IGBT modules with anti-parallel FWDs are widely used in inductive load switching power applications, such as motor drive applications. Nowadays there is a continuous effort to increase the efficiency of such systems by decreasing their switching losses. This paper addresses the problems arising in the turn-on process of an IGBT working in hard-switching conditions. A method is proposed which achieves – contrary to most other approaches – a high switching speed and, at the same time, a low peak reverse-recovery current. This is done by applying an improved gate current waveform that is briefly lowered during the turn-on process. The proposed method achieves low switching losses. Its effectiveness is demonstrated by experimental results with IGBT modules for 600V and 1200V.
Advanced power semiconductors such as DMOS transistors are key components of modern power electronic systems. Recent discrete and integrated DMOS technologies have very low area-specific on-state resistances so that devices with small sizes can be chosen. However, their power dissipation can sometimes be large, for example in fault conditions, causing the device temperature to rise significantly. This can lead to excessive temperatures, reduced lifetime, and possibly even thermal runaway and subsequent destruction. Therefore, it is required to ensure already in the design phase that the temperature always remains in an acceptable range. This paper will show how self-heating in DMOS transistors can be experimentally determined with high accuracy. Further, it will be discussed how numerical electrothermal simulations can be carried out efficiently, allowing the accurate assessment of self-heating within a few minutes. The presented approach has been successfully verified experimentally for device temperatures exceeding 500 ◦C up to the onset of thermal runaway.
The loss contribution of a 2.3kW synchronous GaN-HEMT boost converter for an input voltage of 250V and an output voltage of 500V was analyzed. A simulation model which consists of two parts is introduced. First, a physics-based model is used to determine the switching losses. Then, a system simulation is applied to calculate the losses of the specific elements. This approach allows a fast and accurate system evaluation as required for further system optimization.
In this work, a hard- and a zero-voltage turn-on switching converter are compared. Measurements were performed to verify the simulation model, showing a good agreement. A peak efficiency of 99% was achieved for an output power of 1.4kW. Even with an output power above 400W, it was possible to obtain a system efficiency exceeding 98 %.
Influence of metallization layout on aging detector lifetime under cyclic thermo-mechanical stress
(2016)
The influence of the layout on early warning detectors in BCD technologies for metallization failure under cyclic thermo-mechanical stress was investigated. Different LDMOS transistors, with narrow or wide metal fingers and with or without embedded detectors, were used. The test structures were repeatedly stressed by pronounced self-heating until failure (a short circuit) was detected. The results show that the layout of the on-chip metallization has a large impact on the lifetime. A significant influence of the detectors on the lifetime was also observed, in our case causing a reduction of more than a factor of two, but only for the test structure with narrow metal fingers. The experimental results are explained by an efficient numerical thermo mechanical simulation approach, giving detailed insights into the strain distribution in the metal system. These results are important for aging detector design and, morever, for LDMOS on-chip metal layout in general.
This work investigates the electro-thermal behavior and failure mechanism of a 600V depletion-mode GaN HEMT by experimental analysis and numerical thermal simulations. For this device, the positive temperature coefficient of the draingate leakage current can lead to the formation of hot spots. This localized thermal runaway which ultimately results in a breakdown of the inherent drain-gate junction is found to be the dominant cause of failure.
This paper presents an efficient implementation of a reconfigurable battery stack which allows full exploitation of the capacity of every single cell. Contrary to most other approaches, it is possible to electrically remove one or more cells from the battery stack. Therefore, the overall capacity of the system is not restricted by the weaker cells, and cells with very different states of health can be used, making the system very attractive for refurbished batteries. For the required switches, low-voltage high-current MOSFETs are used. A demonstrator has been built with a total capacity of up to 3.5 kWh, a nominal voltage of 35 V, and currents up 200 A.