Checklisten-Tool zeigt hierfür die durchzuführenden Schritte chronologisch an und stellt zusätzliche Informationen kontextadaptiert bereit. Eine automatische Dokumentation von Start- und Endzeiten einzelner OP-Phasen und Schritte soll zukünftige Prozessanalysen der Operation ermöglichen.
A hybrid deep registration of MR scans to interventional ultrasound for neurosurgical guidance
(2021)
Despite the recent advances in image-guided neurosurgery, reliable and accurate estimation of the brain shift still remains one of the key challenges. In this paper, we propose an automated multimodal deformable registration method using hybrid learning-based and classical approaches to improve neurosurgical procedures. Initially, the moving and fixed images are aligned using classical affine transformation (MINC toolkit), and then the result is provided to the convolutional neural network, which predicts the deformation field using backpropagation. Subsequently, the moving image is transformed using the resultant deformation into a moved image. Our model was evaluated on two publicly available datasets: the retrospective evaluation of cerebral tumors (RESECT) and brain images of tumors for evaluation (BITE). The mean target registration errors have been reduced from 5.35 ± 4.29 to 0.99 ± 0.22 mm in the RESECT and from 4.18 ± 1.91 to 1.68 ± 0.65 mm in the BITE. Experimental results showed that our method improved the state-of-the-art in terms of both accuracy and runtime speed (170 ms on average). Hence, the proposed method provides a fast runtime for 3D MRI to intra-operative US pair in a GPU-based implementation, which shows a promise for its applicability in assisting the neurosurgical procedures compensating for brain shift.
In networked operating room environments, there is an emerging trend towards standardized non-proprietary communication protocols which allow to build new integration solutions and flexible human-machine interaction concepts. The most prominent endeavor is the IEEE 11073 SDC protocol. For some uses cases, it would be helpful if not just medical devices could be controlled based on SDC, but also building automation systems like light, shutters, air condition, etc. For those systems, the KNX protocol is widely used. We build an SDC-to-KNX gateway which allows to use the SDC protocol for sending commands to connected KNX devices. The first prototype system was successfully implemented at the demonstration operating room at Reutlingen University. This is a first step toward the integration of a broader variety of KNX devices.
Documentation of clinical processes, especially in the perioperative are, is a base requirement for quality of service. Nonetheless, the documentation is a burden for the medical staff since it distracts from the clinical core process. An intuitive and user-friendly documentation system could increase documentation quality and reduce documentation workload. The optimal system solution would know what happened and the person documenting the step would need a single “confirm” button. In many cases, such a linear flow of activities is given as long as only one profession (e.g. anaestesiology, scrub nurse) is considered, but even in such cases, there might be derivations from the linear process flow and further interaction is required.
The metric and qualitative analysis of models of the upper and lower dental arches is an important aspect of orthodontic treatment planning. Currently available eLearning systems for dental education only allow access to digital learning materials, and do not interactively support the learning progress. Moreover, to date no study compared the efficiency of learning methods based on physical or digital study models. For this pilot study, 18 dental students were separated into two groups to investigate whether the learning success in study model analysis with an interactive elearning system is higher based on digital models or on conventional plaster models. The results show that with the digital method less time is needed per model analysis. Moreover, the digital approach leads to higher total scores than that based on plaster models. We conclude that interactive eLearning using digital dental arch models is a promising tool for dental education.
OR-Pad - Entwicklung eines Prototyps zur sterilen Informationsanzeige am OP-Situs : meeting abstract
(2019)
Hintergrund: Oftmals werden Informationen aus der Krankenakte oder von Bildgebungsverfahren nur auf recht weit vom Operationsgebiet entfernten Monitoren, außerhalb der ergonomischen Sichtachse des Operateurs, dargestellt. Dies führt dazu, dass relevante Informationen übersehen werden oder ihr Informationspotenzial nicht ausgeschöpft werden kann. In Papierform mitgenommene Notizen befinden sich während der OP außerhalb des sterilen Bereichs und sind dadurch für den Operateur nicht ohne Weiteres zugänglich. Auch bei intraoperativen Einträgen für die OP Dokumentation ist der Operateur auf die Mithilfe der Assistenz angewiesen. Durch die zusätzlichen Kommunikationswege entstehen dabei ein personeller und zeitlicher Mehraufwand und das Fehlerpotenzial nimmt zu. Das anwendungsorientierte Forschungsprojekt OR-Pad - Nutzung von portablen Informationsanzeigen im Operationssaal - soll dem Operateur zu einem verbesserten Informationsfluss verhelfen. Die Idee entstand aus der klinischen Routine der Anatomie und Urologie des Universitätsklinikums Tübingen und wird nun durch Fördermittel vom Ministerium für Wissenschaft, Forschung und Kunst Baden-Württemberg sowie vom Europäischen Fonds für regionale Entwicklung an der Hochschule Reutlingen zu einem High Fidelity-Prototypen weiterentwickelt.
