Refine
Year of publication
Document Type
- Journal article (30)
Language
- English (30)
Has full text
- yes (30) (remove)
Is part of the Bibliography
- yes (30)
Institute
- Life Sciences (30)
Publisher
- MDPI (7)
- Wiley (5)
- De Gruyter (4)
- ACS (3)
- American Chemical Society (3)
- Elsevier (3)
- IIAR (2)
- BAN (1)
- Frontiers Media (1)
- de Gruyter (1)
Positively charged metallic oxides prevent blood coagulation whereas negatively charged metallic oxides are thrombogenic. This study was performed to examine whether this effect extends to metallic oxide nanoparticles. Oscillation shear rheometry was used to study the effect of zinc oxide and silicon dioxide nanoparticles on thrombus formation in human whole blood. Our data show that oscillation shear rheometry is a sensitive and robust technique to analyze thrombogenicity induced by nanoparticles. Blood without previous contact with nanoparticles had a clotting time (CT) of 16.7 ± 1.0 min reaching a maximal clot strength (CS) of 16 ± 14 Pa (G') after 30 min. ZnO nanoparticles (diameter 70 nm, +37 mV zeta-potential) at a concentration of 1 mg/mL prolonged CT to 20.8 ± 3.6 min and provoked a weak clot (CS 1.5 ± 1.0 Pa). However, at a lower concentration of 100 µg/mL the ZnO particles dramatically reduced CT to 6.0 ± 0.5 min and increased CS to 171 ± 63 Pa. This procoagulant effect decreased at lower concentrations reaching the detection limit at 10 ng/mL. SiO2 nanoparticles (diameter 232 nm, −28 mV zeta-potential) at high concentrations (1 mg/mL) reduced CT (2.1 ± 0.2 min) and stimulated CS (249 ± 59 Pa). Similar to ZnO particles, this procoagulant effect reached a detection limit at 10 ng/mL. Nanoparticles in high concentrations reproduce the surface charge effects on blood coagulation previously observed with large particles or solid metal oxides. However, nanoparticles with different surface charges equally well stimulate coagulation at lower concentrations. This stimulation may be an effect which is not directly related to the surface charge.
The interaction between lipid bilayers in water has been intensively studied over the last decades. Osmotic stress was applied to evaluate the forces between two approaching lipid bilayers in aqueous solution. The force–distance relation between lipid mono- or bilayers deposited on mica sheets using a surface force apparatus (SFA) was also measured. Lipid stabilised foam films offer another possibility to study the interactions between lipid monolayers. These films can be prepared comparatively easy with very good reproducibility. Foam films consist usually of two adsorbed surfactant monolayers separated by a layer of the aqueous solution from which the film is created. Their thickness can be conveniently measured using microinterferometric techniques. Studies with foam films deliver valuable information on the interactions between lipid membranes and especially their stability and permeability. Presenting inverse black lipid membrane (BLM) foam films supply information about the properties of the lipid self-organisation in bilayers. The present paper summarises results on microscopic lipid stabilised foam films by measuring their thickness and contact angle. Most of the presented results concern foam films prepared from dispersions of the zwitterionic lipid 1,2-dimyristoyl-sn-glycero-3-phosphorylcholine (DMPC) and some of its mixtures with the anionic lipid — 1,2-dimyristoyl-sn-glycero-3-[phospho-rac-(1-glycerol)] (DMPG).
The strength of the long range and short range forces between the lipid layers is discussed. The van der Waals attractive force is calculated. The electrostatic repulsive force is estimated from experiments at different electrolyte concentrations (NaCl, CaCl2) or by modification of the electrostatic double layer surface potential by incorporating charged lipids in the lipid monolayers. The short range interactions are studied and modified by using small carbohydrates (fructose and sucrose), ethanol (EtOH) or dimethylsulfoxide (DMSO). Some results are compared with the structure of lipid monolayers deposited at the liquid/air interface (monolayers spread in Langmuir trough), which are one of most studied biomembrane model system. The comparison between the film thickness and the free energy of film formation is used to estimate the contribution of the different components of the disjoining pressure to the total interaction in the film and their dependence on the composition of the film forming solution.
