DMOS transistors are often subject to high power dissipation and thus substantial self-heating. This limits their safe operating area because very high device temperatures can lead to thermal runaway and subsequent destruction. Because the peak temperature usually occurs only in a small region in the device, it is possible to redistribute part of the dissipated power from the hot region to the cooler device areas. In this way, the peak temperature is reduced, whereas the total power dissipation is still the same. Assuming that a certain temperature must not be exceeded for safe operation, the improved device is now capable of withstanding higher amounts of energy with an unchanged device area. This paper presents two simple methods to redistribute the power dissipation density and thus lower the peak device temperature. The presented methods only require layout changes. They can easily be applied to modern power technologies without the need of process modifications. Both methods are implemented in test structures and investigated by simulations and measurements.
DMOS transistors often suffer from substantial self-heating during high power dissipation, which can lead to thermal destruction if the device temperature reaches excessive values. A successfully demonstrated method to reduce the peak temperature is the redistribution of power dissipation density from the hotter to the cooler device areas by careful layout modification. However, this is very tedious and time-consuming if complex-shaped devices as often found in industrial applications are considered.
This paper presents an approach for fully automatic layout optimization which requires only a few hours processing time. The approach is applied to complex shaped test structures which are investigated by measurements and electro-thermal simulations. Results show a significantly lower peak temperature and an energy capability gain of 84 %, offering potential for a 18 % size reduction of active area.
We present a compact battery charger topology for weight and cost sensitive applications with an average output current of 9A targeted for 36V batteries commonly found in electric bicycles. Instead of using a conventional boost converter with large DC-link capacitors, we accomplish PFC-functionality by shaping the charging current into a sin²-shape. In addition, a novel control scheme without input-current sensing is introduced. A-priori knowledge is used to implement a feed-forward control in combination with a closed-loop output current control to maintain the target current. The use of a full-bridge/half bridge LLC converter enables operation in a wide input-voltage range.
A fully featured prototype has been built with a peak output power of 1050W. An average output power of 400W was measured, resulting in a power density of 1.8 kW/dm³. At 9A charging current, a power factor of 0.96 was measured and the efficiency exceeds 93% on average with passive rectification.
The impact of pulse charging has been evaluated on a 400Wh battery which was charged with the proposed converter as well as CC-CV-charging for reference. Both charging schemes show similar battery surface temperatures.
The Dual Active Bridge (DAB) is a very promising topology for future power converters. However, careless operation can lead to a DC component in the transformer current. The problem is further exacerbated when the phase shift changes during operation. This work presents a study of DC bias effects on the DAB with special regard to transient effects introduced by sudden shifts in the output load. We present a simple yet effective approach to avoid DC bias entirely.
A novel configuration of the dual active bridge (DAB) DC/DC converter is presented, enabling more efficient wide voltage range conversion at light loads. A third phase leg as well as a center tapped transformer are introduced to one side of the converter. This concept provides two different turn ratios, thus extending the zero voltage switching operation resulting in higher efficiency. A laboratory prototype was built converting an input voltage of 40V to an output voltage in the range of 350V to 650V. Measurements show a significant increase up to 20% in the efficiency for light-load operation.
This paper presents a control strategy for optimal utilization of photovoltaic (PV) generated power in conjunction with an Energy Storage System (ESS). The ESS is specifically designed to be retrofitted into existing PV systems in an end-user application. It can be attached in parallel to the PV system and connects to existing DC/AC inverters. In particular, the study covers the impact such a modification has on the output power of existing PV panels. A distinct degradation of PV output power was found due to the different power characteristics of PV panel and ESS. To overcome such degradation a novel feedback system is proposed. The feedback system continuously modifies the power characteristic of the ESS to match the PV panel and thus achieves optimal power utilization. Impact on PV and power point tracking performance is analyzed. Simulation of the proposed system is performed in MATLAB/Simulink. The results are found to be satisfactory.
We present a dual active bridge topology suitable for wide voltage range applications covering all combinations of 200V to 600V on the input and 20V to 60V on the output with constant power of 1kW.We employ a stepped inductance scheme to adjust the effective inductance of the converter, thus extending the efficient operation range. Using a variable switching frequency between 35 kHz and 150 kHz with operation-point-dependent limits further increases the performance of the converter. A prototype was built and the proposed changes have been compared to a fixed frequency, fixed inductance implementation. Measurements show a maximum loss reduction of 40 %, leading to a peak efficiency of 97% while maintaining constant output power over the entire working area.
This paper presents an efficient implementation of a reconfigurable battery stack which allows full exploitation of the capacity of every single cell. Contrary to most other approaches, it is possible to electrically remove one or more cells from the battery stack. Therefore, the overall capacity of the system is not restricted by the weaker cells, and cells with very different states of health can be used, making the system very attractive for refurbished batteries. For the required switches, low-voltage high-current MOSFETs are used. A demonstrator has been built with a total capacity of up to 3.5 kWh, a nominal voltage of 35 V, and currents up 200 A.
The superior electrical and thermal properties of silicon carbide (SiC) allow further shrinking of the active area of future power semiconductor devices. A lower boundary of the die size can be obtained from the thermal impedance required to withstand the high power dissipation during a short-circuit event. However, this implies that the power distribution is homogeneous and that no current filamentation has to be considered. Therefore, this work investigates this assumption by evaluating the stability of a SiC-MOSFET over a wide range of operation conditions by measurements up to destruction, thermal simulations, and high-temperature characterization.