Refine
Year of publication
Document Type
Is part of the Bibliography
- yes (43)
Institute
- Technik (43)
Publisher
- IEEE (21)
- VDE Verlag GmbH (6)
- Apprimus Wissenschaftsverlag (2)
- Academic Publications Ltd. (1)
- British Institute of Non-Destructive Testing (1)
- De Gruyter Open (1)
- GRID-FTN (1)
- Hochschule für Technik, Wirtschaft und Kultur Leipzig (1)
- Hochschulen für Angewandte Wissenschaften Baden-Württemberg, Koordinierungsstelle (1)
- MDPI (1)
This paper presents an approach for the implementation of a modular and scalable power electronics device for controlling electric drives in the field of electric vehicles using wide bandgap semiconductor devices. The main idea is to achieve the required output currents or voltages by connecting adequately designed hardware modules in parallel or in series. This particular design is based on the fact that the single modules generate a continuous and specified output voltage from a given dc voltage, e.g. an intermediate circuit or battery voltage. The main benefit is, that different current or voltage requirements can be satisfied based on a single module thus decreasing development and production costs. The current paper focuses on the connection in parallel of such modules. A control architecture is illustrated and a first proof of concept is given.
A novel brushless excitation concept for synchronous machines with a rotating power converter is proposed in this paper. The concept does not need an auxiliary winding or any other modification to the machine structure apart from an inverter with a DC link capacitor and a controller on the rotor. The power required for the rotor excitation is provided by injecting harmonics into the stator winding. Thus, a voltage in the field coil is induced. The rotor inverter is controlled such that the alternating current charges the DC link capacitor. At the same time the inverter supplies the DC field current to the field coil. The excitation concept is first developed in theory, then presented using an analytical model and FEA, and lastly investigated with a prelimininary experimental setup.
A simple determination of the error voltage compensation map for motor parameter identification
(2018)
This paper proposes a new method for determining the error voltage compensation map in a parameter identification procedure of three-phase induction motors with an inverter. The compensation curve depending on the motor current is determined using a simple procedure based on given reference voltage steps and the corresponding steady state values of the stator current of the induction motor.
This paper illustrates the implementation of series connected hardware modules as part of a scalable and modular power electronics device, which is ideally suited in the field of electric vehicles using wide bandgap semiconductor devices. The main benefit of the modular concept is that different current or voltage requirements can be satisfied based on the appropriate series or parallel connection of single modules. The particular design is based on the fact that the single modules generate a continuous and specified output voltage from a given dc voltage. The current work focuses on a brief classification of this work in different series connected concepts of power converters and in particular on an active damping approach for the series connected LC output filters based on inductor current feedback.
This paper presents a modular and scalable power electronics concept for motor control with continuous output voltage. In contrast to multilevel concepts, modules with continuous output voltage are connected in series. The continuous output voltage of each module is obtained by using gallium nitride (GaN) high electron motility transistor (HEMT)s as switches inside the modules with a switching frequency in the range between 500 kHz and 1 MHz. Due to this high switching frequency a LC filter is integrated into the module resulting in a continuous output voltage. A main topic of the paper is the active damping of this LC output filter for each module and the analysis of the series connection of the damping behaviour. The results are illustrated with simulations and measurements.
This contribution presents a three-phase power stage for motor control with continuous output voltages using wide bandgap semiconductors and an asynchronous delta-sigma based switching signal generation. The focus of the paper is on an active damping approach for the LC output filter based on inductor current feedback.
This paper presents a laboratory experiment integrating the fields of electronics design, power electronics and drive control. The aim of this experiment is first to illustrate the need for a deep knowledge and the challenges in power electronics and its applications, in this particular case for drive control. The different tasks in this experiment are executed on a complete setup for a brushless dc motor test bench. The tasks assigned to the students are designed such that, in some tasks the knowledge from a particular field, power electronics, electronic design or drive control is deepened, whereas in other tasks the knowledge from more than one of these fields is needed to solve the given problem. Thus, the experiment trains students in the particular domains but illustrates as well the links between power electronics, electronic design and drive control.
In diesem Beitrag wurde gezeigt, wie mit Hilfe von Verfahren zur Analyse von Petri–Netzen ein in der Programmiersprache Kontaktplan erstelltes SPS–Programm analysiert werden kann. Das Ziel des Verfahrens ist dabei nicht eine Verifikation im eigentlichen Sinne sondern das Aufdecken von verbotenen oder unerwünschten Zuständen. Im Beitrag wurden Regeln zur Transformation des im Kontaktplan erstellten Ablaufs in ein Petri–Netz angegeben und anhand der Analyse eines fehlerhaft implementierten Ablaufs die Leistungsfähigkeit des Ansatzes vorgestellt. Das Beispiel zeigt, dass Programmfehler bereits vor einem Test an der realen Anlage erkannt werden können. Bei der weiteren Entwicklung des Verfahrens liegt ein Schwerpunkt auf der Verallgemeinerung auf im Kontaktplan entwickelte Programmorganisationseinheiten, die nicht nur reine
Abläufe implementieren. Ein weiterer wichtiger Entwicklungsschritt ist die graphische Unterstützung der Fehlersuche im Erreichbarkeitsgraphen, so dass insgesamt ein leistungsfähiges Werkzeug zur Unterstützung der Implementierung von Ablaufsteuerungen im Kontaktplan zur Verfügung steht.
Modern wide bandgap power devices promise higher power conversion performance if the device can be operated reliably. As switching speed increases, the effects of parasitic ringing become more prominent, causing potentially damaging overvoltages during device turn-off. Estimating the expected additional voltage caused by such ringing enables more reliable designs. In this paper, we present an analytical expression to calculate the expected overvoltage caused by parasitic ringing based on parasitic element values and operating point parameters. Simulations and measurements confirm that the expression can be used to find the smallest rise time of the switches’ drain-source voltage for minimum overvoltage. The given expression also allows the prediction of the trade off overvoltage amplitude in case of faster required rise times.