Refine
Document Type
- Journal article (36)
- Book chapter (1)
Language
- English (37)
Is part of the Bibliography
- yes (37)
Institute
- Life Sciences (37)
Publisher
- Elsevier (7)
- MDPI (7)
- American Chemical Society (6)
- De Gruyter (5)
- Wiley (5)
- IIAR (2)
- BAN (1)
- Frontiers Media (1)
- Pan Stanford Publishing (1)
- Royal Society of Chemistry (1)
Cytocompatibility analyses of new implant materials or biomaterials are not only prescribed by the Medical Device Regulation (MDR), as defined in the DIN ISO Norm 10993-5 and -12, but are also increasingly replacing animal testing. In this context, jellyfish collagen has already been established as an alternative to mammalian collagen in different cell culture conditions, but a lack of knowledge exists about its applicability for cytocompatibility analyses of biomaterials. Thus, the present study was conducted to compare well plates coated with collagen type 0 derived from Rhizostoma pulmo with plates coated with bovine and porcine collagen. The coated well plates were analysed in vitro for their cytocompatibility, according to EN ISO 10993-5/−12, using both L929 fibroblasts and MC3T3 pre-osteoblasts. Thereby, the coated well plates were compared, using established materials as positive controls and a cytotoxic material, RM-A, as a negative control. L929 cells exhibited a significantly higher viability (#### p < 0.0001), proliferation (## p < 0.01), and a lower cytotoxicity (## p < 0.01 and # p < 0.05)) in the Jellagen® group compared to the bovine and porcine collagen groups. MC3T3 cells showed similar viability and acceptable proliferation and cytotoxicity in all collagen groups. The results of the present study revealed that the coating of well plates with collagen Type 0 derived from R. pulmo leads to comparable results to the case of well plates coated with mammalian collagens. Therefore, it is fully suitable for the in vitro analyses of the cytocompatibility of biomaterials or medical devices.
Papermaking waste liquid (black liquor) is a serious source of water pollution worldwide. The subsequent treatment of it is very difficult cause it contains a large amount of lignin, inorganic salts, organic matter, and pigments, which lead to serious water pollution. Lignin is the main by-product of the paper industry and is the only natural aromatic recyclable resource. Its effective utilization rate is currently less than 3%. Therefore, how to effectively recycle lignin in papermaking waste liquid and further synthesize industrialized products is of great significance to the sustainable development and environmental protection. Besides, based on the shortage of petroleum resources in recent years, the application of biomass resources instead of petroleum resources in the industry is also an important issue. In this article, we explored the best optimal conditions for the oxypropylation and esterification of lignin, and prepared bio-bitumen based on modified lignin, and then applied it to the waterproof coating sheets. FTIR and mechanical properties (softening point, low-temperature flexibility, peel strength, etc.) were tested on the obtained waterproof coating sheets. The results show that the addition of modified lignin reduced the softening point and peel strength of the coating sheets. Interestingly, both oxypropylated lignin (OL) and esterified lignin (OEL) were very beneficial to resist the decrease in peel strength during the aging process, showing a significant improvement in the performance of the coating sheets after aging compared to the control.
In this article, liposome-based coatings aiming to control drug release from therapeutic soft contact lenses (SCLs) materials are analyzed. A PHEMA based hydrogel material loaded with levofloxacin is used as model system for this research. The coatings are formed by polyelectrolyte layers containing liposomes of 1,2-dimyristoyl-sn-glycero-3- phosphocholine (DMPC) and DMPC1cholesterol (DMPC1 CHOL). The effect of friction and temperature on the drug release is investigated. The aim of the friction tests is to simulate the blinking of the eyelid in order to verify if the SCLs materials coated with liposomes are able to keep their properties, in particular the drug release ability. It was observed that under the study conditions, friction did not affect significantly the drug release from the liposome coated PHEMA material. In contrast, increasing the temperature of release leads to an increase of the drug diffusion rate through the hydrogel. This phenomenon is recorded both in the control and in the coated samples.
At the beginning of 2022, Frontiers in Bioengineering and Biotechnology - Biomaterials Section has published a Research Topic on “Functional Surfaces and Biomaterials.” The aim of this Research Topic is to summarize the current state of research and development in the field of functional surfaces and biomaterials with a particular focus on biotechnological and medical applications.
The guest editorial team would like to thank all colleagues from around the world who submitted their reviews and research articles for the Research Topic. By the end of August 2022, we have successfully collected 20 articles by 138 participating authors following the peer review process. We also tried to select manuscripts from different research areas to cover the most relevant Research Topic of interest, from drug delivery systems to bone tissue engineering to biosensors and general aspects in biomedicine. By the end of December, the 20 articles had been viewed for more than 21000 times with downloads more than 4,000 times, and 11 articles have reached more than 1,000 views.
