Refine
Document Type
- Journal article (31)
- Patent / Standard / Guidelines (3)
- Book chapter (2)
- Book (1)
- Conference proceeding (1)
- Working Paper (1)
Is part of the Bibliography
- yes (39)
Institute
- Life Sciences (38)
- Technik (1)
Publisher
- Springer (7)
- MDPI (6)
- Elsevier (5)
- Wiley (4)
- American Chemical Society (2)
- ACS (1)
- De Gruyter (1)
- Frontiers Media (1)
- Hanser (1)
- Hindawi (1)
Water jacket systems are routinely used to control the temperature of Petri dish cell culture chambers. Despite their widespread use, the thermal characteristics of such systems have not been fully investigated. In this study, we conducted a comprehensive set of theoretical, numerical and experimental analyses to investigate the thermal characteristics of Petri dish chambers under stable and transient conditions. In particular, we investigated the temperature gradient along the radial axis of the Petri dish under stable conditions, and the transition period under transient conditions. Our studies indicate a radial temperature gradient of 3.3 °C along with a transition period of 27.5 min when increasing the sample temperature from 37 to 45 °C for a standard 35 mm diameter Petri dish. We characterized the temperature gradient and transition period under various operational, geometric, and environmental conditions. Under stable conditions, reducing the diameter of the Petri dish and incorporating a heater underneath the Petri dish can effectively reduce the temperature gradient across the sample. In comparison, under transient conditions, reducing the diameter of the Petri dish, reducing sample volume, and using glass Petri dish chambers can reduce the transition period.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms S mit einem Einlassbereich E, einem Messbereich M und einen Auslassbereich A sowie mit einer ersten Weiche W1 und einer zweiten Weiche W2 und einem Umlenkbereich U, wobei die beiden Weichen W1, W2 in einem ersten Schaltzustand Z1 einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Messbereich M über die zweite Weiche W2 bis zum Auslassbereich A ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Umkenkbereich U über die zweite Weiche W2 bis zum Auslassbereich A ausbilden.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms (S) mit einem Einlassbereich (E), einem Messbereich (M) und einen Auslassbereich (A) sowie mit einer ersten Weiche (W1) und einer zweiten Weiche (W2) und einem Umlenkbereich (U), wobei die beiden Weichen (W1, W2) in einem ersten Schaltzustand (Z1) einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Messbereich (M) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Umlenkbereich (U) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden.
Hyperspectral imaging and reflectance spectroscopy in the range from 200–380 nm were used to rapidly detect and characterize copper oxidation states and their layer thicknesses on direct bonded copper in a non-destructive way. Single-point UV reflectance spectroscopy, as a well-established method, was utilized to compare the quality of the hyperspectral imaging results. For the laterally resolved measurements of the copper surfaces an UV hyperspectral imaging setup based on a pushbroom imager was used. Six different types of direct bonded copper were studied. Each type had a different oxide layer thickness and was analyzed by depth profiling using X-ray photoelectron spectroscopy. In total, 28 samples were measured to develop multivariate models to characterize and predict the oxide layer thicknesses. The principal component analysis models (PCA) enabled a general differentiation between the sample types on the first two PCs with 100.0% and 96% explained variance for UV spectroscopy and hyperspectral imaging, respectively. Partial least squares regression (PLS-R) models showed reliable performance with R2c = 0.94 and 0.94 and RMSEC = 1.64 nm and 1.76 nm, respectively. The developed in-line prototype system combined with multivariate data modeling shows high potential for further development of this technique towards real large-scale processes.
To correctly assess the cleanliness of technical surfaces in a production process, corresponding online monitoring systems must provide sufficient data. A promising method for fast, large-area, and non-contact monitoring is hyperspectral imaging (HSI), which was used in this paper for the detection and quantification of organic surface contaminations. Depending on the cleaning parameter constellation, different levels of organic residues remained on the surface. Afterwards, the cleanliness was determined by the carbon content in the atom percent on the sample surfaces, characterized by XPS and AES. The HSI data and the XPS measurements were correlated, using machine learning methods, to generate a predictive model for the carbon content of the surface. The regression algorithms elastic net, random forest regression, and support vector machine regression were used. Overall, the developed method was able to quantify organic contaminations on technical surfaces. The best regression model found was a random forest model, which achieved an R2 of 0.7 and an RMSE of 7.65 At.-% C. Due to the easy-to-use measurement and the fast evaluation by machine learning, the method seems suitable for an online monitoring system. However, the results also show that further experiments are necessary to improve the quality of the prediction models.