Medical implants play a central role in modern medicine and both, naturally derived and synthetic materials have been explored as biomaterials for such devices. However, when implanted into living tissue, most materials initiate a host response. In addition, implants often cause bacterial infections leading to complications. Polyelectrolyte multilayer (PEM) coatings can be used for functionalization of medical implants improving the implant integration and reducing foreign body reactions. Some PEMs are also known to show antibacterial properties. We developed a PEM coating suggesting that it can decrease the risk of bacterial infections occurring after implantation while being highly biocompatible. We applied two different standard tests for evaluating the PEM’s antibacterial properties, the ISO norm (ISO 22196) and one ASTM norm (ASTM E2180) test. We found a reduction of bacterial growth on the PEM but to a different degree depending on the testing method. This result demonstrates the need for defining proper method to evaluate antibacterial properties of surface coatings.
Controlling the surface properties and structure of thin nanosized coatings is of primary importance in diverse engineering and medical applications. Here we report on how the nanostructure, growth mechanism, thickness, roughness, and hydrophilicity of nanocomposites composed of weak natural or strong synthetic polyelectrolytes (PE) can be tailored by graphene oxide (GO) doping. GO reverses the build‐up mechanism affecting the internal structure and the hydrophilicity in a way depending on the type of the PE‐matrix. The extent of GO‐adsorption and its impact on the surface morphology was found to be independent on the type of the underlying PE‐matrix. The nanostructure of the hybrid films is not significantly altered when a single surface‐exposed GO‐layer is deposited, while increasing the number of embedded GO‐layers leads to pronounced surface heterogeneity. These results are expected to have valuable impact on the construction strategies of coatings with tunable surface properties.
Introduction: Bioresorbable collagenous barrier membranes are used to prevent premature soft tissue ingrowth and to allow bone regeneration. For volume stable indications, only non-absorbable synthetic materials are available. This study investigates a new bioresorbable hydrofluoric acid (HF)-treated magnesium (Mg) mesh in a native collagen membrane for volume stable situations. Materials and Methods: HF-treated and untreated Mg were compared in direct and indirect cytocompatibility assays. In vivo, 18 New Zealand White Rabbits received each four 8 mm calvarial defects and were divided into four groups: (a) HF-treated Mg mesh/collagen membrane, (b) untreated Mg mesh/collagen membrane (c) collagen membrane and (d) sham operation. After 6, 12 and 18 weeks, Mg degradation and bone regeneration was measured using radiological and histological methods. Results: In vitro, HF-treated Mg showed higher cytocompatibility. Histopathologically, HF-Mg prevented gas cavities and was degraded by mononuclear cells via phagocytosis up to 12 weeks. Untreated Mg showed partially significant more gas cavities and a fibrous tissue reaction. Bone regeneration was not significantly different between all groups. Discussion and Conclusions: HF-Mg meshes embedded in native collagen membranes represent a volume stable and biocompatible alternative to the non-absorbable synthetic materials. HF-Mg shows less corrosion and is degraded by phagocytosis. However, the application of membranes did not result in higher bone regeneration.
The present publication reports the purification effort of two natural bone blocks, that is, an allogeneic bone block (maxgraft®, botiss biomaterials GmbH, Zossen, Germany) and a xenogeneic block (SMARTBONE®, IBI S.A., Mezzovico Vira, Switzerland) in addition to previously published results based on histology. Furthermore, specialized scanning electron microscopy (SEM) and in vitro analyses (XTT, BrdU, LDH) for testing of the cytocompatibility based on ISO 10993-5/-12 have been conducted. The microscopic analyses showed that both bone blocks possess a trabecular structure with a lamellar subarrangement. In the case of the xenogeneic bone block, only minor remnants of collagenous structures were found, while in contrast high amounts of collagen were found associated with the allogeneic bone matrix. Furthermore, only island-like remnants of the polymer coating in case of the xenogeneic bone substitute seemed to be detectable. Finally, no remaining cells or cellular remnants were found in both bone blocks. The in vitro analyses showed that both bone blocks are biocompatible. Altogether, the purification level of both bone blocks seems to be favorable for bone tissue regeneration without the risk for inflammatory responses or graft rejection. Moreover, the analysis of the maxgraft® bone block showed that the underlying purification process allows for preserving not only the calcified bone matrix but also high amounts of the intertrabecular collagen matrix.