Ziel: Ziel des OR-Pad Projekts ist es, während einer OP zum aktuellen Zeitpunkt klinisch relevante Informationen in unmittelbarer Nähe zum Operateur darzustellen. Mithilfe des Systems soll der Informationsfluss zwischen dem Eingriff sowie dessen Vor- und Nachbereitung optimiert werden. Der Operateur soll vorab relevante Informationen, wie aktuelle Röntgenbilder oder persönliche Notizen, zur intraoperativen Anzeige auswählen können, die dann am OP-Situs auf einer sterilen Informationsanzeige dargestellt werden. Durch die Positionierung soll eine ergonomische Sichtachse sowie die direkte Interaktion mit dem System ermöglicht werden. Kontextrelevante Informationen sollen basierend auf dem aktuellen OP-Verlauf durch die Entwicklung einer Situationserkennung automatisch bereitgestellt werden. Zur Optimierung des Informationsflusses gehört ebenfalls die Unterstützung der OP-Dokumentation. Für diese sollen während des Eingriffs manuell vom Operateur sowie automatisch vom System Einträge, wie Zeitpunkte oder intraoperative Aufnahmen, erstellt werden. Aus diesen soll nach dem Eingriff die OP-Dokumentation generiert und damit der Prozess qualitativer und zeiteffizienter gestaltet werden.
Methodik: Zur Erreichung des Ziels werden zunächst die klinischen Anforderungen spezifiziert und in ein Lastenheft überführt. Hierfür werden Interviews und Beobachtungen bei mehreren Interventionen durchgeführt. Nach dem User-Centered-Designprozess werden Personas und Nutzungsszenarien entworfen und mit klinischen Projektpartnern in mehreren Iterationen evaluiert. Es gilt eine Informationsarchitektur aufzubauen, die eine Einbettung klinischer Informationssysteme sowie Bild- und Gerätedaten aus dem OP-Netzwerk erlaubt. Eine Situationserkennung, basierend auf Prozessmodellen, soll zur Abschätzung des Operationsfortschritts entwickelt werden. Zur Befestigung der Informationsanzeige sollen geeignete Haltemechanismen eingesetzt werden. Das OR-Pad System soll laufend im Lehr- und Forschungs-OP der Hochschule Reutlingen getestet und im Sinne agiler Produktentwicklung mit den klinischen Projektpartnern abgestimmt werden. Der finale Funktionsprototyp soll abschließend in den Versuchs-OPs der Anatomie Tübingen getestet und evaluiert werden.
Ergebnisse: Über eine erste Datenerhebung mittels Contextual Inquiry konnten erste Anforderungen an das OR-Pad System erfasst werden, woraus ein Low-Fidelity-Prototyp resultierte. Die Evaluation über Experteninterviews führte in die zweite Iteration, in der das Konzept entsprechend der Ergebnisse angepasst wurde. Über Hospitationen am Uniklinikum Tübingen fand eine weitere Datenerhebung zur Erstellung von Szenarien für die intraoperativen Anwendungsfälle statt. Anhand der Anforderungen wurde ein Konzept für die Benutzerschnittstelle entworfen, die im weiteren Verlauf mit den klinischen Projektpartnern evaluiert wird.
