Positively charged metallic oxides prevent blood coagulation whereas negatively charged metallic oxides are thrombogenic. This study was performed to examine whether this effect extends to metallic oxide nanoparticles. Oscillation shear rheometry was used to study the effect of zinc oxide and silicon dioxide nanoparticles on thrombus formation in human whole blood. Our data show that oscillation shear rheometry is a sensitive and robust technique to analyze thrombogenicity induced by nanoparticles. Blood without previous contact with nanoparticles had a clotting time (CT) of 16.7 ± 1.0 min reaching a maximal clot strength (CS) of 16 ± 14 Pa (G') after 30 min. ZnO nanoparticles (diameter 70 nm, +37 mV zeta-potential) at a concentration of 1 mg/mL prolonged CT to 20.8 ± 3.6 min and provoked a weak clot (CS 1.5 ± 1.0 Pa). However, at a lower concentration of 100 µg/mL the ZnO particles dramatically reduced CT to 6.0 ± 0.5 min and increased CS to 171 ± 63 Pa. This procoagulant effect decreased at lower concentrations reaching the detection limit at 10 ng/mL. SiO2 nanoparticles (diameter 232 nm, −28 mV zeta-potential) at high concentrations (1 mg/mL) reduced CT (2.1 ± 0.2 min) and stimulated CS (249 ± 59 Pa). Similar to ZnO particles, this procoagulant effect reached a detection limit at 10 ng/mL. Nanoparticles in high concentrations reproduce the surface charge effects on blood coagulation previously observed with large particles or solid metal oxides. However, nanoparticles with different surface charges equally well stimulate coagulation at lower concentrations. This stimulation may be an effect which is not directly related to the surface charge.
The interaction between lipid bilayers in water has been intensively studied over the last decades. Osmotic stress was applied to evaluate the forces between two approaching lipid bilayers in aqueous solution. The force–distance relation between lipid mono- or bilayers deposited on mica sheets using a surface force apparatus (SFA) was also measured. Lipid stabilised foam films offer another possibility to study the interactions between lipid monolayers. These films can be prepared comparatively easy with very good reproducibility. Foam films consist usually of two adsorbed surfactant monolayers separated by a layer of the aqueous solution from which the film is created. Their thickness can be conveniently measured using microinterferometric techniques. Studies with foam films deliver valuable information on the interactions between lipid membranes and especially their stability and permeability. Presenting inverse black lipid membrane (BLM) foam films supply information about the properties of the lipid self-organisation in bilayers. The present paper summarises results on microscopic lipid stabilised foam films by measuring their thickness and contact angle. Most of the presented results concern foam films prepared from dispersions of the zwitterionic lipid 1,2-dimyristoyl-sn-glycero-3-phosphorylcholine (DMPC) and some of its mixtures with the anionic lipid — 1,2-dimyristoyl-sn-glycero-3-[phospho-rac-(1-glycerol)] (DMPG).
The strength of the long range and short range forces between the lipid layers is discussed. The van der Waals attractive force is calculated. The electrostatic repulsive force is estimated from experiments at different electrolyte concentrations (NaCl, CaCl2) or by modification of the electrostatic double layer surface potential by incorporating charged lipids in the lipid monolayers. The short range interactions are studied and modified by using small carbohydrates (fructose and sucrose), ethanol (EtOH) or dimethylsulfoxide (DMSO). Some results are compared with the structure of lipid monolayers deposited at the liquid/air interface (monolayers spread in Langmuir trough), which are one of most studied biomembrane model system. The comparison between the film thickness and the free energy of film formation is used to estimate the contribution of the different components of the disjoining pressure to the total interaction in the film and their dependence on the composition of the film forming solution.
Medical implants play a central role in modern medicine and both, naturally derived and synthetic materials have been explored as biomaterials for such devices. However, when implanted into living tissue, most materials initiate a host response. In addition, implants often cause bacterial infections leading to complications. Polyelectrolyte multilayer (PEM) coatings can be used for functionalization of medical implants improving the implant integration and reducing foreign body reactions. Some PEMs are also known to show antibacterial properties. We developed a PEM coating suggesting that it can decrease the risk of bacterial infections occurring after implantation while being highly biocompatible. We applied two different standard tests for evaluating the PEM’s antibacterial properties, the ISO norm (ISO 22196) and one ASTM norm (ASTM E2180) test. We found a reduction of bacterial growth on the PEM but to a different degree depending on the testing method. This result demonstrates the need for defining proper method to evaluate antibacterial properties of surface coatings.
