Refine
Document Type
- Journal article (36)
- Book chapter (1)
Language
- English (37)
Is part of the Bibliography
- yes (37)
Institute
- Life Sciences (37)
Publisher
- Elsevier (7)
- MDPI (7)
- Wiley (5)
- De Gruyter (4)
- ACS (3)
- American Chemical Society (3)
- IIAR (2)
- BAN (1)
- Frontiers Media (1)
- Pan Stanford Publishing (1)
In this article, liposome-based coatings aiming to control drug release from therapeutic soft contact lenses (SCLs) materials are analyzed. A PHEMA based hydrogel material loaded with levofloxacin is used as model system for this research. The coatings are formed by polyelectrolyte layers containing liposomes of 1,2-dimyristoyl-sn-glycero-3- phosphocholine (DMPC) and DMPC1cholesterol (DMPC1 CHOL). The effect of friction and temperature on the drug release is investigated. The aim of the friction tests is to simulate the blinking of the eyelid in order to verify if the SCLs materials coated with liposomes are able to keep their properties, in particular the drug release ability. It was observed that under the study conditions, friction did not affect significantly the drug release from the liposome coated PHEMA material. In contrast, increasing the temperature of release leads to an increase of the drug diffusion rate through the hydrogel. This phenomenon is recorded both in the control and in the coated samples.
In this study, a novel strategy has been developed for the assembly of polyelectrolyte multilayer (PEM) on CaCO3 templates in acidic pH solutions, where consecutive polyelectrolyte layers (heparin/poly(allylamine hydrochloride) or heparin/chitosan) were deposited on PEM hollow microcapsules established previously on CaCO3 templates. The PEM build-up, hollow capsule characterization and successful encapsulation of fluorescein 5(6)-isothiocyanate (FITC)-Dextran by coprecipitation with CaCO3 are demonstrated. Improvement by the removal of CaCO3 core was achieved while the depositions. In the course of the release profile, high retardation for encapsulated FITC-Dextran was observed. The combined shell capsules system is a significant trait that has potential use in tailoring functional layer-by-layer capsules as intelligent drug delivery vehicles where the preliminary in vitro tests showed the responsiveness on the enzymes.
Polyelectrolyte multilayer (PEM) are thin polymeric films produced by alternating adsorption of positively and negatively charged polyelectrolytes (PE) on a substrate. These films are considered drug delivery agents as well as coating material for implants, due to their antibiofouling and biologically benign properties. For these reasons the film mechanical properties as well as response to mechanical stress are important measurement parameters. Especially intriguing is the correlation of the mechanical properties of PEM on macroscopic level with the structure of PEM on molecular level, which is addressed here for the first time. This study investigates PEM from PDADMA/PSS produced by spraying technique with neutron and X-ray reflectometry. Reflectometry technique provides precise information on thickness and density (i.e., electron density or scattering length density, respectively), and, this way, allows to conclude on changes in film composition. Thus, neutron and X-ray reflectometry technique is suitable to investigate the overall and the internal transformations, which PEM films might undergo upon exposure to mechanical load. During uniaxial elongation two regimes of PEM deformation can be observed: An elastic regime at small elongations (below ca. 0.2%), which is characterized by a reversible change of film thickness, and a plastic regime with a permanent change above this limit. Both regimes have in common, that the mechanical load induces an increase of the film thickness, which is accompanied by an uptake of water from the surrounding atmosphere. The strain causes a molecular rearrangement within the PEM-structure of stratified layers, which, even in elastic regime, is permanent, although the thickness change remains reversible.
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.
Surface topographies are often discussed as an important parameter influencing basic cell behavior. Whereas most in vitro studies deal with microstructures with sharp edges, smooth, curved microscale topographies might be more relevant concerning in-vivo situations. Addressing the lack of highly defined surfaces with varying curvature, we present a topography chip system with 3D curved features of varying spacing, curvature radii as well as varying overall dimensions of curved surfaces. The CurvChip is produced by low-cost photolithography with thermal reflow, subsequent (repetitive) PDMS molding and hot embossing. The platform facilitates the systematic in-vitro investigation of the impact of substrate curvature on cell types like epithelial, endothelial, smooth muscle cells, or stem cells. Such investigations will not only help to further understand the mechanism of curvature sensation but may also contribute to optimize cell-material interactions in the field of regenerative medicine.
