Refine
Year of publication
Document Type
- Journal article (37)
- Book chapter (2)
Is part of the Bibliography
- yes (39)
Institute
- Life Sciences (37)
- Informatik (2)
Publisher
- De Gruyter (15)
- Macmillan Publishers Limited (3)
- ACS (2)
- CRC Press (2)
- Elsevier (2)
- MDPI (2)
- Nature Publishing Group (2)
- Royal Society of Chemistry (2)
- Wiley (2)
- de Gruyter (2)
- Beilstein-Institut zur Förderung der Chemischen Wissenschaften (1)
- Biomed Central (1)
- Hochschulen für Angewandte Wissenschaften Baden-Württemberg, Koordinierungsstelle (1)
- PLOS (1)
- Sage (1)
Tumorzellen on the move : mikrosystem-basierter Assay zur Untersuchung der Tumorzellen-Migration
(2016)
Die Invasion von Tumorzellen in umliegendes Gewebe und die Bildung von Metastasen transformieren einen lokal wachsenden Tumor in eine systemische und lebensbedrohliche Krankheit mit schlechter Prognose. Dabei spielt die aktive Migration der Tumorzellen eine entscheidende Rolle. Tumorzellen gelangen durch die aktive Zellbewegung in das Lymph- oder Blutsystem und breiten sich im Körper aus. Bei der Invasion in ein neues Organ migrieren die Zellen ebenfalls wieder in komplexer Weise durch das Gewebe und können schließlich dort Metastasen bilden. Auf Grund der enormen medizinischen Relevanz der Tumorzell-Invasion, wird die Bewegung von Tumorzellen seit Jahrzehnten unter Laborbedingungen umfassend untersucht und ist ein wichtiger Marker für die Aggressivität der Tumorzellen. Zur Bewegungsanalyse gibt es mehrere experimentelle und auch kommerziell erhältliche in-vitro Untersuchungsmethoden. Ziel des interdisziplinären Projektes „MigChip“ ist die Entwicklung, Herstellung und experimentelle Validierung eines Mikrofludik-Chips zur verbesserten, detailgenauen in-vitro Untersuchung der Tumorzellen-Migration.
Adapting characteristics of biomaterials specifically for in vitro and in vivo applications is becoming increasingly important in order to control interactions between material and biological systems. These complex interactions are influenced by surface properties like chemical composition, charge, mechanical and topographic attributes. In many cases it is not useful or even not possible to alter the base material but changing surface, to improve biocompatibility or to make surfaces bioactive, may be achieved by thin coatings. An already established method is the coating with polyelectrolyte multilayers (PEM). To adjust adhesion, proliferation and improve vitality of certain cell types, we modified the roughness of PEM coatings. We included different types nanoparticles (NP’s) in different concentrations into PEM coatings for controlling surface roughness. Surface properties were characterized and the reaction of 3 different cell types on these coatings was tested.
Knee osteoarthritis is a common complication and can lead to total loss of joint function in patients. Treatment by either partial or total knee replacement with appropriate UHMWPE based implantsis highly invasive, may cause complications and may show unsatisfying results. Alternatively, treatment may be done by insertion of an elastic interpositional knee spacer with optimized material characteristics.
We report the development of high performance polyurethane-based polymers modified with bioactive molecules for fabrication of such knee spacers. In order to tailor mechanical and tribological properties and to improve resist to enzymatic degradation we propose a core-shell model for the spacer with specifically adapted properties.