Controlling the surface properties and structure of thin nanosized coatings is of primary importance in diverse engineering and medical applications. Here we report on how the nanostructure, growth mechanism, thickness, roughness, and hydrophilicity of nanocomposites composed of weak natural or strong synthetic polyelectrolytes (PE) can be tailored by graphene oxide (GO) doping. GO reverses the build‐up mechanism affecting the internal structure and the hydrophilicity in a way depending on the type of the PE‐matrix. The extent of GO‐adsorption and its impact on the surface morphology was found to be independent on the type of the underlying PE‐matrix. The nanostructure of the hybrid films is not significantly altered when a single surface‐exposed GO‐layer is deposited, while increasing the number of embedded GO‐layers leads to pronounced surface heterogeneity. These results are expected to have valuable impact on the construction strategies of coatings with tunable surface properties.
Introduction: Bioresorbable collagenous barrier membranes are used to prevent premature soft tissue ingrowth and to allow bone regeneration. For volume stable indications, only non-absorbable synthetic materials are available. This study investigates a new bioresorbable hydrofluoric acid (HF)-treated magnesium (Mg) mesh in a native collagen membrane for volume stable situations. Materials and Methods: HF-treated and untreated Mg were compared in direct and indirect cytocompatibility assays. In vivo, 18 New Zealand White Rabbits received each four 8 mm calvarial defects and were divided into four groups: (a) HF-treated Mg mesh/collagen membrane, (b) untreated Mg mesh/collagen membrane (c) collagen membrane and (d) sham operation. After 6, 12 and 18 weeks, Mg degradation and bone regeneration was measured using radiological and histological methods. Results: In vitro, HF-treated Mg showed higher cytocompatibility. Histopathologically, HF-Mg prevented gas cavities and was degraded by mononuclear cells via phagocytosis up to 12 weeks. Untreated Mg showed partially significant more gas cavities and a fibrous tissue reaction. Bone regeneration was not significantly different between all groups. Discussion and Conclusions: HF-Mg meshes embedded in native collagen membranes represent a volume stable and biocompatible alternative to the non-absorbable synthetic materials. HF-Mg shows less corrosion and is degraded by phagocytosis. However, the application of membranes did not result in higher bone regeneration.
The present publication reports the purification effort of two natural bone blocks, that is, an allogeneic bone block (maxgraft®, botiss biomaterials GmbH, Zossen, Germany) and a xenogeneic block (SMARTBONE®, IBI S.A., Mezzovico Vira, Switzerland) in addition to previously published results based on histology. Furthermore, specialized scanning electron microscopy (SEM) and in vitro analyses (XTT, BrdU, LDH) for testing of the cytocompatibility based on ISO 10993-5/-12 have been conducted. The microscopic analyses showed that both bone blocks possess a trabecular structure with a lamellar subarrangement. In the case of the xenogeneic bone block, only minor remnants of collagenous structures were found, while in contrast high amounts of collagen were found associated with the allogeneic bone matrix. Furthermore, only island-like remnants of the polymer coating in case of the xenogeneic bone substitute seemed to be detectable. Finally, no remaining cells or cellular remnants were found in both bone blocks. The in vitro analyses showed that both bone blocks are biocompatible. Altogether, the purification level of both bone blocks seems to be favorable for bone tissue regeneration without the risk for inflammatory responses or graft rejection. Moreover, the analysis of the maxgraft® bone block showed that the underlying purification process allows for preserving not only the calcified bone matrix but also high amounts of the intertrabecular collagen matrix.