The aim of this study was to predefine the pore structure of β-tricalcium phosphate (β-TCP) scaffolds with different macro pore sizes (500, 750, and 1000 µm), to characterize β-TCP scaffolds, and to investigate the growth behavior of cells within these scaffolds. The lead structures for directional bone growth (sacrificial structures) were produced from polylactide (PLA) using the fused deposition modeling techniques. The molds were then filled with β-TCP slurry and sintered at 1250° C, whereby the lead structures (voids) were burnt out. The scaffolds were mechanically characterized (native and after incubation in simulated body fluid (SBF) for 28 d). In addition, biocompatibility was investigated by live/dead, cell proliferation and lactate dehydrogenase assays.
Polyelectrolyte multilayer coatings (PEM) are prepared by alternative layer-by-layer deposition of cationic and anionic polyelectrolyte monolayers on charged surfaces. The thickness of the coatings ranges from nm to few μm. Their properties such as roughness, stiffness, surface charge and surface energy can be precisely tuned to fulfil different technical or biological requirements. The coating process is based on self-assembly of polyelectrolytes. Advantages of these coatings are their easy handling, no harsh chemistry and the possibility for coatings on complex geometries. The PEM coatings can be prepared from a variety of suitable polyelectrolytes. Their stability varies from very durable PEM coatings that are only soluble in strong solvents to quickly degradable, which may be applied as drug release system. One example of such a degradable PEM system is the one based on the polyelectrolyte pair Hyaluronan (HA) and Chitosan (CHI). These biopolymers originate from natural sources and show low toxicity towards human cells. However, HA/CHI multilayers show only weak adhesiveness for human umbilical vein endothelial cells (HUVEC). In this article, we summarize our approaches to enhance the HA/CHI multilayer by incorporation of a non-polymer substance –graphene oxide– to improve the cell adhesion and keep such properties as low cytotoxicity and biodegradability. Different approaches for incorporation of graphene oxide were performed and the cellular adhesion was tested by metabolic assay.
High moisture permeability, excellent mechanical properties in a wet state, high water-holding capability, and high exudate absorption make bacterial nanocellulose (BNC) a favorable candidate for biomedical device production, especially wound dressings. The lack of antibacterial activity and healing-promoting ability are the main drawbacks that limit its wide application. Pullulan (Pul) is a nontoxic polymer that can promote wound healing. Zinc oxide nanoparticles (ZnO-NPs) are well-known as a safe antibacterial agent. In this study, aminoalkylsilane was chemically grafted on a BNC membrane (A-g-BNC) and used as a bridge to combine BNC with Pul-ZnO-NPs hybrid electrospun nanofibers. FTIR results confirmed the successful production of A-g-BNC/Pul-ZnO. The obtained dressing demonstrated blood clotting performance better than that of BNC. The dressing showed an ability to release ZnO, and its antibacterial activity was up to 5 log values higher than that of BNC. The cytotoxicity of the dressing toward L929 fibroblast cells clearly showed safety due to the proliferation of fibroblast cells. The animal test in a rat model indicated faster healing and re-epithelialization, small blood vessel formation, and collagen synthesis in the wounds covered by A-g-BNC/Pul-ZnO. The new functional dressing, fabricated with a cost-effective and easy method, not only showed excellent antibacterial activity but could also accelerate wound healing.
Controlled adhesion of HUVEC on polyelectrolyte multilayers by regulation of coating conditions
(2021)
Adhesion of host cells on the surface of implants is necessary for a healthy ingrowth of the implanted material. One possibility of surface modification is the coating of the implant with a second material with advantageous physical–chemical surface properties for the biological system. The coverage with blood proteins takes place immediately after implantation. It is followed by host–cell interaction on the surface. In this work, the effect of polyelectrolyte multilayer coatings (PEMs) on adhesion and activity of human umbilical vein endothelial cells (HUVECs) was studied. The PEMs were formed from poly(styrenesulfonate) (PSS) and poly(allylamine hydrochloride) (PAH) from solutions with different concentrations of NaCl varying between 0 and 1.0 M. The adhesion of HUVEC and their viability on the PEM is related to the amount of adsorbed proteins from the applied cell growth medium. The amount of adsorbed proteins is controlled not only by the surface charge but also by the internal excess charge of the PEM. The internal excess charge of the PEM was controlled by changing the electrolyte concentration in the deposition solutions.