Characterisation of porous knitted titanium for replacement of intervertebral disc nucleus pulposus
(2017)
Effective restoration of human intervertebral disc degeneration is challenged by numerous limitations of the currently available spinal fusion and arthroplasty treatment strategies. Consequently, use of artificial biomaterial implant is gaining attention as a potential therapeutic strategy. Our study is aimed at investigating and characterizing a novel knitted titanium (Ti6Al4V) implant for the replacement of nucleus pulposus to treat early stages of chronic intervertebral disc degeneration. Specific knitted geometry of the scaffold with a porosity of 67.67 ± 0.824% was used to overcome tissue integration failures. Furthermore, to improve the wear resistance without impairing original mechanical strength, electro-polishing step was employed. Electro-polishing treatment changed a surface roughness from 15.22 ± 3.28 to 4.35 ± 0.87 μm without affecting its wettability which remained at 81.03 ± 8.5°. Subsequently, cellular responses of human mesenchymal stem cells (SCP1 cell line) and human primary chondrocytes were investigated which showed positive responses in terms of adherence and viability. Surface wettability was further enhanced to super hydrophilic nature by oxygen plasma treatment, which eventually caused substantial increase in the proliferation of SCP1 cells and primary chondrocytes. Our study implies that owing to scaffolds physicochemical and biocompatible properties, it could improve the clinical performance of nucleus pulposus replacement.
Cell-cell and cell-extracellular matrix (ECM) adhesion regulates fundamental cellular functions and is crucial for cell-material contact. Adhesion is influenced by many factors like affinity and specificity of the receptor-ligand interaction or overall ligand concentration and density. To investigate molecular details of cell ECM and cadherins (cell-cell) interaction in vascular cells functional nanostructured surfaces were used Ligand-functionalized gold nanoparticles (AuNPs) with 6-8 nm diameter, are precisely immobilized on a surface and separated by non-adhesive regions so that individual integrins or cadherins can specifically interact with the ligands on the AuNPs. Using 40 nm and 90 nm distances between the AuNPs and functionalized either with peptide motifs of the extracellular matrix (RGD or REDV) or vascular endothelial cadherins (VEC), the influence of distance and ligand specificity on spreading and adhesion of endothelial cells (ECs) and smooth muscle cells (SMCs) was investigated. We demonstrate that RGD-dependent adhesion of vascular cells is similar to other cell types and that the distance dependence for integrin binding to ECM-peptides is also valid for the REDV motif. VEC-ligands decrease adhesion significantly on the tested ligand distances. These results may be helpful for future improvements in vascular tissue engineering and for development of implant surfaces.
Intermediate filament reorganization dynamically influences cancer cell alignment and migration
(2017)
The interactions between a cancer cell and its extracellular matrix (ECM) have been the focus of an increasing amount of investigation. The role of the intermediate filament keratin in cancer has also been coming into focus of late, but more research is needed to understand how this piece fits in the puzzle of cytoskeleton-mediated invasion and metastasis. In Panc-1 invasive pancreatic cancer cells, keratin phosphorylation in conjunction with actin inhibition was found to be sufficient to reduce cell area below either treatment alone. We then analyzed intersecting keratin and actin fibers in the cytoskeleton of cyclically stretched cells and found no directional correlation. The role of keratin organization in Panc-1 cellular morphological adaptation and directed migration was then analyzed by culturing cells on cyclically stretched polydimethylsiloxane (PDMS) substrates, nanoscale grates, and rigid pillars. In general, the reorganization of the keratin cytoskeleton allows the cell to become more ‘mobile’- exhibiting faster and more directed migration and orientation in response to external stimuli. By combining keratin network perturbation with a variety of physical ECM signals, we demonstrate the interconnected nature of the architecture inside the cell and the scaffolding outside of it, and highlight the key elements facilitating cancer cell-ECM interactions.
