At the beginning of 2022, Frontiers in Bioengineering and Biotechnology - Biomaterials Section has published a Research Topic on “Functional Surfaces and Biomaterials.” The aim of this Research Topic is to summarize the current state of research and development in the field of functional surfaces and biomaterials with a particular focus on biotechnological and medical applications.
The guest editorial team would like to thank all colleagues from around the world who submitted their reviews and research articles for the Research Topic. By the end of August 2022, we have successfully collected 20 articles by 138 participating authors following the peer review process. We also tried to select manuscripts from different research areas to cover the most relevant Research Topic of interest, from drug delivery systems to bone tissue engineering to biosensors and general aspects in biomedicine. By the end of December, the 20 articles had been viewed for more than 21000 times with downloads more than 4,000 times, and 11 articles have reached more than 1,000 views.
Cytocompatibility analyses of new implant materials or biomaterials are not only prescribed by the Medical Device Regulation (MDR), as defined in the DIN ISO Norm 10993-5 and -12, but are also increasingly replacing animal testing. In this context, jellyfish collagen has already been established as an alternative to mammalian collagen in different cell culture conditions, but a lack of knowledge exists about its applicability for cytocompatibility analyses of biomaterials. Thus, the present study was conducted to compare well plates coated with collagen type 0 derived from Rhizostoma pulmo with plates coated with bovine and porcine collagen. The coated well plates were analysed in vitro for their cytocompatibility, according to EN ISO 10993-5/−12, using both L929 fibroblasts and MC3T3 pre-osteoblasts. Thereby, the coated well plates were compared, using established materials as positive controls and a cytotoxic material, RM-A, as a negative control. L929 cells exhibited a significantly higher viability (#### p < 0.0001), proliferation (## p < 0.01), and a lower cytotoxicity (## p < 0.01 and # p < 0.05)) in the Jellagen® group compared to the bovine and porcine collagen groups. MC3T3 cells showed similar viability and acceptable proliferation and cytotoxicity in all collagen groups. The results of the present study revealed that the coating of well plates with collagen Type 0 derived from R. pulmo leads to comparable results to the case of well plates coated with mammalian collagens. Therefore, it is fully suitable for the in vitro analyses of the cytocompatibility of biomaterials or medical devices.
Escherichia coli (E. coli) is considered the most common life-threatening infectious bacteria in our daily life and poses a major challenge to human health. However, antibiotics frequently overused and misused has triggered increased multidrug resistance, hinders therapeutic outcomes, and causes higher mortalities. Herein, we addressed near-infrared (NIR) laser-excited human serum albumin (HSA) mediated graphene oxide loaded palladium nano-dots (HSA-GO-Pd) that can effectively combat Gram-negative E. coli in vitro. NIR laser-excited designed hybrid material highly generates singlet oxygen and hydroxyl radical by electron spin-resonance (ESR) analysis. Transmission electron microscope (TEM) images show small spherical sizes PdNPs on the surface of GO nano-sheets. The zeta (ζ) potential study indicates that in an aqueous medium, the average PdNPs size and surface capped charge comes from human body protein (HSA), HSA-GO-Pd is 5–8 nm, and +25 mV, respectively. The spectroscopic characterization reveals that in the synthesized HSA-GO-Pd nanocomposite, PdNPs successfully well-dispersed decorated on the surface of graphene oxide. The as-synthesized HSA-GO-Pd shows excellent antibacterial activity against gram-negative pathogen by killing 95% bacteria within 5 h. HSA-GO-Pd having very biocompatible and shows significant antibacterial activities. Owing to their intense photothermal conversation potential, low toxicity to normal cells, the as-addressed hybrid (HSA-GO-Pd) combined with NIR-irradiation will catch up valuable insight into the effective ablation of pathogenic bacteria.