At the beginning of 2022, Frontiers in Bioengineering and Biotechnology - Biomaterials Section has published a Research Topic on “Functional Surfaces and Biomaterials.” The aim of this Research Topic is to summarize the current state of research and development in the field of functional surfaces and biomaterials with a particular focus on biotechnological and medical applications.
The guest editorial team would like to thank all colleagues from around the world who submitted their reviews and research articles for the Research Topic. By the end of August 2022, we have successfully collected 20 articles by 138 participating authors following the peer review process. We also tried to select manuscripts from different research areas to cover the most relevant Research Topic of interest, from drug delivery systems to bone tissue engineering to biosensors and general aspects in biomedicine. By the end of December, the 20 articles had been viewed for more than 21000 times with downloads more than 4,000 times, and 11 articles have reached more than 1,000 views.
Cytocompatibility analyses of new implant materials or biomaterials are not only prescribed by the Medical Device Regulation (MDR), as defined in the DIN ISO Norm 10993-5 and -12, but are also increasingly replacing animal testing. In this context, jellyfish collagen has already been established as an alternative to mammalian collagen in different cell culture conditions, but a lack of knowledge exists about its applicability for cytocompatibility analyses of biomaterials. Thus, the present study was conducted to compare well plates coated with collagen type 0 derived from Rhizostoma pulmo with plates coated with bovine and porcine collagen. The coated well plates were analysed in vitro for their cytocompatibility, according to EN ISO 10993-5/−12, using both L929 fibroblasts and MC3T3 pre-osteoblasts. Thereby, the coated well plates were compared, using established materials as positive controls and a cytotoxic material, RM-A, as a negative control. L929 cells exhibited a significantly higher viability (#### p < 0.0001), proliferation (## p < 0.01), and a lower cytotoxicity (## p < 0.01 and # p < 0.05)) in the Jellagen® group compared to the bovine and porcine collagen groups. MC3T3 cells showed similar viability and acceptable proliferation and cytotoxicity in all collagen groups. The results of the present study revealed that the coating of well plates with collagen Type 0 derived from R. pulmo leads to comparable results to the case of well plates coated with mammalian collagens. Therefore, it is fully suitable for the in vitro analyses of the cytocompatibility of biomaterials or medical devices.
Escherichia coli (E. coli) is considered the most common life-threatening infectious bacteria in our daily life and poses a major challenge to human health. However, antibiotics frequently overused and misused has triggered increased multidrug resistance, hinders therapeutic outcomes, and causes higher mortalities. Herein, we addressed near-infrared (NIR) laser-excited human serum albumin (HSA) mediated graphene oxide loaded palladium nano-dots (HSA-GO-Pd) that can effectively combat Gram-negative E. coli in vitro. NIR laser-excited designed hybrid material highly generates singlet oxygen and hydroxyl radical by electron spin-resonance (ESR) analysis. Transmission electron microscope (TEM) images show small spherical sizes PdNPs on the surface of GO nano-sheets. The zeta (ζ) potential study indicates that in an aqueous medium, the average PdNPs size and surface capped charge comes from human body protein (HSA), HSA-GO-Pd is 5–8 nm, and +25 mV, respectively. The spectroscopic characterization reveals that in the synthesized HSA-GO-Pd nanocomposite, PdNPs successfully well-dispersed decorated on the surface of graphene oxide. The as-synthesized HSA-GO-Pd shows excellent antibacterial activity against gram-negative pathogen by killing 95% bacteria within 5 h. HSA-GO-Pd having very biocompatible and shows significant antibacterial activities. Owing to their intense photothermal conversation potential, low toxicity to normal cells, the as-addressed hybrid (HSA-GO-Pd) combined with NIR-irradiation will catch up valuable insight into the effective ablation of pathogenic bacteria.
