Refine
Document Type
- Journal article (27) (remove)
Is part of the Bibliography
- yes (27)
Institute
- Life Sciences (27)
Publisher
- De Gruyter (6)
- Elsevier (6)
- MDPI (5)
- Wiley (4)
- American Chemical Society (1)
- Hanser (1)
- Hindawi (1)
- JoVE (1)
- Springer (1)
- University of Technology and Economics, Department of Polymer Engineering (1)
The intelligent recycling of plastics waste is a major concern. Because of the widespread use of polyethylene terephtalate, considerable amounts of PET waste are generated that are ideally re-introduced into the material cycle by generating second generation products without loss of materials performance. Chemical recycling methods are often expensive and entail environmentally hazardous by-products. Established mechanical methods generally provide materials of reduced quality, leading to products of lower quality. These drawbacks can be avoided by the development of new recycling methods that provide materials of high quality in every step of the production cycle. In the present work, oligomeric ethylene terephthalate with defined degrees of polymerization and defined molecular weight is produced by melt-mixing PET with different quantities of adipic acid as an alternative pathway of recycling PET with respect to conventional methods, offering ecofriendly and economical aspects. Additionally, block-copolyesters of defined block length are designed from the oligomeric products.
Ethylene terephthalate and ethylene naphthalate oligomers of defined degree of polymerization were synthesized via chemical recycling of the parent polymers. The oligomers were used as defined building blocks for the preparation of novel block-co-polyesters having tailored sequence compositions. The sequence lengths were systematically varied using Design of Experiments. The dispersive surface energy and the specific desorption energy of the co-polymers were determined by inverse gas chromatography. The study shows that polyethylene terephthalate-polyethylene naphthalate (PET-PEN) block-co-polyesters of defined sequence lengths can be prepared. Furthermore, the specific and dispersive surface energies of the obtained block-co-polyesters showed a linear dependence on the oligomer molecular weight and it was possible to regulate and control their interfacial properties. In contrast, with the corresponding random-block-co-polyesters no such dependence was found. The synthesized block-co-polyesters could be used as polymeric modifying agents for stabilizing PET-PEN polymer blends.
Clay minerals play an increasingly important role as functional fillers and reinforcing materials for clay polymer nanocomposites (CPN) in advanced applications. Among the prerequisites necessary for polymer improvement by clay minerals are homogeneous and stable Distribution of the clay mineral throughout the CPN, good compatibility of the reinforcement with the Matrix component and suitable processability. Typically, clay minerals are surface-modified with organic interface active compounds like detergents or silanes to obtain favorable properties as filler. They are incorporated into the polymer matrix using manufacturing Equipment like extruders, batch reactors or other mixing machines. In order for the surface modification to survive the stresses and strains during incorporation, the modified clay minerals must display sufficient thermal and mechanical stability to retain the compatibilizing effect. In the present study, thermogravimetry was used in combination with isoconversional kinetic analysis to determine the thermal stability of a silane-modified clay mineral based on bentonite. These findings were compared with the stability of the same clay mineral that was only surfactant-modified. It was found that silane modification leads to significantly improved thermal stability, which depends strongly on the type of silane employed.
The chemical synthesis of polysiloxanes from monomeric starting materials involves a series of hydrolysis, condensation and modification reactions with complex monomeric and oligomeric reaction mixtures. Real-time monitoring and precise process control of the synthesis process is of great importance to ensure reproducible intermediates and products and can readily be performed by optical spectroscopy. In chemical reactions involving rapid and simultaneous functional group transformations and complex reaction mixtures, however, the spectroscopic signals are often ambiguous due to overlapping bands, shifting peaks and changing baselines. The univariate analysis of individual absorbance signals is hence often only of limited use. In contrast, batch modelling based on the multivariate analysis of the time course of principal components (PCs) derived from the reaction spectra provides a more efficient tool for real time monitoring. In batch modelling, not only single absorbance bands are used but information over a broad range of wavelengths is extracted from the evolving spectral fingerprints and used for analysis. Thereby, process control can be based on numerous chemical and morphological changes taking place during synthesis. “Bad” (or abnormal) batches can quickly be distinguished from “normal” ones by comparing the respective reaction trajectories in real time. In this work, FTIR spectroscopy was combined with multivariate data analysis for the in-line process characterization and batch modelling of polysiloxane formation. The synthesis was conducted under different starting conditions using various reactant concentrations. The complex spectral information was evaluated using chemometrics (principal component analysis, PCA). Specific spectral features at different stages of the reaction were assigned to the corresponding reaction steps. Reaction trajectories were derived based on batch modelling using a wide range of wavelengths. Subsequently, complexity was reduced again to the most relevant absorbance signals in order to derive a concept for a low-cost process spectroscopic set-up which could be used for real-time process monitoring and reaction control.
