Refine
Year of publication
Document Type
- Journal article (36) (remove)
Language
- English (36) (remove)
Is part of the Bibliography
- yes (36)
Institute
- Life Sciences (34)
- Informatik (2)
Publisher
- De Gruyter (15)
- Macmillan Publishers Limited (3)
- ACS (2)
- Elsevier (2)
- MDPI (2)
- Nature Publishing Group (2)
- Royal Society of Chemistry (2)
- Wiley (2)
- de Gruyter (2)
- Beilstein-Institut zur Förderung der Chemischen Wissenschaften (1)
A series of novel biomedical TPCUs with different percentages of hard segment and a silicone component in the soft segment were synthesized in a multi stage one-pot method. The kinetic profiles of the urethane formation in TPCU-based copolymer systems were monitored by rheological, in line FTIR spectroscopic (React IR) and real-time calorimetric (RC1) methods. This process-analytically monitored multi step synthesis was successfully used to optimize the production of medical-grade TPCU elastomers on preparative scale (in lots of several kg) with controlled molecular structure and mechanical properties. Various surface and bulk analytical methods as well as systematic studies of the mechanic response of the elastomer end-products towards compression and tensile loading were used to estimate the bio-stability of the prepared TPCUs in vitro after 3 months. The tests suggested that high bio-stability of all polyurethane formulations using accelerating in vitro test can be attributed to the synthetic design as well as to the specific techniques used for specimen preparation, namely: (1) the annealing for reducing residual polymer surface stress and preventing IES, (2) stabilization of the morphology by long time storage of the specimens after processing before being immersed in the test liquids, (3) purification by extraction to remove the shot chain oligomers which are the most susceptible to degradation. All mechanical tests were performed on cylindrical and circular disc specimens for modelling the thickness of the meniscus implants under application-relevant stress conditions.
Age-dependent migratory behavior of human endothelial cells revealed by substrate microtopography
(2019)
Cell migration is part of many important in vivo biological processes and is influenced by chemical and physical factors such as substrate topography. Although the migratory behavior of different cell types on structured substrates has already been investigated, up to date it is largely unknown if specimen's age affects cell migration on structures. In this work, we investigated age-dependent migratory behavior of human endothelial cells from young (≤ 31 years old) and old (≥ 60 years old) donors on poly(dimethylsiloxane) microstructured substrates consisting of well-defined parallel grooves. We observed a decrease in cell migration velocity in all substrate conditions and in persistence length perpendicular to the grooves in cells from old donors. Nevertheless, in comparison to young cells, old cells exhibited a higher cell directionality along grooves of certain depths and a higher persistence time. We also found a systematic decrease of donor age dependent responses of cell protrusions in orientation, velocity and length, all of them decreased in old cells. These observations lead us to hypothesize a possible impairment of actin cytoskeleton network and affected actin polymerization and steering systems, caused by aging.
In Neurofibromatosis 1 (NF1) germ line loss of function mutations result in reduction of cellular neurofibromin content (NF1+/−, NF1 haploinsufficiency). The Ras-GAP neurofibromin is a very large cytoplasmic protein (2818 AA, 319 kDa) involved in the RAS-MAPK pathway. Aside from regulation of proliferation, it is involved in mechanosensoric of cells. We investigated neurofibromin replacement in cultured human fibroblasts showing reduced amount of neurofibromin. Full length neurofibromin was produced recombinantly in insect cells and purified. Protein transduction into cultured fibroblasts was performed employing cell penetrating peptides along with photochemical internalization. This combination of transduction strategies ensures the intracellular uptake and the translocation to the cytoplasm of neurofibromin. The transduced neurofibromin is functional, indicated by functional rescue of reduced mechanosensoric blindness and reduced RasGAP activity in cultured fibroblasts of NF1 patients or normal fibroblasts treated by NF1 siRNA. Our study shows that recombinant neurofibromin is able to revert cellular effects of NF1 haploinsuffiency in vitro, indicating a use of protein transduction into cells as a potential treatment strategy for the monogenic disease NF1.
Surface topographies are often discussed as an important parameter influencing basic cell behavior. Whereas most in vitro studies deal with microstructures with sharp edges, smooth, curved microscale topographies might be more relevant concerning in-vivo situations. Addressing the lack of highly defined surfaces with varying curvature, we present a topography chip system with 3D curved features of varying spacing, curvature radii as well as varying overall dimensions of curved surfaces. The CurvChip is produced by low-cost photolithography with thermal reflow, subsequent (repetitive) PDMS molding and hot embossing. The platform facilitates the systematic in-vitro investigation of the impact of substrate curvature on cell types like epithelial, endothelial, smooth muscle cells, or stem cells. Such investigations will not only help to further understand the mechanism of curvature sensation but may also contribute to optimize cell-material interactions in the field of regenerative medicine.
Analysis of multicellular patterns is required to understand tissue organizational processes. By using a multi-scale object oriented image processing method, the spatial information of cells can be extracted automatically. Instead of manual segmentation or indirect measurements, such as general distribution of contrast or flow, the orientation and distribution of individual cells is extracted for quantitative analysis. Relevant objects are identified by feature queries and no low-level knowledge of image processing is required.
