Boost converters suffer from a bandwidth limitation caused by the right-half plane zero (RHPZ), which occurs in the control-to-output transfer function. In contrast, there are many applications that require superior dynamic behavior. Further, size and cost of boost converter systems can be minimized by reduced voltage deviations and fast transient responses in case of large signal load transients. The key idea of the proposed ΔV/Δt-intervention control concept is to adapt the controller output to its new steady state value immediately after a load transient by prediction from known parameters. The concept is implemented in a digital control circuit, consisting of an ASIC in a 110 nm-technology and a Xilinx Spartan-6 field programmable gate array (FPGA). In a boost converter with 3.5V input voltage, 6.3V output voltage, 1.2A load, and 500 kHz switching frequency, the output voltage deviations are 2.8x smaller, scaling down the output capacitor value by the same factor. The recovery times are 2.4x shorter in case of large signal load transients with the proposed concept. The control is widely applicable, as it supports constant switching frequencies and allows for duty cycle and inductor current limitations. It also shows various advantages compared to conventional control and to selected adaptive control concepts.
This paper presents a digitally controlled boost converter IC for high output voltage and fast transient applications. Thus, it is well applicable in automotive and industrial environments. The 3V-to-6V input voltage, 6.3V output voltage, 1A boost converter IC is fabricated in a 180nm BCD technology. Digital control enables cost savings, advanced control concepts, and it is less parameter sensitive compared to common analog control. A 90 ns latency, 6-bit delay line ADC operates with a window concept, meeting high resolution requirements, e.g. in car battery applications. An output voltage live tracking is included for extending the ADC conversion window. A charge pump DAC provides high resolution, monotonicity, and short 128 ns conversion time. Further, a standard digital PI controller is enhanced by a simple but effective ΔV/Δt-intervention control. It results in 2.8x reduced output voltage deviations in case of load steps, scaling down the output capacitor value by the same factor.