Methods for increasing the energy efficiency of induction motors by an appropriate control strategy have been a subject of research during the last years. Several methods for loss minimization have been developed for induction motors operated in a steady state. In recent years, some solutions for the dynamic case have been given as well either using an online or offline optimization approach, implying a certain computational burden, which is undesired in practice. This paper shows that the appropriate application of steady state techniques during transients due to a changing motor torque is a suboptimal strategy with an acceptable performance for efficiency optimization given an induction machine where saturation effects of the main inductance must be considered. The optimization problem is simplified such that a simple suboptimal solution is possible and the quality of the suboptimal solution is investigated by simulations and measurements. The proposed solution is simple, easy to implement, and does not require an online optimization. In addition, the influence of magnetizing induction saturation is considered.
In this article feedback linearization for control-affine nonlinear systems is extended to systems where linearization is not feasible in the complete state space by combining state feedback linearization and homotopy numerical continuation in subspaces of the phase space where feedback linearization fails. Starting from the conceptual simplicity of feedback linearization, this new method expands the scope of their applicability to irregular systems with poorly expressed relative degree. The method is illustrated on a simple SISO–system and by controlling the speed and the rotor flux linkage in a three phase induction machine.
Modern wide bandgap power devices promise higher power conversion performance if the device can be operated reliably. As switching speed increases, the effects of parasitic ringing become more prominent, causing potentially damaging overvoltages during device turn-off. Estimating the expected additional voltage caused by such ringing enables more reliable designs. In this paper, we present an analytical expression to calculate the expected overvoltage caused by parasitic ringing based on parasitic element values and operating point parameters. Simulations and measurements confirm that the expression can be used to find the smallest rise time of the switches’ drain-source voltage for minimum overvoltage. The given expression also allows the prediction of the trade off overvoltage amplitude in case of faster required rise times.
The current paper discusses the optimal choice of a filter time constant for filtering the steady state flux reference in an energy efficient control strategy for changing load torques. It is shown that by appropriately choosing the filter time constant as a fraction of the rotor time constant the instantaneous power losses after a load torque step can be significantly reduced compared to the standard case. The analysis for the appropriate choice of the filter time constant is based on a numerical study for three different induction motors with different rated powers.
Purpose. To improve the efficiency of the closed-cycle operation of the field-orientation induction machine in dynamic behavior when load conditions are changing, considering the nonlinearities of the main inductance.
Methodology. The optimal control problem is defined as the minimization of the time integral of the energy losses. The algorithm observed in this paper uses the Matlab/Simulink, dSPACE real-time interface, and C language. Handling real-time applications is made in ControlDesk experiment software for seamless ECU development.
Findings. Adiscrete-time model with an integrated predictive control scheme where the optimization is performed online at every sampling step has been developed. The optimal field-producing current trajectory is determined, so that the copper losses are minimized over a wide operational range. Additionally, the comparison of measurement results with conventional methods is provided, which validates the advantages and performance of the control scheme.
Originality. To solve the given problem, the information vector on the current state of the coordinates of the electromechanical system is used to form a controlling influence in the dynamic mode of operation. For the first time, the formation process of controls has considered the current state and the desired future state of the system in the real-time domain.
Practical value. Apredictive iterative approach for optimal flux level of an induction machine is important to generate the required electromagnetic torque and to reduce power losses simultaneously.
Steady state efficiency optimization techniques for induction motors are state of the art and various methods have already been developed. This paper provides new insights in the efficiency optimized operation in dynamic regime. The paper proposes an anticipative flux modification in order to decrease losses during torque and speed transients. These trajectories are analyzed based on a numerical study for different motors. Measurement results for one motor are given as well.
Energy efficient electric control of drives is more and more important for electric mobility and manufacturing industries. Online dynamic optimization of induction machines is challenging due to the computational complexity involved and the variable power losses during dynamic operation of induction machines. This paper proposes a simple technique for sub-optimal online loss optimization using rotor flux linkage templates for energy efficient dynamic operation of induction machines. Such a rotor flux linkage template is given by a rotor flux linkage trajectory which is optimal for a specific scenario. This template is calculated in an offline optimization process. For a specific scenario during real time operation the rotor flux linkage is calculated by appropriately scaling the given template.
Energy efficiency optimization techniques for steady state operation of induction machines are the state-of-the-art, and many methods have already been developed. However, many real-world industrial and electric vehicle applications cannot be considered to be in steady state operation. The focus of this contribution is on the efficiency optimization of induction machines in dynamic operation. Online dynamic operation is challenging due to the computational complexity and the required low sample times in an inverter. An offline optimization is therefore conducted to gain knowledge. Based on this offline optimal solution, a simple and easy to implement template based solution is developed. This approach aims at replicating the solution found by the offline optimization by resembling the shape and anticipative characteristics of the optimal flux trajectory. The energy efficiency improvement of the template based solution is verified by simulations and measurements on a test bench and using a real-world drive cycle scenario. For comparison, a model predictive numerical online optimization is investigated too.
This paper discusses the optimal control problem for increasing the energy efficiency of induction machines in dynamic operation including field weakening regime. In an offline procedure optimal current and flux trajectories are determined such that the copper losses are minimized during transient operations. These trajectories are useful for a subsequent online implementation.
Class Phi2 amplifier using GaN HEMTs at 13.56MHz with tuned transformer for wireless power transfer
(2022)
This paper discusses a design procedure of a wireless power transfer system at a RF switching frequency of 13.56MHz. The wireless power transfer amplifier uses GaN HEMTs in aClass phi2 topology and is designed in order to achieve high efficiency and high power density. A design method for the load over a certain bandwidth is presented for a transformer with its tuning network.