Soft lithography, a tool widely applied in biology and life sciences with numerous applications, uses the soft molding of photolithography-generated master structures by polymers. The central part of a photolithography set-up is a mask-aligner mostly based on a high-pressure mercury lamp as an ultraviolet (UV) light source. This type of light source requires a high level of maintenance and shows a decreasing intensity over its lifetime, influencing the lithography outcome. In this paper, we present a low-cost, bench-top photolithography tool based on ninety-eight 375 nm light-emitting diodes (LEDs). With approx. 10 W, our presented lithography set-up requires only a fraction of the energy of a conventional lamp, the LEDs have a guaranteed lifetime of 1000 h, which becomes noticeable by at least 2.5 to 15 times more exposure cycles compared to a standard light source and with costs less than 850 C it is very affordable. Such a set-up is not only attractive to small academic and industrial fabrication facilities who want to enable work with the technology of photolithography and cannot afford a conventional set-up, but also microfluidic teaching laboratories and microfluidic research and development laboratories, in general, could benefit from this cost-effective alternative. With our self-built photolithography system, we were able to produce structures from 6 μm to 50 μm in height and 10 μm to 200 μm in width. As an optional feature, we present a scaled-down laminar flow hood to enable a dust-free working environment for the photolithography process.
Focal adhesion clusters (FAC) are dynamic and complex structures that help cells to sense physicochemical properties of their environment. Research in biomaterials, cell adhesion or cell migration often involves the visualization of FAC by fluorescence staining and microscopy, which necessitates quantitative analysis of FAC and other cell features in microscopy images using image processing. Fluorescence microscopy images of human umbilical vein endothelial cells (HUVEC) obtained at 63x magnification were quantitatively analysed using ImageJ software. A generalised algorithm for selective segmentation and morphological analysis of FAC, nucleus and cell morphology is implemented. Further, a method for discrimination of FACnear the nucleus and around the periphery is implemented using masks. Our algorithm is able to effectively quantify different morphological characteristics of cell components and shows a high sensitivity and specificity while providing a modular software implementation.
Cell migration plays an essential role in wound healing and inflammatory processes inside the human body. Peripheral blood neutrophils, a type of polymorphonuclear leukocyte (PMN), are the first cells to be activated during inflammation and subsequently migrate toward an injured tissue or infection site. This response is dependent on both biochemical signaling and the extracellular environment, one aspect of which includes increased temperature in the tissues surrounding the inflammation site. In our study, we analyzed temperature-dependent neutrophil migration using differentiated HL-60 cells. The migration speed of differentiated HL-60 cells was found to correlate positively with temperature from 30 to 42 °C, with higher temperatures inducing a concomitant increase in cell detachment. The migration persistence time of differentiated HL-60 cells was higher at lower temperatures (30–33 °C), while the migration persistence length stayed constant throughout the temperature range. Coupled with the increased speed observed at high temperatures, this suggests that neutrophils are primed to migrate more effectively at the elevated temperatures characteristic of inflammation. Temperature gradients exist on both cell and tissue scales. Taking this into consideration, we also investigated the ability of differentiated HL-60 cells to sense and react to the presence of temperature gradients, a process known as thermotaxis. Using a two-dimensional temperature gradient chamber with a range of 27–43 °C, we observed a migration bias parallel to the gradient, resulting in both positive and negative thermotaxis. To better mimic the extracellular matrix (ECM) environment in vivo, a three-dimensional collagen temperature gradient chamber was constructed, allowing observation of biased neutrophil-like differentiated HL-60 migration toward the heat source.
Programmable nano-bio interfaces driven by tuneable vertically configured nanostructures have recently emerged as a powerful tool for cellular manipulations and interrogations. Such interfaces have strong potential for ground-breaking advances, particularly in cellular nanobiotechnology and mechanobiology. However, the opaque nature of many nanostructured surfaces makes non-destructive, live-cell characterization of cellular behavior on vertically aligned nanostructures challenging to observe. Here, a new nanofabrication route is proposed that enables harvesting of vertically aligned silicon (Si) nanowires and their subsequent transfer onto an optically transparent substrate, with high efficiency and without artefacts. We demonstrate the potential of this route for efficient live-cell phase contrast imaging and subsequent characterization of cells growing on vertically aligned Si nanowires. This approach provides the first opportunity to understand dynamic cellular responses to a cell-nanowire interface, and thus has the potential to inform the design of future nanoscale cellular manipulation technologies.
Increasing number of studies are focused on how adherent cells respond, in vitro, to different properties of a material. Typical properties are the surface chemistry, topographical cues (at the nano- and micro-scale) of the surface, and the substrate stiffness. Cell Response studies are of importance for designing new biomaterials with applications in cell culture technologies, regenerative medicine, or for medical implants. However, only very few studies take the cell age factor, respectively the donor age, into account. In this work, we tested two types of human vascular cells (smooth muscle and endothelial cells) from old and young donors on (a) micro-structured surfaces made of pol (dimethylsiloxane) or on (b) flat polyacrylamide hydrogels with varying stiffnesses. These experiments reveal age-dependent and cell typedependent differences in the cell response to the topography and stiffness, and may establish the Basis for further studies focusing on cell age-dependent responses.