The coupling of the heat and power sector is required as supply and demand in the German electricity mix drift further and further apart with a high percentage of renewable energy. Heat pumps in combination with thermal energy storage systems can be a useful way to couple the heat and power sectors. This paper presents a hardware-in the-loop test bench for experimental investigation of optimized control strategies for heat pumps. 24-hour experiments are carried out to test whether the heat pump is able to serve optimized schedules generated by a MATLAB algorithm. The results show that the heat pump is capable of following the generated schedules, and the maximum deviation of the operational time between schedule and experiment is only 3%. Additionally, the system can serve the demand for space heating and DHW at any time.
Bis zum Jahr 2050 soll in Baden Württemberg mit dem Ziel „50-80-90“ der Energiebedarf um 50% reduziert werden, die erneuerbaren Energien sollen zu 80% an der Energieversorgung beteiligt sein und die Emissionen von Treibhausgasen um 90% sinken.Entsprechende Ziele sind für andere Regionen und Länder in ähnlicher Weise festgelegt.
Damit diese Ziele erreicht werden, muss bei der Gebäudewärmeversorgung ein konsequenter Umbau stattfinden. Hier spielt die Sektorenkopplung mit Hilfe von Wärmepumpen (WP) eine entscheidende Rolle. Zur Abschätzung des Potenzials sowie des Aufwandes für einen großflächigen Einsatz von Wärmepumpen ist es unmöglich, eine spezifische und angepasste Dimensionierung der Wärmepumpensysteme für jedes einzelne Gebäude durchzuführen. Stattdessen müssen auf Seiten der Bebauung Referenzgebäude definiert und auf Seiten der Wärmepumpensysteme mittlere Leistungsdaten der am Markt befindlichen Modelle verwendet werden. Während die Festlegung von Referenzgebäuden verschiedentlich in der Literatur zu finden ist, widmet sich der erste Teil der Veröffentlichung der Vorstellung von Korrelationsfunktionen für die thermische und elektrische Leistung sowie die Leistungszahl (COP) von Wärmepumpen, die auf Basis von Herstellerdaten in Abhängigkeit der Quellen- und Vorlauftemperatur ermittelt wurden.
Konkret wurden als Ausgangsbasis für die Korrelationsfunktionen Datenblätter verschiedener Sole- und Luft-Wasser Wärmepumpen (SWP, LWP) zusammengestellt und ausgewertet. Die Grundlage hierfür war die Liste „Wärmepumpen mit Prüfnachweis eines unabhängigen Prüfinstituts“ des Bundesamts für Wirtschaft und Ausfuhrkontrolle (BAFA).
The integration of renewable energy sources in single family homes is challenging. Advance knowledge of the demand of electrical energy, heat, and domestic hot water (DHW) is useful to schedule projectable devices like heat pumps. In this work, we consider demand time series for heat and DHW from 2018 for a single family home in Germany. We compare different forecasting methods to predict such demands for the next day. While the 1-day-back forecast method led to the prediction of heat demand, the N-day-average performed best for DHW demand when Unbiased Exponentially Moving Average (UEMA) is used with a memory of 2.5 days. This is surprising as these forecasting methods are very simple and do not leverage additional information sources such as weather forecasts.
The main challenge when driving heat pumps by PV-electricity is balancing differing electrical and thermal demands. In this article, a heuristic method for optimal operation of a heat pump driven by a maximum share of PV-electricity is presented. For this purpose, the (DHW) are activated in order shift the operation of the heat pump to times of PV-generation. The system under consideration refers to thermal and electrical demands of a single family house. It consists of a heat pump, a thermal energy storage for DHW and of grid connected heating and generation of domestic hot water, the heat pump runs with two different supply temperatures and thereby achieving a maximum overall COP. Within the algorithm for optimization a set of heuristic rules is developed in a way that the operational characteristics of the heat pump in terms of minimum running and stopping times are met as well as the limiting constraints of upper and lower limits of room temperature and energy content of electricity generated, a varying number of heat pump schedules fulfilling the bundary conditions are created. Finally, the schedule offering the maximum on-site utilization of PV-electricity with a minimum number of starts of the heat pump, which serves as secondary condition, is selected. Yearly simulations of this combination have been carried out. Initial results of this method indicate a significant rise in on-site consumption of the PV-electricity and heating demand fulfilment by renewable electricity with no need for a massive TES for the heating system in terms of a big water tank.
Ein wirtschaftlicher Betrieb von KWK-Anlagen ist erreichbar, wenn Geräte mit gutem elektrischen Wirkungsgrad und geringen Anschaffungs- und Wartungskosten eingesetzt werden und der im BHKW erzeugte Strom zum größtmöglichen Anteil im Objekt verbraucht wird. Der Pufferspeicher einer KWK-Anlage sollte ausreichend groß bemessen sein (Flexibilität, Eigenstromoptimierung...). Ein größeres BHKW ist nicht automatisch unwirtschaftlicher aufgrund der geringeren Betriebszeit. Es bietet dagegen ein höheres Potenzial für eine bedarfsgerechte Stromeinspeisung in das Netz.
Die Wirkungsgrade ("Normnutzungsgrade") nach DIN 4709 bilden den praktischen Betrieb von Mikro-Blockheizkraftwerken besser ab. Insbesondere bei den thermischen Wirkungsgraden ergeben sich nach DIN 4709 geringere Werte im Vergleich zu stationären Messungen aufgrund der An-/Abfahrverluste und der Speicherverluste. Der Betrieb des Zusatzkessels führt zu einer Reduktion der Primärenergieeinsparung der Gesamtanlage.
