This paper illustrates the implementation of series connected hardware modules as part of a scalable and modular power electronics device, which is ideally suited in the field of electric vehicles using wide bandgap semiconductor devices. The main benefit of the modular concept is that different current or voltage requirements can be satisfied based on the appropriate series or parallel connection of single modules. The particular design is based on the fact that the single modules generate a continuous and specified output voltage from a given dc voltage. The current work focuses on a brief classification of this work in different series connected concepts of power converters and in particular on an active damping approach for the series connected LC output filters based on inductor current feedback.
This contribution presents a three-phase power stage for motor control with continuous output voltages using wide bandgap semiconductors and an asynchronous delta-sigma based switching signal generation. The focus of the paper is on an active damping approach for the LC output filter based on inductor current feedback.
This paper presents a modular and scalable power electronics concept for motor control with continuous output voltage. In contrast to multilevel concepts, modules with continuous output voltage are connected in series. The continuous output voltage of each module is obtained by using gallium nitride (GaN) high electron motility transistor (HEMT)s as switches inside the modules with a switching frequency in the range between 500 kHz and 1 MHz. Due to this high switching frequency a LC filter is integrated into the module resulting in a continuous output voltage. A main topic of the paper is the active damping of this LC output filter for each module and the analysis of the series connection of the damping behaviour. The results are illustrated with simulations and measurements.
Switched reluctance motors are particularly attractive due to their simple structure. The control of this machine type requires the instants, to switch the currents in the motor phases in an appropriate sequence. These switching instants are determined either based on a position sensor, or on signals generated by a sensorless method. A very simple sensorless method uses the switching frequency of the hysteresis controllers used for phase current control. This paper first presents an automatic commissioning method for this sensorless method and second a startup procedure, thus enhancing this approach towards an application in industry.
This article illustrates a method for sensorless control of a switched reluctance motor. The detection of the time instants for switching between the working phases is determined based on the evaluation of the switching frequency of the hysteresis current controllers for appropriately selected sensing phases. This enables a simple and cost efficient implementation. The method is compared with a pulse injection method in terms of efficiency and resolution.
Simulation eines dezentralen Regelungssystems zur netzdienlichen Erzeugung von grünem Wasserstoff
(2023)
Wasserstoff wird einen bedeutenden Beitrag zum Wandel von Industrie und Gesellschaft in eine klimaneutrale Zukunft leisten. Der Aufbau und die ökologisch und ökonomisch sinnvolle Nutzung einer Wasserstoffinfrastruktur sind hierbei die zentralen Herausforderungen. Ein notwendiger Baustein ist die effiziente Bereitstellung von grünem Strom und dem daraus produzierten grünen Wasserstoff. Der vorliegende Beitrag stellt ein dezentrales Regel- und Kommunikationssystem vor, mit dem Angebot und Nachfrage von grünem Strom und Wasserstoff in einem System aus dezentralen Akteuren in Einklang gebracht werden. In einer hierzu entwickelten Simulationsumgebung wird die Funktion und der Nutzen dieses dezentralen Ansatzes verdeutlicht.
In this work, a comparison between different brushless harmonic-excited wound-rotor synchronous machines is performed. The general idea of all topologies is the elimination of the slip rings and auxiliary windings by using the already existing stator and rotor winding for field excitation. This is achieved by injecting a harmonic airgap field with the help of power electronics. This harmonic field does not interact with the fundamental field, it just transfers the excitation power across the airgap. Alternative methods with varying number of phases, different pole-pair combinations, and winding layouts are covered and compared with a detailed Finite-Element-parameterized model. Parasitic effects due to saturation and coupling between the harmonic and main windings are considered.