Titanium(IV) surface complexes bearing chelating catecholato ligands for enhanced band-gap reduction
(2023)
Protonolysis reactions between dimethylamido titanium(IV) catecholate [Ti(CAT)(NMe2)2]2 and neopentanol or tris(tert-butoxy)silanol gave catecholato-bridged dimers [(Ti(CAT)(OCH2tBu)2)(HNMe2)]2 and [Ti(CAT){OSi(OtBu)3}2(HNMe2)2]2, respectively. Analogous reactions using the dimeric dimethylamido titanium(IV) (3,6-di-tert-butyl)catecholate [Ti(CATtBu2-3,6)(NMe2)2]2 yielded the monomeric Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2 and Ti(CATtBu2-3,6)[OSi(OtBu)3]2(HNMe2)2. The neopentoxide complex Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2 engaged in further protonolysis reactions with Si–OH groups and was consequentially used for grafting onto mesoporous silica KIT-6. Upon immobilization, the surface complex [Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2]@[KIT-6] retained the bidentate chelating geometry of the catecholato ligand. This convergent grafting strategy was compared with a sequential and an aqueous approach, which gave either a mixture of bidentate chelating species with a bipodally anchored Ti(IV) center along with other physisorbed surface species or not clearly identifiable surface species. Extension of the convergent and aqueous approaches to anatase mesoporous titania (m-TiO2) enabled optical and electronic investigations of the corresponding surface species, revealing that the band-gap reduction is more pronounced for the bidentate chelating species (convergent approach) than for that obtained via the aqueous approach. The applied methods include X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and solid-state UV/vis spectroscopy. The energy-level alignment for the surface species from the aqueous approach, calculated from experimental data, accounts for the well-known type II excitation mechanism, whereas the findings indicate a distinct excitation mechanism for the bidentate chelating surface species of the material [Ti(CATtBu2-3,6)(OCH2tBu)2(HNMe2)2]@[m-TiO2].
Derzeit finden gravierende Veränderungen im Umfeld der Informations- und Kommunikationstechnik statt, die eine große Chance für die optimierte Prozessführung und Wertschöpfung mit darauf abgestimmten vernetzt kommunizierenden Sensoren bieten. Diese Art "smarter" Sensoren stellen Dienste innerhalb eines Netzwerks bereit und nutzen Informationen daraus. Dadurch ergibt sich aktuell die Notwendigkeit, die Anforderungen an Prozesssensoren sowie an deren Kommunikationsfähigkeiten detaillierter zu beschreiben – vom einfachen Temperatursensor bis über heute in Entwicklung befindlichen Messsystemen hinaus –, da diese Technologieentwicklungen rasant voranschreiten. Vernetzte Sensoren sind die Voraussetzung für die Realisierung von Cyberphysischen Produktionssystemen (CPPS) und zukünftiger Automatisierungskonzepte für die Prozessindustrie, wie sie auch durch das Zukunftsprojekt "Industrie 4.0" adressiert werden.
Die Technologie-Roadmap liefert darüber hinaus Perspektiven für Forschungs- und Entwicklungsförderung und gibt Ansätze für die Normungsarbeit. Sie wird damit auch für Politik, Industrieverbände und Gremien von Interesse sein. Wenn sich die Exzellenz der Forschung und das ausgeprägte Know-how der Gerätehersteller und Anwender zu Forschungskonsortien auf Augenhöhe zusammentun und das Wissen gemeinsam vorangebracht wird, kommen faire und gut durchdachte Technologietransferprojekte mit Sicherheit zum Erfolg. Neben der technologischen Weiterentwicklung der Prozesssensoren ist von Herstellern und Anwendern die hohe Verfügbarkeit der komplexen Technologie sicherzustellen, damit weiterhin Vertrauen in die Technik besteht – vom Anwender bis ins Management.