Despite its success against cancer, photothermal therapy (PTT) (>50 °C) suffers from several limitations such as triggering inflammation and facilitating immune escape and metastasis and also damage to the surrounding normal cells. Mild-temperature PTT has been proposed to override these shortcomings. We developed a nanosystem using HepG2 cancer cell membrane-cloaked zinc glutamate-modified Prussian blue nanoparticles with triphenylphosphine-conjugated lonidamine (HmPGTL NPs). This innovative approach achieved an efficient mild-temperature PTT effect by downregulating the production of intracellular ATP. This disrupts a section of heat shock proteins that cushion cancer cells against heat. The physicochemical properties, anti-tumor efficacy, and mechanisms of HmPGTL NPs both in vitro and in vivo were investigated. Moreover, the nanoparticles cloaked with the HepG2 cell membrane substantially prolonged the circulation time in vivo. Overall, the designed nanocomposites enhance the efficacy of mild-temperature PTT by disrupting the production of ATP in cancer cells. Thus, we anticipate that the mild-temperature PTT nanosystem will certainly present its enormous potential in various biomedical applications.
The physicochemical properties of synthetically produced bone substitute materials (BSM) have a major impact on biocompatibility. This affects bony tissue integration, osteoconduction, as well as the degradation pattern and the correlated inflammatory tissue responses including macrophages and multinucleated giant cells (MNGCs). Thus, influencing factors such as size, special surface morphologies, porosity, and interconnectivity have been the subject of extensive research. In the present publication, the influence of the granule size of three identically manufactured bone substitute granules based on the technology of hydroxyapatite (HA)-forming calcium phosphate cements were investigated, which includes the inflammatory response in the surrounding tissue and especially the induction of MNGCs (as a parameter of the material degradation). For the in vivo study, granules of three different size ranges (small = 0.355–0.5 mm; medium = 0.5–1 mm; big = 1–2 mm) were implanted in the subcutaneous connective tissue of 45 male BALB/c mice. At 10, 30, and 60 days post implantationem, the materials were explanted and histologically processed. The defect areas were initially examined histopathologically. Furthermore, pro- and anti-inflammatory macrophages were quantified histomorphometrically after their immunohistochemical detection. The number of MNGCs was quantified as well using a histomorphometrical approach. The results showed a granule size-dependent integration behavior. The surrounding granulation tissue has passivated in the groups of the two bigger granules at 60 days post implantationem including a fibrotic encapsulation, while a granulation tissue was still present in the group of the small granules indicating an ongoing cell-based degradation process. The histomorphometrical analysis showed that the number of proinflammatory macrophages was significantly increased in the small granules at 60 days post implantationem. Similarly, a significant increase of MNGCs was detected in this group at 30 and 60 days post implantationem. Based on these data, it can be concluded that the integration and/or degradation behavior of synthetic bone substitutes can be influenced by granule size.
A full understanding of the relationship between surface properties, protein adsorption, and immune responses is lacking but is of great interest for the design of biomaterials with desired biological profiles. In this study, polyelectrolyte multilayer (PEM) coatings with gradient changes in surface wettability were developed to shed light on how this impacts protein adsorption and immune response in the context of material biocompatibility. The analysis of immune responses by peripheral blood mononuclear cells to PEM coatings revealed an increased expression of proinflammatory cytokines tumor necrosis factor (TNF)-α, macrophage inflammatory protein (MIP)-1β, monocyte chemoattractant protein (MCP)-1, and interleukin (IL)-6 and the surface marker CD86 in response to the most hydrophobic coating, whereas the most hydrophilic coating resulted in a comparatively mild immune response. These findings were subsequently confirmed in a cohort of 24 donors. Cytokines were produced predominantly by monocytes with a peak after 24 h. Experiments conducted in the absence of serum indicated a contributing role of the adsorbed protein layer in the observed immune response. Mass spectrometry analysis revealed distinct protein adsorption patterns, with more inflammation-related proteins (e.g., apolipoprotein A-II) present on the most hydrophobic PEM surface, while the most abundant protein on the hydrophilic PEM (apolipoprotein A-I) was related to anti-inflammatory roles. The pathway analysis revealed alterations in the mitogen-activated protein kinase (MAPK)-signaling pathway between the most hydrophilic and the most hydrophobic coating. The results show that the acute proinflammatory response to the more hydrophobic PEM surface is associated with the adsorption of inflammation-related proteins. Thus, this study provides insights into the interplay between material wettability, protein adsorption, and inflammatory response and may act as a basis for the rational design of biomaterials.