The present publication reports the purification effort of two natural bone blocks, that is, an allogeneic bone block (maxgraft®, botiss biomaterials GmbH, Zossen, Germany) and a xenogeneic block (SMARTBONE®, IBI S.A., Mezzovico Vira, Switzerland) in addition to previously published results based on histology. Furthermore, specialized scanning electron microscopy (SEM) and in vitro analyses (XTT, BrdU, LDH) for testing of the cytocompatibility based on ISO 10993-5/-12 have been conducted. The microscopic analyses showed that both bone blocks possess a trabecular structure with a lamellar subarrangement. In the case of the xenogeneic bone block, only minor remnants of collagenous structures were found, while in contrast high amounts of collagen were found associated with the allogeneic bone matrix. Furthermore, only island-like remnants of the polymer coating in case of the xenogeneic bone substitute seemed to be detectable. Finally, no remaining cells or cellular remnants were found in both bone blocks. The in vitro analyses showed that both bone blocks are biocompatible. Altogether, the purification level of both bone blocks seems to be favorable for bone tissue regeneration without the risk for inflammatory responses or graft rejection. Moreover, the analysis of the maxgraft® bone block showed that the underlying purification process allows for preserving not only the calcified bone matrix but also high amounts of the intertrabecular collagen matrix.
The aim of this study was to predefine the pore structure of β-tricalcium phosphate (β-TCP) scaffolds with different macro pore sizes (500, 750, and 1000 µm), to characterize β-TCP scaffolds, and to investigate the growth behavior of cells within these scaffolds. The lead structures for directional bone growth (sacrificial structures) were produced from polylactide (PLA) using the fused deposition modeling techniques. The molds were then filled with β-TCP slurry and sintered at 1250° C, whereby the lead structures (voids) were burnt out. The scaffolds were mechanically characterized (native and after incubation in simulated body fluid (SBF) for 28 d). In addition, biocompatibility was investigated by live/dead, cell proliferation and lactate dehydrogenase assays.
Background/Aim: The aim of this study was the development of a new osteoconductivity index to determine the bone healing capacities of bone substitute materials (BSM) on the basis of 3D microcomputed tomographic (μ-CT) data. Materials and Methods: Sinus biopsies were used for the comparative analysis of the integration behavior of two xenogeneic BSM (cerabone® and Bio Oss®). 3D μ-CT and data sets from histomorphometrical measurements based on 2D histological slices were used to measure the bone-material-contact and the tissue distribution within the biopsies. The tissue reactions to both BSM were microscopically analyzed. Results: The 3D and 2D results of the osteoconductivity measurements showed comparable material-bone contacts for both BSM, but the 2D data were significantly lower. The same results were found when tissue distribution was measured in both groups. The histopathological analysis showed comparative tissue reactions in both BSM. Conclusion: Osteoconductivity index is a reliable measurement parameter for determining the healing capacities of BSM. The observed differences between both measurement methods could be assigned to the resolution capacity of μ-CT data that did not allow for a precise interface distinction between both BSM and bone tissue. Histomorphometrical data based on histological slides still allow for a more exact evaluation.
Medical implants play a central role in modern medicine and both, naturally derived and synthetic materials have been explored as biomaterials for such devices. However, when implanted into living tissue, most materials initiate a host response. In addition, implants often cause bacterial infections leading to complications. Polyelectrolyte multilayer (PEM) coatings can be used for functionalization of medical implants improving the implant integration and reducing foreign body reactions. Some PEMs are also known to show antibacterial properties. We developed a PEM coating suggesting that it can decrease the risk of bacterial infections occurring after implantation while being highly biocompatible. We applied two different standard tests for evaluating the PEM’s antibacterial properties, the ISO norm (ISO 22196) and one ASTM norm (ASTM E2180) test. We found a reduction of bacterial growth on the PEM but to a different degree depending on the testing method. This result demonstrates the need for defining proper method to evaluate antibacterial properties of surface coatings.
Controlling the surface properties and structure of thin nanosized coatings is of primary importance in diverse engineering and medical applications. Here we report on how the nanostructure, growth mechanism, thickness, roughness, and hydrophilicity of nanocomposites composed of weak natural or strong synthetic polyelectrolytes (PE) can be tailored by graphene oxide (GO) doping. GO reverses the build‐up mechanism affecting the internal structure and the hydrophilicity in a way depending on the type of the PE‐matrix. The extent of GO‐adsorption and its impact on the surface morphology was found to be independent on the type of the underlying PE‐matrix. The nanostructure of the hybrid films is not significantly altered when a single surface‐exposed GO‐layer is deposited, while increasing the number of embedded GO‐layers leads to pronounced surface heterogeneity. These results are expected to have valuable impact on the construction strategies of coatings with tunable surface properties.