Refine
Document Type
- Journal article (7)
Language
- English (7)
Has full text
- yes (7)
Is part of the Bibliography
- yes (7)
Institute
- Life Sciences (7)
Publisher
- De Gruyter (3)
- American Chemical Society (1)
- Elsevier (1)
- Frontiers (1)
- MDPI (1)
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.
Adapting characteristics of biomaterials specifically for in vitro and in vivo applications is becoming increasingly important in order to control interactions between material and biological systems. These complex interactions are influenced by surface properties like chemical composition, charge, mechanical and topographic attributes. In many cases it is not useful or even not possible to alter the base material but changing surface, to improve biocompatibility or to make surfaces bioactive, may be achieved by thin coatings. An already established method is the coating with polyelectrolyte multilayers (PEM). To adjust adhesion, proliferation and improve vitality of certain cell types, we modified the roughness of PEM coatings. We included different types nanoparticles (NP’s) in different concentrations into PEM coatings for controlling surface roughness. Surface properties were characterized and the reaction of 3 different cell types on these coatings was tested.
Polyelectrolyte multilayer coatings (PEM) are prepared by alternative layer-by-layer deposition of cationic and anionic polyelectrolyte monolayers on charged surfaces. The thickness of the coatings ranges from nm to few μm. Their properties such as roughness, stiffness, surface charge and surface energy can be precisely tuned to fulfil different technical or biological requirements. The coating process is based on self-assembly of polyelectrolytes. Advantages of these coatings are their easy handling, no harsh chemistry and the possibility for coatings on complex geometries. The PEM coatings can be prepared from a variety of suitable polyelectrolytes. Their stability varies from very durable PEM coatings that are only soluble in strong solvents to quickly degradable, which may be applied as drug release system. One example of such a degradable PEM system is the one based on the polyelectrolyte pair Hyaluronan (HA) and Chitosan (CHI). These biopolymers originate from natural sources and show low toxicity towards human cells. However, HA/CHI multilayers show only weak adhesiveness for human umbilical vein endothelial cells (HUVEC). In this article, we summarize our approaches to enhance the HA/CHI multilayer by incorporation of a non-polymer substance –graphene oxide– to improve the cell adhesion and keep such properties as low cytotoxicity and biodegradability. Different approaches for incorporation of graphene oxide were performed and the cellular adhesion was tested by metabolic assay.
Controlled adhesion of HUVEC on polyelectrolyte multilayers by regulation of coating conditions
(2021)
Adhesion of host cells on the surface of implants is necessary for a healthy ingrowth of the implanted material. One possibility of surface modification is the coating of the implant with a second material with advantageous physical–chemical surface properties for the biological system. The coverage with blood proteins takes place immediately after implantation. It is followed by host–cell interaction on the surface. In this work, the effect of polyelectrolyte multilayer coatings (PEMs) on adhesion and activity of human umbilical vein endothelial cells (HUVECs) was studied. The PEMs were formed from poly(styrenesulfonate) (PSS) and poly(allylamine hydrochloride) (PAH) from solutions with different concentrations of NaCl varying between 0 and 1.0 M. The adhesion of HUVEC and their viability on the PEM is related to the amount of adsorbed proteins from the applied cell growth medium. The amount of adsorbed proteins is controlled not only by the surface charge but also by the internal excess charge of the PEM. The internal excess charge of the PEM was controlled by changing the electrolyte concentration in the deposition solutions.
Composite polymer/wax coatings as a corrosion barrier of bioresorbable magnesium coronary stents
(2024)
Magnesium and its alloys are suitable materials for biodegradable biomedical implants such as cardiovascular stents. Here we introduce an innovative composite polyelectrolyte multilayer/wax coating applied to commercial coronary Mg-based stents serving as a barrier layer effectively retarding corrosion. This hydrophobic coating, build by layer-by-layer technology, appeared very thin, smooth, homogeneous, strongly adherent and completely covering the surface of the Mg-stent. In-vitro degradation tests showed greater resistance to degradation of coated Mg-stents compared to uncoated and passivated ones. Cytocompatibility studies proved that Mg-stent coated with the composite coating was non-cytotoxic and improved fibroblast cell viability compared to the uncoated Mg-stent.
Bioactive cations, including calcium, copper and magnesium, have shown the potential to become the alternative to protein growth factor-based therapeutics for bone healing. Ion substitutions are less costly, more stable, and more effective at low concentrations. Although they have been shown to be effective in providing bone grafts with more biological functions, the precise control of ion release kinetics is still a challenge. Moreover, the synergistic effect of three or more metal ions on bone regeneration has rarely been studied. In this study, vaterite-calcite CaCO3 particles were loaded with copper (Cu2+) and magnesium (Mg2+). The polyelectrolyte multilayer (PEM) was deposited on CaCuMg-CO3 particles via layer-by-layer technique to further improve the stability and biocompatibility of the particles and to enable controlled release of multiple metal ions. The PEM coated microcapsules were successfully combined with collagen at the outmost layer, providing a further stimulating microenvironment for bone regeneration. The in vitro release studies showed remarkably stable release of Cu2+ in 2 months without initial burst release. Mg2+ was released in relatively low concentration in the first 7 days. Cell culture studies showed that CaCuMg-PEM-Col microcapsules stimulated cell proliferation, extracellular maturation and mineralization more effectively than blank control and other microcapsules without collagen adsorption (Ca-PEM, CaCu-PEM, CaMg-PEM, CaCuMg-PEM). In addition, the CaCuMg-PEM-Col microcapsules showed positive effects on osteogenesis and angiogenesis in gene expression studies. The results indicate that such a functional and controllable delivery system of multiple bioactive ions might be a safer, simpler and more efficient alternative of protein growth factor-based therapeutics for bone regeneration. It also provides an effective method for functionalizing bone grafts for bone tissue engineering.
Controlling cell adhesion, viability, and proliferation on solid surfaces is critical for the successful implantation and proper functioning of temporary and permanent medical devices. While, with temporary or removable implants as well as surgical instruments, even slight cellular adhesion leads to an increased risk of secondary infections, bleeding and other complications, good cellular adhesion and viability are essential for the rapid healing and successful integration of permanent implants. This work was motivated by the growing interest in the construction of biocompatible and biodegradable coatings for the biofunctionalization of medical devices. Polysaccharide-based coatings are well known for their biocompatibility, but they are non-cell-adhesive, which hinders their application as implant coatings. In this study, we demonstrate that the incorporation of one or more graphene oxide layers in hyaluronic acid/chitosan multilayers is one avenue to regulate the degree of unspecific adhesion and growth of different cells (human umbilical vein endothelial cells, HUVEC, and mouse embryonic fibroblasts, 3T3). Furthermore, we demonstrate that this approach allows cell adhesion to be regulated across the entire range between completely prevented and highly promoted cell adhesion without introducing systemic cytotoxicity. These findings may contribute to the establishment of a new approach to adapt medical devices to cells and tissues.