Thermoplastic polymers like ethylene-octene copolymer (EOC) may be grafted with silanes via reactive extrusion to enable subsequent crosslinking for advanced biomaterials manufacture. However, this reactive extrusion process is difficult to control and it is still challenging to reproducibly arrive at well-defined products. Moreover, high grafting degrees require a considerable excess of grafting reagent. A large proportion of the silane passes through the process without reacting and needs to be removed at great expense by subsequent purification. This results in unnecessarily high consumption of chemicals and a rather resource-inefficient process. It is thus desired to be able to define desired grafting degrees with optimum grafting efficiency by means of suitable process control. In this study, the continuous grafting of vinyltrimethoxysilane (VTMS) on ethylene-octene copolymer (EOC) via reactive extrusion was investigated. Successful grafting was verified and quantified by 1H-NMR spectroscopy. The effects of five process parameters and their synergistic interactions on grafting degree and grafting efficiency were determined using a face-centered experimental design (FCD). Response surface methodology (RSM) was applied to derive a causal process model and define process windows yielding arbitrary grafting degrees between <2 and >5% at a minimum waste of grafting agent. It was found that the reactive extrusion process was strongly influenced by several second-order interaction effects making this process difficult to control. Grafting efficiencies between 75 and 80% can be realized as long as grafting degrees <2% are admitted.
Polyurethane-bases block copolymers (TPCUs) are block-copolymers with systematically varied soft and hard segments. They have been suggested to serve as material for chondral implants in joint regeneration. Such applications may require the adhesion of chondrocytes to the implant surface, facilitating cell growth while keeping their phenotype. Thus, aims of this work were (1) to modify the surface of soft biostable polyurethane-based model implants (TPCU and TSiPCU) with high-molecular weight hyaluronic acid (HA) using an optimized multistep strategy of immobilization, and (2) to evaluate bioactivity of the modified TPCUs in vitro. Our results show no cytotoxic potential of the TPCUs. HAbioactive molecules (Mw =700kDa) were immobilized onto the polyurethane surface via polyethylenimine (PEI) spacers, and modifications were confirmed by several characterization methods. Tests with porcine chondrocytes indicated the potential of the TPCU-HA for inducing enhanced cell proliferation.
Here, we report the continuous peroxide-initiated grafting of vinyltrimethoxysilane (VTMS) onto a standard polyolefin by means of reactive extrusion to produce a functionalized liquid ethylene propylene copolymer (EPM). The effects of the process parameters governing the grafting reaction and their synergistic interactions are identified, quantified and used in a mathematical model of the extrusion process. As process variables the VTMS and peroxide concentrations and the extruder temperature setting were systematically studied for their influence on the grafting and the relative grafting degree using a face-centered central composite design (FCD). The grafting degree was quantified by 1H NMR spectroscopy. Response surface methodology (RSM) was used to calculate the most efficient grafting process in terms of chemical usage and graft yield. With the defined processing window, it was possible to make precise predictions about the grafting degree with at the same time highest possible relative degree of grafting.
Thermoplastic polycarbonate urethane elastomers (TPCU) are potential implant materials for treating degenerative joint diseases thanks to their adjustable rubber-like properties, their toughness, and their durability. We developed a water-containing high-molecular-weight sulfated hyaluronic acid-coating to improve the interaction of TPCU with the synovial fluid. It is suggested that trapped synovial fluid can act as a lubricant that reduces the friction forces and thus provides an enhanced abrasion resistance of TPCU implants. Aims of this work were (i) the development of a coating method for novel soft TPCU with high-molecular sulfated hyaluronic acid to increase the biocompatibility and (ii) the in vitro validation of the functionalized TPCUs in cell culture experiments.
Vitamin E (VitE) additives are important in treating osteoarthritis inclusive cartilage regeneration due to their antioxidant and anti-inflammatory properties. The present research study focuses on the ability of biological antioxidant VitE (alpha-tocopherol isoform) to reduce or minimize oxidative degradation of soft implantable polyurethane (PU) elastomers after extended periods of time (5 months) in vitro. The effect of the oxidation storage media on the morphology of the segmented PUs was evaluated by mechanical softening, crystallization and melting behavior of both soft and hard segments (SS, HS) using dynamic mechanical analysis (DMA). Bulk mechanical properties of the potential implant materials during ageing were predicted from comprehensive mechanical testing of the biomaterials under tension and compression cyclic loads. 5-months in vitro data suggest that the prepared siloxane-poly(carbonate urethane) formulations have sufficient resistance against degradation to be suitable materials for chondral long term bio-stable implants. Most importantly, the positive effect of incorporating VitE (0.5 or 1.0% w/w) as bio-antioxidant and lubricant on the bio-stability was observed for all PU types. VitE-additives protected the surface layer from erosion and cracking during chemical oxidation in vitro as well as from thermal oxidation during extrusion re-processing.