A wide variety of cell types exhibit substrate topography-based behavior, also known as contact guidance. However, the precise cellular mechanisms underlying this process are still unknown. In this study, we investigated contact guidance by studying the reaction of human endothelial cells (ECs) to well-defined microgroove topographies, both during and after initial cell spreading. As the cytoskeleton plays a major role in cellular adaptation to topographical features, two methods were used to perturb cytoskeletal structures. Inhibition of actomyosin contractility with the chemical inhibitor blebbistatatin demonstrated that initial contact guidance events are independent of traction force generation. However, cell alignment to the grooved substrate was altered at later time points, suggesting an initial ‘passive’ phase of contact guidance, followed by a contractility-dependent ‘active’ phase that relies on mechanosensitive feedback. The actin cytoskeleton was also perturbed in an indirect manner by culturing cells upside down, resulting in decreased levels of contact guidance and suggesting that a possible loss of contact between the actin cytoskeleton and the substrate could lead to cytoskeleton impairment. The process of contact guidance at the microscale was found to be primarily lamellipodia driven, as no bias in filopodia extension was observed on micron-scale grooves.
We present an approach for segmenting individual cells and lamellipodia in epithelial cell clusters using fully convolutional neural networks. The method will set the basis for measuring cell cluster dynamics and expansion to improve the investigation of collective cell migration phenomena. The fully learning-based front-end avoids classical feature engineering, yet the network architecture needs to be designed carefully. Our network predicts how likely each pixel belongs to one of the classes and, thus, is able to segment the image. Besides characterizing segmentation performance, we discuss how the network will be further employed.
Perivascular stromal cells, including mesenchymal stem/stromal cells (MSCs), secrete paracrine factor in response to exercise training that can facilitate improvements in muscle remodeling. This study was designed to test the capacity for muscle-resident MSCs (mMSCs) isolated from young mice to release regenerative proteins in response to mechanical strain in vitro, and subsequently determine the extent to which strain-stimulated mMSCs can enhance skeletal muscle and cognitive performance in a mouse model of uncomplicated aging. Protein arrays confirmed a robust increase in protein release at 24 h following an acute bout of mechanical strain in vitro (10%, 1 Hz, 5 h) compared to non-strain controls. Aged (24 month old), C57BL/6 mice were provided bilateral intramuscular injection of saline, non strain control mMSCs, or mMSCs subjected to a single bout of mechanical strain in vitro (4 ×104). No significant changes were observed in muscle weight, myofiber size, maximal force, or satellite cell quantity at 1 or 4 wks between groups. Peripheral perfusion was significantly increased in muscle at 4 wks post-mMSC injection (p < 0.05), yet no difference was noted between control and preconditioned mMSCs. Intramuscular injection of preconditioned mMSCs increased the number of new neurons and astrocytes in the dentate gyrus of the hippocampus compared to both control groups (p < 0.05), with a trend toward an increase in water maze performance noted (p=0.07). Results from this study demonstrate that acute injection of exogenously stimulated muscle-resident stromal cells do not robustly impact aged muscle structure and function, yet increase the survival of new neurons in the hippocampus.
A series of novel biomedical TPCUs with different percentages of hard segment and a silicone component in the soft segment were synthesized in a multi stage one-pot method. The kinetic profiles of the urethane formation in TPCU-based copolymer systems were monitored by rheological, in line FTIR spectroscopic (React IR) and real-time calorimetric (RC1) methods. This process-analytically monitored multi step synthesis was successfully used to optimize the production of medical-grade TPCU elastomers on preparative scale (in lots of several kg) with controlled molecular structure and mechanical properties. Various surface and bulk analytical methods as well as systematic studies of the mechanic response of the elastomer end-products towards compression and tensile loading were used to estimate the bio-stability of the prepared TPCUs in vitro after 3 months. The tests suggested that high bio-stability of all polyurethane formulations using accelerating in vitro test can be attributed to the synthetic design as well as to the specific techniques used for specimen preparation, namely: (1) the annealing for reducing residual polymer surface stress and preventing IES, (2) stabilization of the morphology by long time storage of the specimens after processing before being immersed in the test liquids, (3) purification by extraction to remove the shot chain oligomers which are the most susceptible to degradation. All mechanical tests were performed on cylindrical and circular disc specimens for modelling the thickness of the meniscus implants under application-relevant stress conditions.