Polymeric micelle-like nanoparticles have demonstrated effectiveness for the delivery of some poorly soluble or hydrophobic anticancer drugs. In this study, a hydrophobic moiety, deoxycholic acid (DCA) was first bonded on a polysaccharide, chitosan (CS), for the preparation of amphiphilic chitosan (CS-DCA), which was further modified with a cationic glycidyltrimethylammounium chloride (GTMAC) to form a novel soluble chitosan derivative (HT-CS-DCA). The cationic amphiphilic HT-CS-DCA was easily self-assembled to micelle-like nanoparticles about 200 nm with narrow size distribution (PDI 0.08–0.18). The zeta potential of nanoparticles was in the range of 14 to 24 mV, indicating higher positive charges. Then, doxorubicin (DOX), an anticancer drug with poor solubility, was entrapped into HT-CS-DCA nanoparticles. The DOX release test was performed in PBS (pH 7.4) at 37 °C, and the results showed that there was no significant burst release in the first two hours, and the cumulative release increased steadily and slowly in the following hours. HT-CS-DCA nanoparticles loaded with DOX could easily enter into MCF-7 cells, as observed by a confocal microscope. As a result, DOX-loaded HT-CS-DCA nanoparticles demonstrated a significant inhibition activity on MCF-7 growth without obvious cellular toxicity in comparison with blank nanoparticles. Therefore, the anticancer efficacy of these cationic HT-CS-DCA nanoparticles showed great promise for the delivery of DOX in cancer therapy.
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.
Background/Aim: The aim of this study was the development of a new osteoconductivity index to determine the bone healing capacities of bone substitute materials (BSM) on the basis of 3D microcomputed tomographic (μ-CT) data. Materials and Methods: Sinus biopsies were used for the comparative analysis of the integration behavior of two xenogeneic BSM (cerabone® and Bio Oss®). 3D μ-CT and data sets from histomorphometrical measurements based on 2D histological slices were used to measure the bone-material-contact and the tissue distribution within the biopsies. The tissue reactions to both BSM were microscopically analyzed. Results: The 3D and 2D results of the osteoconductivity measurements showed comparable material-bone contacts for both BSM, but the 2D data were significantly lower. The same results were found when tissue distribution was measured in both groups. The histopathological analysis showed comparative tissue reactions in both BSM. Conclusion: Osteoconductivity index is a reliable measurement parameter for determining the healing capacities of BSM. The observed differences between both measurement methods could be assigned to the resolution capacity of μ-CT data that did not allow for a precise interface distinction between both BSM and bone tissue. Histomorphometrical data based on histological slides still allow for a more exact evaluation.
Collagen-based barrier membranes are an essential component in Guided Bone Regeneration (GBR) procedures. They act as cell-occlusive devices that should maintain a micromilieu where bone tissue can grow, which in turn provides a stable bed for prosthetic implantation. However, the standing time of collagen membranes has been a challenging area, as native membranes are often prematurely resorbed. Therefore, consolidation techniques, such as chemical cross-linking, have been used to enhance the structural integrity of the membranes, and by consequence, their standing time. However, these techniques have cytotoxic tendencies and can cause exaggerated inflammation and in turn, premature resorption, and material failures. However, tissues from different extraction sites and animals are variably cross-linked. For the present in vivo study, a new collagen membrane based on bovine dermis was extracted and compared to a commercially available porcine-sourced collagen membrane extracted from the pericardium. The membranes were implanted in Wistar rats for up to 60 days. The analyses included well-established histopathological and histomorphometrical methods, including histochemical and immunohistochemical staining procedures, to detect M1- and M2-macrophages as well as blood vessels. Initially, the results showed that both membranes remained intact up to day 30, while the bovine membrane was fragmented at day 60 with granulation tissue infiltrating the implantation beds. In contrast, the porcine membrane remained stable without signs of material-dependent inflammatory processes. Therefore, the bovine membrane showed a special integration pattern as the fragments were found to be overlapping, providing secondary porosity in combination with a transmembraneous vascularization. Altogether, the bovine membrane showed comparable results to the porcine control group in terms of biocompatibility and standing time. Moreover, blood vessels were found within the bovine membranes, which can potentially serve as an additional functionality of barrier membranes that conventional barrier membranes do not provide.
Background/Aim: The aim of this study was the conception, production, material analysis and cytocompatibility analysis of a new collagen foam for medical applications. Materials and Methods: After the innovative production of various collagen sponges from bovine sources, the foams were analyzed ex vivo in terms of their structure (including pore size) and in vitro in terms of cytocompatibility according to EN ISO 10993-5/-12. In vitro, the collagen foams were compared with the established soft and hard tissue materials cerabone and Jason membrane (both botiss biomaterials GmbH, Zossen, Germany). Results: Collagen foams with different compositions were successfully produced from bovine sources. Ex vivo, the foams showed a stable and long-lasting primary structure quality with a bubble area of 1,000 to 2,000 μm2. In vitro, all foams showed sufficient cytocompatibility. Conclusion: Collagen sponges represent a promising material for hard and soft tissue regeneration. Future studies could focus on integrating and investigating different additives in the foams.
Hypothesis
The origin of negative surface charge at water/air interface is still not clear. The most probable origin is specific adsorption of OH− ions. From diffuse layer potential, we can evaluate the surface density of ions in the Stern layer which can be a measure for the specific adsorption of ions and determines whether the surface charge is solely due to the specific adsorption of OH− ions.
Experiments
Equilibrium thickness of foam films of pure water and aqueous solutions of NaCl, HCl, and NaOH was measured as a function of disjoining pressure for water and as a function of concentration for the aqueous solutions at 298.15 K. Quartz-glass cells thoroughly cleaned and immersed in pure water before use were used for the measurement.
Findings
Application of a modified Poisson-Boltzmann equation to the equilibrium film thickness gave the diffuse layer potential and the surface density of ions in the Stern layer. From the concentration dependence of the surface density, it was concluded that not only OH− ions but also Cl− ions and HCO3− and/or CO32− ions adsorb specifically at the water/air interface.