The increasing heterogenecity of students at German Universities of Applied Sciences and the growing importance of digitization call for a rethinking of teaching and learning within higher education. In the next years, changing the learning ecosystem by developing and reflecting upon new teaching and learning techniques using methods of digitalization will be both - most relevant and very challenging. The following article introduces two different learning scenarios, which exemplify the implementation of new educational models that allow discontinuity of time and place, technology and process in teaching and learning. Within a blended learning apporach, the first learning scenario aims at adapting and individualizing the knowledge transfer in the course Foundations of Computer Science by providing knowledge individually and situation-specifically. The second learning scenario proposes a web-based tool to facilitate digital learning environments and thus digital learning communities and the possibility of computer-supported learning. The overall aim of both learning scenarios is to enhance learning for diverse groups by providing a different smart learning ecosystem in stepping away from a teacher-based to a student-centered approach. Both learning scenarios exemplarily represent the educational vision of Reutlingen University - its development into an interactive university.
Zur Unterstützung des Operateurs wird eine patientennahe Informationsanzeige entwickelt, die kontextrelevante Informationen entsprechend der aktuellen Situation bereitstellen kann. Hierfür soll eine Situationserkennung konzipiert werden, die auf unterschiedliche intraoperative Prozesse übertragen werden kann. Ziel der adaptiven Situationserkennung ist das Erkennen spezifischer Situationen durch intraoperative Informationen unterschiedlicher Datenquellen im Operationssaal. Innerhalb der Datenerhebung und -analyse wurden Anwendungsfälle für die Situationserkennung definiert sowie chirurgische Prozessmodelle erstellt, die intraoperative Ereignisse abbilden. Auf Basis dieser Informationen wurde ein Konzept entworfen, das sich zunächst auf die Erkennung abstrakter generalisierter Phasen, unabhängig vom Eingriff, fokussiert und sich Schritt für Schritt auf granulare Prozessschritte spezifizieren lässt. Diese Flexibilität soll die Übertragbarkeit des Konzepts auf intraoperative Prozesse ermöglichen und den Operateur dadurch gezielt mit kontextrelevanten Informationen unterstützen. Das Konzept wird in zukünftigen Schritten weiterentwickelt.
Workflow driven support systems in the peri-operative area have the potential to optimize clinical processes and to allow new situation-adaptive support systems. We started to develop a workflow management system supporting all involved actors in the operating theatre with the goal to synchronize the tasks of the different stakeholders by giving relevant information to the right team members. Using the OMG standards BPMN, CMMN and DMN gives us the opportunity to bring established methods from other industries into the medical field. The system shows each addressed actor their information in the right place at the right time to make sure every member can execute their task in time to ensure a smooth workflow. The system has the overall view of all tasks. Accordingly, a workflow management system including the Camunda BPM workflow engine to run the models, and a middleware to connect different systems to the workflow engine and some graphical user interfaces to show necessary information or to interact with the system are used. The complete pipeline is implemented with a RESTful web service. The system is designed to include different systems like hospital information system (HIS) via the RESTful web service very easily and without loss of data. The first prototype is implemented and will be expanded.
In der Orthopädie werden Robotersysteme bereits seit mehreren Jahren erfolgreich unterstützend eingesetzt. Dieser Ansatz erfordert die vorgelagerte Erstellung eines digitalen Modells auf Basis von medizinischen Bilddatensätzen. Die Erstellung und Überprüfung der Modelle soll in einer browserbasierten Client- Server-Anwendung erfolgen. Hierfür ist die Darstellung von zweidimensionalen und dreidimensionalen Datensätzen erforderlich. Basis dieses Papers ist die Entwicklung eines Ansatzes zur interaktiven, browserbasierten dreidimensionalen Darstellung medizinischer Planungsdaten. Die Anwendung stellt ein Proof of Concept dar, ob die bestehenden Desktopanwendungen zur Darstellung von Planungsdaten ersetzt werden können. Mit Hilfe des Frameworks AMI.js wurde die Anwendung umgesetzt. Sie erfüllt alle definierten Anforderungen und kann somit die aktuellen Desktopanwendungen ersetzen.
This study is about estimating the reproducibility of finding palpation points of three different anatomical landmarks in the human body (Xiphoid Process and the 2 Hip Crests) to support a navigated ultrasound application. On 6 test subjects with different body mass index the three palpation points were located five times by two examiners. The deviation from the target position was calculated and correlated to the fat thickness above each palpation point. The reproducibility of the measurements had a mean error of ≈13.5 mm +- 4 mm, which seems to be sufficient for the desired application field.