The aim of this study was to predefine the pore structure of β-tricalcium phosphate (β-TCP) scaffolds with different macro pore sizes (500, 750, and 1000 µm), to characterize β-TCP scaffolds, and to investigate the growth behavior of cells within these scaffolds. The lead structures for directional bone growth (sacrificial structures) were produced from polylactide (PLA) using the fused deposition modeling techniques. The molds were then filled with β-TCP slurry and sintered at 1250° C, whereby the lead structures (voids) were burnt out. The scaffolds were mechanically characterized (native and after incubation in simulated body fluid (SBF) for 28 d). In addition, biocompatibility was investigated by live/dead, cell proliferation and lactate dehydrogenase assays.
Polyelectrolyte multilayer coatings (PEM) are prepared by alternative layer-by-layer deposition of cationic and anionic polyelectrolyte monolayers on charged surfaces. The thickness of the coatings ranges from nm to few μm. Their properties such as roughness, stiffness, surface charge and surface energy can be precisely tuned to fulfil different technical or biological requirements. The coating process is based on self-assembly of polyelectrolytes. Advantages of these coatings are their easy handling, no harsh chemistry and the possibility for coatings on complex geometries. The PEM coatings can be prepared from a variety of suitable polyelectrolytes. Their stability varies from very durable PEM coatings that are only soluble in strong solvents to quickly degradable, which may be applied as drug release system. One example of such a degradable PEM system is the one based on the polyelectrolyte pair Hyaluronan (HA) and Chitosan (CHI). These biopolymers originate from natural sources and show low toxicity towards human cells. However, HA/CHI multilayers show only weak adhesiveness for human umbilical vein endothelial cells (HUVEC). In this article, we summarize our approaches to enhance the HA/CHI multilayer by incorporation of a non-polymer substance –graphene oxide– to improve the cell adhesion and keep such properties as low cytotoxicity and biodegradability. Different approaches for incorporation of graphene oxide were performed and the cellular adhesion was tested by metabolic assay.
High moisture permeability, excellent mechanical properties in a wet state, high water-holding capability, and high exudate absorption make bacterial nanocellulose (BNC) a favorable candidate for biomedical device production, especially wound dressings. The lack of antibacterial activity and healing-promoting ability are the main drawbacks that limit its wide application. Pullulan (Pul) is a nontoxic polymer that can promote wound healing. Zinc oxide nanoparticles (ZnO-NPs) are well-known as a safe antibacterial agent. In this study, aminoalkylsilane was chemically grafted on a BNC membrane (A-g-BNC) and used as a bridge to combine BNC with Pul-ZnO-NPs hybrid electrospun nanofibers. FTIR results confirmed the successful production of A-g-BNC/Pul-ZnO. The obtained dressing demonstrated blood clotting performance better than that of BNC. The dressing showed an ability to release ZnO, and its antibacterial activity was up to 5 log values higher than that of BNC. The cytotoxicity of the dressing toward L929 fibroblast cells clearly showed safety due to the proliferation of fibroblast cells. The animal test in a rat model indicated faster healing and re-epithelialization, small blood vessel formation, and collagen synthesis in the wounds covered by A-g-BNC/Pul-ZnO. The new functional dressing, fabricated with a cost-effective and easy method, not only showed excellent antibacterial activity but could also accelerate wound healing.
Controlled adhesion of HUVEC on polyelectrolyte multilayers by regulation of coating conditions
(2021)
Adhesion of host cells on the surface of implants is necessary for a healthy ingrowth of the implanted material. One possibility of surface modification is the coating of the implant with a second material with advantageous physical–chemical surface properties for the biological system. The coverage with blood proteins takes place immediately after implantation. It is followed by host–cell interaction on the surface. In this work, the effect of polyelectrolyte multilayer coatings (PEMs) on adhesion and activity of human umbilical vein endothelial cells (HUVECs) was studied. The PEMs were formed from poly(styrenesulfonate) (PSS) and poly(allylamine hydrochloride) (PAH) from solutions with different concentrations of NaCl varying between 0 and 1.0 M. The adhesion of HUVEC and their viability on the PEM is related to the amount of adsorbed proteins from the applied cell growth medium. The amount of adsorbed proteins is controlled not only by the surface charge but also by the internal excess charge of the PEM. The internal excess charge of the PEM was controlled by changing the electrolyte concentration in the deposition solutions.