The objective of the project presented here is to develop an intelligent control algorithm for an energy system consisting of a biogas CHP (combined heat and power), various storage technologies, such as thermal energy storages (TES) and gas storages, and other renewable energy sources, such as photovoltaics. A corresponding algorithm based on the Monte-Carlo method has already been developed at Reutlingen University for CHP units running on natural gas and for heat pumps. The project presented here concentrates on the further development of this algorithm for application to biogas CP units. In this context, an adequate implementation of the gas storage is of primary importance, as it mainly determines the flexibility of the plant. In the course of the validation of the new optimization algorithm, simulations were carried out based on data from the Lower Lindenhof, an agricultural experimental station of the University of Hohenheim. Both an optimization with regard to onsite electricity utilization and an optimization driven by residual load were investigated. Preliminary results show that the optimization algorithm can improve the operation of the biogas CHP unit depending on the selected target function.
This paper examines the deployment of Power to-X technologies in the US energy system through 2040. For this analysis, Power-to-X technologies have been added to an input database representing the US energy system as a single region, which is used in conjunction with an energy system optimization model called Tools for energy model optimization and analysis (Temoa). Detailed data for each individual technology, including water electrolysis, hydrogen compression and storage, chemical processing to synthetic natural gas (SNG) and methanol was collected and entered to the input database. Under a deep decarbonization scenario, Power-to-X is deployed beginning in 2035 under the assumption of no new nuclear power plants installed and a restriction on biodiesel production based on limited area for growing crops. The major portion of the hydrogen generated by electrolysis from excess PV- and wind-generated electricity goes into the production of methanol. This result suggests that Power-to-X is used to generate transport fuels in order to reduce CO2 emissions especially in this sector.
Dieser Bericht fasst die wesentlichen Arbeiten und Ergebnisse zusammen, die in dem Verbundvorhaben „GalvanoFlex_BW“ im Kalenderjahr 2018 durchgeführt und erzielt wurden. Dazu lässt sich zunächst sagen, dass die Messwertaufnahme und –auswertung abgeschlossen ist. Es wurden verschiedene Messkampagnen bei der Fa. NovoPlan durchgeführt. Bei C&C Bark konnte man teilweise auf bestehende Daten zurückgreifen, die punktuell durch weitere Messungen ergänzt wurden. Bei der Fa. Hartchrom konnten aufgrund von Personalmangel keine Messungen durchgeführt werden. Die aufgenommenen Daten wurden in eine Effizienzbewertung überführt, aus der im Folgenden allgemeine Aussagen abgeleitet werden sollen. Dazu ist ein Simulationsprogramm aufgesetzt worden, das in der Lage ist, Prozessketten energetisch abzubilden und zu optimieren. Zudem sollen aus den Messdaten verbesserte Profile für den Wärmebedarf in den Unternehmen entwickelt werden, die daraufhin der KWK-Optimierung zur Verfügung gestellt werden. Im Zuge der Entwicklung und Bewertung stromoptimierter KWK- Strategien ist ein bestehendes Simulationsmodell entsprechend weiterentwickelt worden. Konkret wurde das Modell um eine verbesserte Lastprognose für Strom und Wärme für Industriebetriebe ergänzt, und das Optimierungsverfahren wurde um eine zweite Dimension erweitert. Während bislang allein die Optimierung der Eigenstromdeckung mit einer Begrenzung der BHKW-Starts als Nebenbedingung möglich war, ist jetzt die Kappung der elektrischen Lastspitze zusätzlich in der Zielfunktion integriert. Gerade bei Industrieunternehmen lässt sich auf diese Weise eine weitere, zum Teil nicht unerhebliche Energiekosteneinsparung erreichen, was durch die ersten Berechnungen anhand der drei im Reallabor vertretenden Betriebe bestätigt wird. Die Ergebnisse werden unter AP 8 (Umsetzung) diskutiert. Der Dialog mit weiteren Unternehmen und Institutionen außerhalb des Vorhabens konnte über die Branchenplattfom weitergeführt werden. In 2018 wurden zwei Veranstaltungen dieser Art durchgeführt, und im Frühjahr 2019 wird ein weiterer Workshop zu diesem Thema durchgeführt. Die sozialwissenschaftliche Begleitforschung wurde mit der zweiten Phase der Firmenbefragungen ebenfalls planmäßig weitergeführt. Mit Blick auf die Umsetzung eines BHKW-Konzeptes haben sich dabei zwei wichtige Punkte wie folgt gezeigt: Zum einen muss die umsetzende Firma eine gewisse „Energieeffizienz-Reife“ besitzen, die sich u.a. in der Erfahrung bei der Durchführung von Energieeffizienzmaßnahmen zeigt, da die Installation eines BHKWs eine äußerst komplexe Maßnahme darstellt. Zum anderen müssen andere unternehmensspezifische Kontextfaktoren hinzukommen, wie z.B. aus anderen Gründen durchzuführende bauliche Maßnahmen, so dass gewisse zeitliche Entscheidungsfenster entstehen, in denen die Umsetzung von KWK-Maßnahmen sinnvoll sind.
Micro grids often consist of energy generators, storages and consumers with controllers which are not prepared for their integration into communication networks for energy systems. In this paper it will be presented, how standards from the field of energy automation can be applied in such controllers. The data for communication interfaces can be structured according to the IEC 61850- or the VHPREADY standard. It is investigated which requirements must be supported to implement such data models within the controllers. For the transmission of the data we propose the OPC UA protocol, which supports extensive security measures and which is today available for nearly all modern types of controllers and computers.