Metalworking fluids (MWFs) are widely used to cool and lubricate metal workpieces during processing to reduce heat and friction. Extending a MWF’s service life is of importance from both economical and ecological points of view. Knowledge about the effects of processing conditions on the aging behavior and reliable analytical procedures are required to properly characterize the aging phenomena. While so far no quantitative estimations of ageing effects on MWFs have been described in the literature other than univariate ones based on single parameter measurements, in the present study we present a simple spectroscopy-based set-up for the simultaneous monitoring of three quality parameters of MWF and a mathematical model relating them to the most influential process factors relevant during use. For this purpose, the effects of MWF concentration, pH and nitrite concentration on the droplet size during aging were investigated by means of a response surface modelling approach. Systematically varied model MWF fluids were characterized using simultaneous measurements of absorption coefficients µa and effective scattering coefficients µ’s. Droplet size was determined via dynamic light scattering (DLS) measurements. Droplet size showed non-linear dependence on MWF concentration and pH, but the nitrite concentration had no significant effect. pH and MWF concentration showed a strong synergistic effect, which indicates that MWF aging is a rather complex process. The observed effects were similar for the DLS and the µ’s values, which shows the comparability of the methodologies. The correlations of the methods were R2c = 0.928 and R2P = 0.927, as calculated by a partial least squares regression (PLS-R) model. Furthermore, using µa, it was possible to generate a predictive PLS-R model for MWF concentration (R2c = 0.890, R2P = 0.924). Simultaneous determination of the pH based on the µ’s is possible with good accuracy (R²c = 0.803, R²P = 0.732). With prior knowledge of the MWF concentration using the µa-PLS-R model, the predictive capability of the µ’s-PLS-R model for pH was refined (10 wt%: R²c = 0.998, R²p = 0.997). This highlights the relevance of the combined measurement of µa and µ’s. Recognizing the synergistic nature of the effects of MWF concentration and pH on the droplet size is an important prerequisite for extending the service life of an MWF in the metalworking industry. The presented method can be applied as an in-process analytical tool that allows one to compensate for ageing effects during use of the MWF by taking appropriate corrective measures, such as pH correction or adjustment of concentration.
Rapid and robust quality monitoring of the composition of meat pastes is of fundamental importance in processing meat and sausage products. Here, an in-line near-infrared spectroscopy/micro-electro-mechanical-system-(MEMS)-based approach, combined with multivariate data analysis, was used for measuring the constituents fat, protein, water, and salt in meat pastes within a typical range of meat paste recipes. The meat pastes were spectroscopically characterized in-line with a novel process analyzer prototype. By integrating salt content in the calibration set, robust predictive PLSR models of high accuracy (R2 > 0.81) were obtained that take interfering matrix effects of the minor and NIR-inactive meat paste recipe component “salt” into account as well. The nonlinear blending behavior of salt concentration on the spectral features of meat pastes is discussed based on a designed mixture experiment with four systematically varied components.
Employing diffuse reflection ultraviolet visible (UV–Vis) spectroscopy we developed an approach that is capable to quantitatively determine flux residues on a technical copper surface. The technical copper surface was soldered with a no-clean flux system of organic acids. By a post-solder cleaning step with different cleaning parameters, various levels of residues were produced. The surface was quantitatively and qualitatively characterized using X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), Fourier transform infrared spectroscopy (FTIR) and diffuse reflection UV–Vis spectroscopy. With the use of a multivariate analysis (MVA) we examined the UV–Vis data to create a correlation to the carbon content on the surface. The UV–Vis data could be discriminated for all groups by their level of organic residues. Combined with XPS the data were evaluated by a partial least squares (PLS) regression to establish a model. Based on this predictive model, the carbon content was calculated with an absolute error of 2.7 at.%. Due to the high correlation of predictive model, the easy-to-use measurement and the evaluation by multivariate analysis the developed method seems suitable for an online monitoring system. With this system, flux residues can be detected in a manufacturing cleaning process of technical surfaces after soldering.
The properties of polyelectrolyte multilayers are ruled by the process parameters employed during self-assembly. This is the first study in which a design of experiment approach was used to validate and control the production of ultrathin polyelectrolyte multilayer coatings by identifying the ranges of critical process parameters (polyelectrolyte concentration, ionic strength and pH) within which coatings with reproducible properties (thickness, refractive index and hydrophilicity) are created. Mathematical models describing the combined impact of key process parameters on coatings properties were developed demonstrating that only ionic strength and pH affect the coatings thickness, but not polyelectrolyte concentration. While the electrolyte concentration had a linear effect, the pH contribution was described by a quadratic polynomial. A significant contribution of this study is the development of a new approach to estimate the thickness of polyelectrolyte multilayer nanofilms by quantitative rhodamine B staining, which might be useful in all cases when ellipsometry is not feasible due to the shape complexity or small size of the coated substrate. The novel approach proposed here overcomes the limitations of known methods as it offers a low spatial sampling size and the ability to analyse a wide area without restrictions on the chemical composition and shape of the substrate.
