Stent graft visualization and planning tool for endovascular surgery using finite element analysis
(2014)
Purpose: A new approach to optimize stent graft selection for endovascular aortic repair is the use of finite element analysis. Once the finite element model is created and solved, a software module is needed to view the simulation results in the clinical work environment. A new tool for Interpretation of simulation results, named Medical Postprocessor, that enables comparison of different stent graft configurations and products was designed, implemented and tested. Methods Aortic endovascular stent graft ring forces and sealing states in the vessel landing zone of three different configurations were provided in a surgical planning software using the Medical Imaging Interaction Tool Kit (MITK) Software system. For data interpretation, software modules for 2D and 3D presentations were implemented. Ten surgeons evaluated the software features of the Medical Postprocessor. These surgeons performed usability tests and answered questionnaires based on their experience with the system.
Results: The Medical Postprocessor visualization system enabled vascular surgeons to determine the configuration with the highest overall fixation force in 16 ± 6 s, best proximal sealing in 56±24 s and highest proximal fixation force in 38 ± 12 s. The majority considered the multiformat data provided helpful and found the Medical Postprocessor to be an efficient decision support system for stent graft selection. The evaluation of the user interface results in an ISONORMconform user interface (113.5 points).
Conclusion: The Medical Postprocessor visualization Software tool for analyzing stent graft properties was evaluated by vascular surgeons. The results show that the software can assist the interpretation of simulation results to optimize stent graft configuration and sizing.
There are several intra-operative use cases which require the surgeon to interact with medical devices. We used the Leap Motion Controller as input device and implemented two use-cases: 2D-Interaction (e.g. advancing EPR data) and selection of a value (e.g. room illumination brightness). The gesture detection was successful and we mapped its output to several devices and systems.
Intra-operative fluoroscopy-guided assistance system for transcatheter aortic valve implantation
(2014)
A new surgical assistance system has been developed to assist the correct positioning of the AVP during transapical TAVI. The developed assistance system automatically defines the target area for implanting the AVP under live 2-D fluoroscopy guidance. Moreover, this surgical assistance system works with low levels of contrast agent for the final deployment of AVP, reducing therefore long-term negative effects, such as renal failure in the elderly and high-risk patients.
Model-guided Therapy and Surgical Workflow Systems are two interrelated research fields, which have been developed separately in the last years. To make full use of both technologies, it is necessary to integrate them and connect them to Hospital Information Systems. We propose a framework for integration of Model-guided Therapy in Hospital Information Systems based on the Electronic Medical Record, and a taskbased Workflow Management System, which is suitable for clinical end users. Two prototypes - one based on Business Process Modeling Language, one based on the serum-board - are presented. From the experience with these prototypes, we developed a novel personalized visualization system for Surgical Workflows and Model-guided Therapy. Key challenges for further development are automated situation detection and a common communication infrastructure.
Checklists are a valuable tool to ensure process quality and quality of care. To ensure proper integration in clinical processes, it would be desirable to generate checklists directly from formal process descriptions. Those checklists could also be used for user interaction in context-aware surgical assist systems. We built a tool to automatically convert Business Process Model and Notation (BPMN) process models to checklists displayed as HTML websites. Gateways representing decisions are mapped to checklist items that trigger dynamic content loading based on the placed checkmark. The usability of the resulting system was positively evaluated regarding comprehensibility and end-user friendliness.
Intraoperative brain deformation, so called brain shift, affects the applicability of preoperative magnetic resonance imaging (MRI) data to assist the procedures of intraoperative ultrasound (iUS) guidance during neurosurgery. This paper proposes a deep learning-based approach for fast and accurate deformable registration of preoperative MRI to iUS images to correct brain shift. Based on the architecture of 3D convolutional neural networks, the proposed deep MRI-iUS registration method has been successfully tested and evaluated on the retrospective evaluation of cerebral tumors (RESECT) dataset. This study showed that our proposed method outperforms other registration methods in previous studies with an average mean squared error (MSE) of 85. Moreover, this method can register three 3D MRI-US pair in less than a second, improving the expected outcomes of brain surgery.
In networked operating room environments, there is an emerging trend towards standardized non-proprietary communication protocols which allow to build new integration solutions and flexible human-machine interaction concepts. The most prominent endeavor is the IEEE 11073 SDC protocol. For some uses cases, it would be helpful if not just medical devices could be controlled based on SDC, but also building automation systems like light, shutters, air condition, etc. For those systems, the KNX protocol is widely used. We build an SDC-to-KNX gateway which allows to use the SDC protocol for sending commands to connected KNX devices. The first prototype system was successfully implemented at the demonstration operating room at Reutlingen University. This is a first step toward the integration of a broader variety of KNX devices.
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train The CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labelled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.
The focus of the developed maturity model was set on processes. The concept of the widespread CMM and its practices has been transferred to the perioperative domain and the concept of the new maturity model. Additional optimization goals and technological as well as networking-specific aspects enable a process- and object-focused view of the maturity model in order to ensure broad coverage of different subareas. The evaluation showed that the model is applicable to the perioperative field. Adjustments and extensions of the maturity model are future steps to improve the rating and classification of the new maturity model.
The metric and qualitative analysis of models of the upper and lower dental arches is an important aspect of orthodontic treatment planning. Currently available eLearning systems for dental education only allow access to digital learning materials, and do not interactively support the learning progress. Moreover, to date no study compared the efficiency of learning methods based on physical or digital study models. For this pilot study, 18 dental students were separated into two groups to investigate whether the learning success in study model analysis with an interactive elearning system is higher based on digital models or on conventional plaster models. The results show that with the digital method less time is needed per model analysis. Moreover, the digital approach leads to higher total scores than that based on plaster models. We conclude that interactive eLearning using digital dental arch models is a promising tool for dental education.