Despite its success against cancer, photothermal therapy (PTT) (>50 °C) suffers from several limitations such as triggering inflammation and facilitating immune escape and metastasis and also damage to the surrounding normal cells. Mild-temperature PTT has been proposed to override these shortcomings. We developed a nanosystem using HepG2 cancer cell membrane-cloaked zinc glutamate-modified Prussian blue nanoparticles with triphenylphosphine-conjugated lonidamine (HmPGTL NPs). This innovative approach achieved an efficient mild-temperature PTT effect by downregulating the production of intracellular ATP. This disrupts a section of heat shock proteins that cushion cancer cells against heat. The physicochemical properties, anti-tumor efficacy, and mechanisms of HmPGTL NPs both in vitro and in vivo were investigated. Moreover, the nanoparticles cloaked with the HepG2 cell membrane substantially prolonged the circulation time in vivo. Overall, the designed nanocomposites enhance the efficacy of mild-temperature PTT by disrupting the production of ATP in cancer cells. Thus, we anticipate that the mild-temperature PTT nanosystem will certainly present its enormous potential in various biomedical applications.
The physicochemical properties of synthetically produced bone substitute materials (BSM) have a major impact on biocompatibility. This affects bony tissue integration, osteoconduction, as well as the degradation pattern and the correlated inflammatory tissue responses including macrophages and multinucleated giant cells (MNGCs). Thus, influencing factors such as size, special surface morphologies, porosity, and interconnectivity have been the subject of extensive research. In the present publication, the influence of the granule size of three identically manufactured bone substitute granules based on the technology of hydroxyapatite (HA)-forming calcium phosphate cements were investigated, which includes the inflammatory response in the surrounding tissue and especially the induction of MNGCs (as a parameter of the material degradation). For the in vivo study, granules of three different size ranges (small = 0.355–0.5 mm; medium = 0.5–1 mm; big = 1–2 mm) were implanted in the subcutaneous connective tissue of 45 male BALB/c mice. At 10, 30, and 60 days post implantationem, the materials were explanted and histologically processed. The defect areas were initially examined histopathologically. Furthermore, pro- and anti-inflammatory macrophages were quantified histomorphometrically after their immunohistochemical detection. The number of MNGCs was quantified as well using a histomorphometrical approach. The results showed a granule size-dependent integration behavior. The surrounding granulation tissue has passivated in the groups of the two bigger granules at 60 days post implantationem including a fibrotic encapsulation, while a granulation tissue was still present in the group of the small granules indicating an ongoing cell-based degradation process. The histomorphometrical analysis showed that the number of proinflammatory macrophages was significantly increased in the small granules at 60 days post implantationem. Similarly, a significant increase of MNGCs was detected in this group at 30 and 60 days post implantationem. Based on these data, it can be concluded that the integration and/or degradation behavior of synthetic bone substitutes can be influenced by granule size.
A full understanding of the relationship between surface properties, protein adsorption, and immune responses is lacking but is of great interest for the design of biomaterials with desired biological profiles. In this study, polyelectrolyte multilayer (PEM) coatings with gradient changes in surface wettability were developed to shed light on how this impacts protein adsorption and immune response in the context of material biocompatibility. The analysis of immune responses by peripheral blood mononuclear cells to PEM coatings revealed an increased expression of proinflammatory cytokines tumor necrosis factor (TNF)-α, macrophage inflammatory protein (MIP)-1β, monocyte chemoattractant protein (MCP)-1, and interleukin (IL)-6 and the surface marker CD86 in response to the most hydrophobic coating, whereas the most hydrophilic coating resulted in a comparatively mild immune response. These findings were subsequently confirmed in a cohort of 24 donors. Cytokines were produced predominantly by monocytes with a peak after 24 h. Experiments conducted in the absence of serum indicated a contributing role of the adsorbed protein layer in the observed immune response. Mass spectrometry analysis revealed distinct protein adsorption patterns, with more inflammation-related proteins (e.g., apolipoprotein A-II) present on the most hydrophobic PEM surface, while the most abundant protein on the hydrophilic PEM (apolipoprotein A-I) was related to anti-inflammatory roles. The pathway analysis revealed alterations in the mitogen-activated protein kinase (MAPK)-signaling pathway between the most hydrophilic and the most hydrophobic coating. The results show that the acute proinflammatory response to the more hydrophobic PEM surface is associated with the adsorption of inflammation-related proteins. Thus, this study provides insights into the interplay between material wettability, protein adsorption, and inflammatory response and may act as a basis for the rational design of biomaterials.