Collagen-based barrier membranes are an essential component in Guided Bone Regeneration (GBR) procedures. They act as cell-occlusive devices that should maintain a micromilieu where bone tissue can grow, which in turn provides a stable bed for prosthetic implantation. However, the standing time of collagen membranes has been a challenging area, as native membranes are often prematurely resorbed. Therefore, consolidation techniques, such as chemical cross-linking, have been used to enhance the structural integrity of the membranes, and by consequence, their standing time. However, these techniques have cytotoxic tendencies and can cause exaggerated inflammation and in turn, premature resorption, and material failures. However, tissues from different extraction sites and animals are variably cross-linked. For the present in vivo study, a new collagen membrane based on bovine dermis was extracted and compared to a commercially available porcine-sourced collagen membrane extracted from the pericardium. The membranes were implanted in Wistar rats for up to 60 days. The analyses included well-established histopathological and histomorphometrical methods, including histochemical and immunohistochemical staining procedures, to detect M1- and M2-macrophages as well as blood vessels. Initially, the results showed that both membranes remained intact up to day 30, while the bovine membrane was fragmented at day 60 with granulation tissue infiltrating the implantation beds. In contrast, the porcine membrane remained stable without signs of material-dependent inflammatory processes. Therefore, the bovine membrane showed a special integration pattern as the fragments were found to be overlapping, providing secondary porosity in combination with a transmembraneous vascularization. Altogether, the bovine membrane showed comparable results to the porcine control group in terms of biocompatibility and standing time. Moreover, blood vessels were found within the bovine membranes, which can potentially serve as an additional functionality of barrier membranes that conventional barrier membranes do not provide.
Reflectometry is known since long as an interferometric method which can be used to characterize surfaces and thin films regarding their structure and,to a certain degree,composition as well.Properties like layer structures,layer thickness,density,and interface roughness can be determined by fitting the obtained reflectivity data with an appropriate model using a recursive fitting routine. However,one major drawback of the reflectometric method is its restriction to planar surfaces.In this article we demonstrate an approach to apply X-ray and neutron reflectometry to curved surfaces by means of the example of bent bare and coated glass slides.We prove the possibility to observe all features like Fresnel decay,Kiessig fringes,Bragg peaks and off-specular scattering and are able to interpret the data using common fitting software and to derive quantitative results about roughness,layer thickness and internal structure. The proposed method has become practical due to the availability of high quality 2D-detectors. It opens up the option to explore many kinds and shapes of samples,which,due to their geometry,have not been in the focus of reflectometry techniques until now.
Polyelectrolyte multilayer (PEM) are thin polymeric films produced by alternating adsorption of positively and negatively charged polyelectrolytes (PE) on a substrate. These films are considered drug delivery agents as well as coating material for implants, due to their antibiofouling and biologically benign properties. For these reasons the film mechanical properties as well as response to mechanical stress are important measurement parameters. Especially intriguing is the correlation of the mechanical properties of PEM on macroscopic level with the structure of PEM on molecular level, which is addressed here for the first time. This study investigates PEM from PDADMA/PSS produced by spraying technique with neutron and X-ray reflectometry. Reflectometry technique provides precise information on thickness and density (i.e., electron density or scattering length density, respectively), and, this way, allows to conclude on changes in film composition. Thus, neutron and X-ray reflectometry technique is suitable to investigate the overall and the internal transformations, which PEM films might undergo upon exposure to mechanical load. During uniaxial elongation two regimes of PEM deformation can be observed: An elastic regime at small elongations (below ca. 0.2%), which is characterized by a reversible change of film thickness, and a plastic regime with a permanent change above this limit. Both regimes have in common, that the mechanical load induces an increase of the film thickness, which is accompanied by an uptake of water from the surrounding atmosphere. The strain causes a molecular rearrangement within the PEM-structure of stratified layers, which, even in elastic regime, is permanent, although the thickness change remains reversible.
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.