For optimization of production processes and product quality, often knowledge of the factors influencing the process outcome is compulsory. Thus, process analytical technology (PAT) that allows deeper insight into the process and results in a mathematical description of the process behavior as a simple function based on the most important process factors can help to achieve higher production efficiency and quality. The present study aims at characterizing a well-known industrial process, the transesterification reaction of rapeseed oil with methanol to produce fatty acid methyl esters (FAME) for usage as biodiesel in a continuous micro reactor set-up. To this end, a design of experiment approach is applied, where the effects of two process factors, the molar ratio and the total flow rate of the reactants, are investigated. The optimized process target response is the FAME mass fraction in the purified nonpolar phase of the product as a measure of reaction yield. The quantification is performed using attenuated total reflection infrared spectroscopy in combination with partial least squares regression. The data retrieved during the conduction of the DoE experimental plan were used for statistical analysis. A non-linear model indicating a synergistic interaction between the studied factors describes the reactor behavior with a high coefficient of determination (R²) of 0.9608. Thus, we applied a PAT approach to generate further insight into this established industrial process.
Newly developed active pharmaceutical ingredients (APIs) are often poorly soluble in water. As a result the bioavailability of the API in the human body is reduced. One approach to overcome this restriction is the formulation of amorphous solid dispersions (ASDs), e.g., by hot-melt extrusion (HME). Thus, the poorly soluble crystalline form of the API is transferred into a more soluble amorphous form. To reach this aim in HME, the APIs are embedded in a polymer matrix. The resulting amorphous solid dispersions may contain small amounts of residual crystallinity and have the tendency to recrystallize. For the controlled release of the API in the final drug product the amount of crystallinity has to be known. This review assesses the available analytical methods that have been recently used for the characterization of ASDs
and the quantification of crystalline API content. Well established techniques like near- and mid-infrared spectroscopy (NIR and MIR, respectively), Raman spectroscopy, and emerging ones like UV/VIS, terahertz, and ultrasonic spectroscopy are considered in detail. Furthermore, their advantages and limitations are discussed with regard to general practical applicability as process analytical technology (PAT) tools in industrial manufacturing. The review focuses on spectroscopic methods which have been proven as most suitable for in-line and on-line process analytics. Further aspects are spectroscopic techniques that have been or could be integrated into an extruder.
UV hyperspectral imaging (225 nm–410 nm) was used to identify and quantify the honey- dew content of real cotton samples. Honeydew contamination causes losses of millions of dollars annually. This study presents the implementation and application of UV hyperspectral imaging as a non-destructive, high-resolution, and fast imaging modality. For this novel approach, a reference sample set, which consists of sugar and protein solutions that were adapted to honeydew, was set-up. In total, 21 samples with different amounts of added sugars/proteins were measured to calculate multivariate models at each pixel of a hyperspectral image to predict and classify the amount of sugar and honeydew. The principal component analysis models (PCA) enabled a general differentiation between different concentrations of sugar and honeydew. A partial least squares regression (PLS-R) model was built based on the cotton samples soaked in different sugar and protein concentrations. The result showed a reliable performance with R2cv = 0.80 and low RMSECV = 0.01 g for the valida- tion. The PLS-R reference model was able to predict the honeydew content laterally resolved in grams on real cotton samples for each pixel with light, strong, and very strong honeydew contaminations. Therefore, inline UV hyperspectral imaging combined with chemometric models can be an effective tool in the future for the quality control of industrial processing of cotton fibers.
We report on the reflectance, transmittance and fluorescence spectra (λ=200–1200nm) of four types of chicken eggshells (white, brown, light green, dark green) measured in situ without pretreatment and after ablation of 20–100 μm of the outer shell regions. The color pigment protoporphyrin IX (PPIX) is embedded in the protein phase of all four shell types as highly fluorescent monomers, in the white and light green shells additionally as non-fluorescent dimers, and in the brown and dark green shells mainly as non-fluorescent poly-aggregates. The green shell colors are formed from an approximately equimolar mixture of PPIX and biliverdin. The axial distribution of protein and color pigments were evaluated from the combined reflectances of both the outer and inner shell surfaces, as well as from the transmittances. For the data generation we used the radiative transfer model in the random walk and Kubelka-Munk approaches.