Collagen-based barrier membranes are an essential component in Guided Bone Regeneration (GBR) procedures. They act as cell-occlusive devices that should maintain a micromilieu where bone tissue can grow, which in turn provides a stable bed for prosthetic implantation. However, the standing time of collagen membranes has been a challenging area, as native membranes are often prematurely resorbed. Therefore, consolidation techniques, such as chemical cross-linking, have been used to enhance the structural integrity of the membranes, and by consequence, their standing time. However, these techniques have cytotoxic tendencies and can cause exaggerated inflammation and in turn, premature resorption, and material failures. However, tissues from different extraction sites and animals are variably cross-linked. For the present in vivo study, a new collagen membrane based on bovine dermis was extracted and compared to a commercially available porcine-sourced collagen membrane extracted from the pericardium. The membranes were implanted in Wistar rats for up to 60 days. The analyses included well-established histopathological and histomorphometrical methods, including histochemical and immunohistochemical staining procedures, to detect M1- and M2-macrophages as well as blood vessels. Initially, the results showed that both membranes remained intact up to day 30, while the bovine membrane was fragmented at day 60 with granulation tissue infiltrating the implantation beds. In contrast, the porcine membrane remained stable without signs of material-dependent inflammatory processes. Therefore, the bovine membrane showed a special integration pattern as the fragments were found to be overlapping, providing secondary porosity in combination with a transmembraneous vascularization. Altogether, the bovine membrane showed comparable results to the porcine control group in terms of biocompatibility and standing time. Moreover, blood vessels were found within the bovine membranes, which can potentially serve as an additional functionality of barrier membranes that conventional barrier membranes do not provide.
Reflectometry is known since long as an interferometric method which can be used to characterize surfaces and thin films regarding their structure and,to a certain degree,composition as well.Properties like layer structures,layer thickness,density,and interface roughness can be determined by fitting the obtained reflectivity data with an appropriate model using a recursive fitting routine. However,one major drawback of the reflectometric method is its restriction to planar surfaces.In this article we demonstrate an approach to apply X-ray and neutron reflectometry to curved surfaces by means of the example of bent bare and coated glass slides.We prove the possibility to observe all features like Fresnel decay,Kiessig fringes,Bragg peaks and off-specular scattering and are able to interpret the data using common fitting software and to derive quantitative results about roughness,layer thickness and internal structure. The proposed method has become practical due to the availability of high quality 2D-detectors. It opens up the option to explore many kinds and shapes of samples,which,due to their geometry,have not been in the focus of reflectometry techniques until now.
Polyelectrolyte multilayer (PEM) are thin polymeric films produced by alternating adsorption of positively and negatively charged polyelectrolytes (PE) on a substrate. These films are considered drug delivery agents as well as coating material for implants, due to their antibiofouling and biologically benign properties. For these reasons the film mechanical properties as well as response to mechanical stress are important measurement parameters. Especially intriguing is the correlation of the mechanical properties of PEM on macroscopic level with the structure of PEM on molecular level, which is addressed here for the first time. This study investigates PEM from PDADMA/PSS produced by spraying technique with neutron and X-ray reflectometry. Reflectometry technique provides precise information on thickness and density (i.e., electron density or scattering length density, respectively), and, this way, allows to conclude on changes in film composition. Thus, neutron and X-ray reflectometry technique is suitable to investigate the overall and the internal transformations, which PEM films might undergo upon exposure to mechanical load. During uniaxial elongation two regimes of PEM deformation can be observed: An elastic regime at small elongations (below ca. 0.2%), which is characterized by a reversible change of film thickness, and a plastic regime with a permanent change above this limit. Both regimes have in common, that the mechanical load induces an increase of the film thickness, which is accompanied by an uptake of water from the surrounding atmosphere. The strain causes a molecular rearrangement within the PEM-structure of stratified layers, which, even in elastic regime, is permanent, although the thickness change remains reversible.
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.