This study is about estimating the reproducibility of finding palpation points of three different anatomical landmarks in the human body (Xiphoid Process and the 2 Hip Crests) to support a navigated ultrasound application. On 6 test subjects with different body mass index the three palpation points were located five times by two examiners. The deviation from the target position was calculated and correlated to the fat thickness above each palpation point. The reproducibility of the measurements had a mean error of ≈13.5 mm +- 4 mm, which seems to be sufficient for the desired application field.
With the progress of technology in modern hospitals, an intelligent perioperative situation recognition will gain more relevance due to its potential to substantially improve surgical workflows by providing situation knowledge in real-time. Such knowledge can be extracted from image data by machine learning techniques but poses a privacy threat to the staff’s and patients’ personal data. De-identification is a possible solution for removing visual sensitive information. In this work, we developed a YOLO v3 based prototype to detect sensitive areas in the image in real-time. These are then deidentified using common image obfuscation techniques. Our approach shows that it is principle suitable for de-identifying sensitive data in OR images and contributes to a privacyrespectful way of processing in the context of situation recognition in the OR.
Model-guided Therapy and Surgical Workflow Systems are two interrelated research fields, which have been developed separately in the last years. To make full use of both technologies, it is necessary to integrate them and connect them to Hospital Information Systems. We propose a framework for integration of Model-guided Therapy in Hospital Information Systems based on the Electronic Medical Record, and a taskbased Workflow Management System, which is suitable for clinical end users. Two prototypes - one based on Business Process Modeling Language, one based on the serum-board - are presented. From the experience with these prototypes, we developed a novel personalized visualization system for Surgical Workflows and Model-guided Therapy. Key challenges for further development are automated situation detection and a common communication infrastructure.
Multi-dimensional patient data, such as time varying volume data, data of different imaging modalities, surface segmentations etc. are of growing importance in the clinical routine. For many use cases, it is of major importance to replicate a certain visualization of a data set created on one machine on a different computer using different software tools. Up until now, there exists no standardized methodology for this consistent presentation. We propose an extension of the Digital Imaging und Communications in Medicine (DICOM) called “Multi dimensional Presentation State” and outline scope and first results of the standardization process.
Motivation: Aim of this project is the automatic classification of total hip endoprosthesis (THEP) components in 2D Xray images. Revision surgeries of total hip arthroplasty (THA) are common procedures in orthopedics and trauma surgery. Currently, around 400.000 procedures per year are performed in the United States (US) alone. To achieve the best possible result, preoperative planning is crucial. Especially if parts of the current THEP system are to be retained.
Methods: First, a ground truth based on 76 X-ray images was created: We used an image processing pipeline consisting of a segmentation step performed by a convolutional neural network and a classification step performed by a support vector machine (SVM). In total, 11 classes (5 pans and 6 shafts) shall be classified.
Results: The ground truth generated was of good quality even though the initial segmentation was performed by technicians. The best segmentation results were achieved using a U-net architecture. For classification, SVM architectures performed much better than additional neural networks.
Conclusions: The overall image processing pipeline performed well, but the ground truth needs to be extended to include a broader variability of implant types and more examples per training class.
Clinical reading centers provide expertise for consistent, centralized analysis of medical data gathered in a distributed context. Accordingly, appropriate software solutions are required for the involved communication and data management processes. In this work, an analysis of general requirements and essential architectural and software design considerations for reading center information systems is provided. The identified patterns have been applied to the implementation of the reading center platform which is currently operated at the Center of Ophthalmology of the University Hospital of Tübingen.
An operating room is a stressful work environment. Nevertheless, all involved persons have to work safely as there is no space for mistakes. To ensure a high level of concentration and seamless interaction, all involved persons have to know their own tasks and the tasks of their colleagues. The entire team must work synchronously at all times. To optimize the overall workflow, a task manager supporting the team was developed. In parallel, a common conceptual design of a business process visualization was developed, which makes all relevant information accessible in real-time during a surgery. In this context an overview of all processes in the operating room was created and different concepts for the graphical representation of these user-dependent processes were developed. This paper describes the concept of the task manager as well as the general concept in the field of surgery.
Access to clinical information during interventions is an important aspect to support the surgeon and his team in the OR. The OR-Pad research project aims at displaying clinically relevant information close to the patient during surgery. With the OR-Pad system, the surgeon shall be able to access case-specific information, displayed on a sterile-packaged, portable display device. Therefore, information shall be prepared before surgery and also be available afterwards. The project follows an user-centered design process. Within the third iteration, the interaction concept was finalized, resulting in an application that can be used in two modes, mobile and intraoperative, to support the surgeon before/after and during surgery, respectively. By supporting the surgeon perioperatively, it is expected to improve the information situation in the OR and thereby the quality of surgical results. Based on this concept, the system architecture was designed in detail, using a client-server architecture. Components, communication interfaces, exchanged data, and intended standards for data exchange of the OR-Pad system including connecting systems were conceived. Expert interviews by using a clickable prototype were conducted to evaluate the concepts.
Purpose
Context awareness in the operating room (OR) is important to realize targeted assistance to support actors during surgery. A situation recognition system (SRS) is used to interpret intraoperative events and derive an intraoperative situation from these. To achieve a modular system architecture, it is desirable to de-couple the SRS from other system components. This leads to the need of an interface between such an SRS and context-aware systems (CAS). This work aims to provide an open standardized interface to enable loose coupling of the SRS with varying CAS to allow vendor-independent device orchestrations.
Methods
A requirements analysis investigated limiting factors that currently prevent the integration of CAS in today's ORs. These elicited requirements enabled the selection of a suitable base architecture. We examined how to specify this architecture with the constraints of an interoperability standard. The resulting middleware was integrated into a prototypic SRS and our system for intraoperative support, the OR-Pad, as exemplary CAS for evaluating whether our solution can enable context-aware assistance during simulated orthopedical interventions.
Results
The emerging Service-oriented Device Connectivity (SDC) standard series was selected to specify and implement a middleware for providing the interpreted contextual information while the SRS and CAS are loosely coupled. The results were verified within a proof of concept study using the OR-Pad demonstration scenario. The fulfillment of the CAS’ requirements to act context-aware, conformity to the SDC standard series, and the effort for integrating the middleware in individual systems were evaluated. The semantically unambiguous encoding of contextual information depends on the further standardization process of the SDC nomenclature. The discussion of the validity of these results proved the applicability and transferability of the middleware.
Conclusion
The specified and implemented SDC-based middleware shows the feasibility of loose coupling an SRS with unknown CAS to realize context-aware assistance in the OR.