A systematic study using a central composite design of experiments (DoE) was performed on the oxygen plasma surface modifications of two different polymers—Pellethane 2363-55DE, which is a polyurethane, and vinyltrimethoxysilane-grafted ethylene-propylene (EPR-g-VTMS), a cross-linked ethylene-propylene rubber. The impacts of four parameters—gas pressure, generator power, treatment duration, and process temperature—were assessed, with static contact angles and calculated surface free energies (SFEs) as the main responses in the DoE. The plasma effects on the surface roughness and chemistry were determined using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Through the sufficiently accurate DoE model evaluation, oxygen gas pressure was established as the most impactful factor, with the surface energy and polarity rising with falling oxygen pressure. Both polymers, though different in composition, exhibited similar modification trends in surface energy rise in the studied system. The SEM images showed a rougher surface topography after low pressure plasma treatments. XPS and subsequent multivariate data analysis of the spectra established that higher oxidized species were formed with plasma treatments at low oxygen pressures of 0.2 mbar.
Optofluidics
(2019)
This introduction into the multidisciplinary area of optofluidics offers the necessary foundations in photonics, polymer physics and process analytics to students, engineers and researchers to enter the field. All basic ingredients of a polymer-based platform as a foundation for quick and compact solutions for chemical, biological and medical sensing and manipulation are developed.
Commercially available homogenized cow- and plant-based milks were investigated by optical spectroscopy in the range of 400–1360 nm. Absorbance spectra, the effective scattering coefficient μs′, and the spectral absorption coefficient μa were recorded for 23 milk varieties and analyzed by multivariate data analysis. Cow- and plant-based milks were compared and discriminated using principal component analysis combined with a quadratic discriminant analysis. Furthermore, it was possible to discriminate the origin of plant-based milk by μa and the fat content in cow-based milk by μs′. Partial least squares regression models were developed to determine the fat content in cow-based milk. The model for μs′ proved to be the most efficient for this task with R2 = 0.98 and RMSEP = 0.19 g/100 mL for the external validation. Thus, optical spectroscopy together with multivariate data analysis is suitable for routine laboratory analysis or quality monitoring in the dairy production.
Current techniques for chromosome analysis need to be improved for rapid, economical identification of complex chromosomal defects by sensitive and selective visualisation. In this paper, we present a straightforward method for characterising unstained human metaphase chromosomes. Backscatter imaging in a dark-field setup combined with visible and short near-infrared spectroscopy is used to monitor morphological differences in the distribution of the chromosomal fine structure in human metaphase chromosomes. The reasons for the scattering centres in the fine structure are explained. Changes in the scattering centres during preparation of the metaphases are discussed. FDTD simulations are presented to substantiate the experimental findings. We show that local scattering features consisting of underlying spectral modulations of higher frequencies associated with a high variety of densely packed chromatin can be represented by their scatter profiles even on a sub-microscopic level. The result is independent of the chromosome preparation and structure size. This analytical method constitutes a rapid, costeffective and label-free cytogenetic technique which can be used in a standard light microscope.
Characterization of brain tumours requires neuropathological expertise and is generally performed by histological evaluation and molecular analysis. One emerging technique to assist pathologists in future tumour diagnostics is multimodal optical spectroscopy. In the current clinical routine, tissue preprocessing with formalin is widely established and suitable for spectroscopic investigations since degradation processes impede the measurement of native tissue. However, formalin fixation results in alterations of the tissue chemistry and morphology for example by protein cross-linking. As optical spectroscopy is sensitive to these variations, we evaluate the effects of formalin fixation on multimodal brain tumour data in this proof-of-concept study. Nonfixed and formalin-fixed cross sections of different common human brain tumours were subjected to analysis of chemical variations using ultraviolet and Fourier-transform infrared microspectroscopy. Morphological changes were assessed by elastic light scattering microspectroscopy in the visible wavelength range. Data were analysed with multivariate data analysis and compared with histopathology. Tissue type classifications deduced by optical spectroscopy are highly comparable and independent from the preparation and the fixation protocol. However, formalin fixation leads to slightly better classification models due to improved stability of the tissue. As a consequence, spectroscopic methods represent an appropriate additional contrast for chemical and morphological information in neuropathological diagnosis and should be investigated to a greater extent. Furthermore, they can be included in the clinical workflow even after formalin fixation.