Informatik
Refine
Year of publication
Document Type
- Journal article (199) (remove)
Is part of the Bibliography
- yes (199)
Institute
- Informatik (199)
- ESB Business School (1)
Publisher
- Elsevier (44)
- Springer (39)
- De Gruyter (14)
- MDPI (10)
- Emerald (7)
- IARIA (7)
- IEEE (7)
- Association for Computing Machinery (4)
- Riga Technical University Press (4)
- Wiley (4)
Viele Unternehmen befassen sich in jüngster Zeit mit der Nutzung von Social Media für die interne Kommunikation und Zusammenarbeit. So genannte Enterprise Social Networks bieten integrierte Plattformen mit Profilen, Blogs, Gruppen- und Kommentarfunktionen für die unternehmensinterne Anwendung. Sehr häufig sind damit umfangreiche Investitionen verbunden. Die Budgets werden im Kern für die IT verwendet, "weiche Faktoren" bleiben häufig außen vor. Ein schwerer Fehler, wie aktuelle Marktstudien zeigen. Etliche der ambitionierten Projekte drohen daher zu scheitern.
A behavior marker for measuring non-technical skills of software professionals : an empirical study
(2015)
Managers recognize that software development teams need to be developed. Although technical skills are necessary, non-technical (NT) skills are equally, if not more, necessary for project success. Currently, there are no proven tools to measure the NT skills of software developers or software development teams. Behavioral markers (observable behaviors that have positive or negative impacts on individual or team performance) are successfully used by airline and medical industries to measure NT skill performance. This research developed and validated a behavior marker tool rated video clips of software development teams. The initial results show that the behavior marker tool can be reliably used with minimal training.
Artificial intelligence (AI) is one of the most promising technologies of the post-pandemic era. Cloud computing technology can simplify the process of developing AI applications by offering a variety of services, including ready-to-use tools to train machine learning (ML) algorithms. However, comparing the vast amount of services offered by different providers and selecting a suitable cloud service can be a major challenge for many firms. Also in academia, suitable criteria to evaluate this type of service remain largely unclear. Therefore, the overall aim of this work has been to develop a framework to evaluate cloud-based ML services. We use Design Science Research as our methodology and conduct a hermeneutic literature review, a vendor analysis, as well as, expert interviews. Based on our research, we present a novel framework for the evaluation of cloud-based ML services consisting of six categories and 22 criteria that are operationalized with the help of various metrics. We believe that our results will help organizations by providing specific guidance on how to compare and select service providers from the vast amount of potential suppliers.
Context:
Test-driven development (TDD) is an agile software development approach that has been widely claimed to improve software quality. However, the extent to which TDD improves quality appears to be largely dependent upon the characteristics of the study in which it is evaluated (e.g., the research method, participant type, programming environment, etc.). The particularities of each study make the aggregation of results untenable.
Objectives:
The goal of this paper is to: increase the accuracy and generalizability of the results achieved in isolated experiments on TDD, provide joint conclusions on the performance of TDD across different industrial and academic settings, and assess the extent to which the characteristics of the experiments affect the quality-related performance of TDD.
Method:
We conduct a family of 12 experiments on TDD in academia and industry. We aggregate their results by means of meta-analysis. We perform exploratory analyses to identify variables impacting the quality-related performance of TDD.
Results:
TDD novices achieve a slightly higher code quality with iterative test-last development (i.e., ITL, the reverse approach of TDD) than with TDD. The task being developed largely determines quality. The programming environment, the order in which TDD and ITL are applied, or the learning effects from one development approach to another do not appear to affect quality. The quality-related performance of professionals using TDD drops more than for students. We hypothesize that this may be due to their being more resistant to change and potentially less motivated than students.
Conclusion:
Previous studies seem to provide conflicting results on TDD performance (i.e., positive vs. negative, respectively). We hypothesize that these conflicting results may be due to different study durations, experiment participants being unfamiliar with the TDD process, or case studies comparing the performance achieved by TDD vs. the control approach (e.g., the waterfall model), each applied to develop a different system. Further experiments with TDD experts are needed to validate these hypotheses.
Purpose – Many start-ups are in search of cooperation partners to develop their innovative business models. In response, incumbent firms are introducing increasingly more cooperation systems to engage with startups. However, many of these cooperations end in failure. Although qualitative studies on cooperation models have tried to improve the effectiveness of incumbent start-up strategies, only a few have empirically examined start-up cooperation behavior. The paper aims to discuss these issues.
Design/methodology/approach – Drawing from a series of qualitative and quantitative studies. The scale dimensions are identified on an interview based qualitative study. Following workshops and questionnaire-based studies identify factors and rank them. These ranked factors are then used to build a measurement scale that is integrated in a standardized online questionnaire addressing start-ups. The gathered data are then analyzed using PLS-SEM.
Findings – The research was able to build a multi-item scale for start-ups cooperation behavior. This scale can be used in future research. The paper also provides a causal analysis on the impact of cooperation behavior on start-up performance. The research finds, that the found dimensions are suitable for measuring cooperation behavior. It also shows a minor positive effect on start-up’s performance.
Originality/value – The research fills the gap of lacking empirical research on the cooperation between start-ups and established firms. Also, most past studies focus on organizational structures and their performance when addressing these cooperations. Although past studies identified the start-ups behavior as a relevant factor, no empirical research has been conducted on the topic yet.
Purpose
Supporting the surgeon during surgery is one of the main goals of intelligent ORs. The OR-Pad project aims to optimize the information flow within the perioperative area. A shared information space should enable appropriate preparation and provision of relevant information at any time before, during, and after surgery.
Methods
Based on previous work on an interaction concept and system architecture for the sterile OR-Pad system, we designed a user interface for mobile and intraoperative (stationary) use, focusing on the most important functionalities like clear information provision to reduce information overload. The concepts were transferred into a high-fidelity prototype for demonstration purposes. The prototype was evaluated from different perspectives, including a usability study.
Results
The prototype’s central element is a timeline displaying all available case information chronologically, like radiological images, labor findings, or notes. This information space can be adapted for individual purposes (e.g., highlighting a tumor, filtering for own material). With the mobile and intraoperative mode of the system, relevant information can be added, preselected, viewed, and extended during the perioperative process. Overall, the evaluation showed good results and confirmed the vision of the information system.
Conclusion
The high-fidelity prototype of the information system OR-Pad focuses on supporting the surgeon via a timeline making all available case information accessible before, during, and after surgery. The information space can be personalized to enable targeted support. Further development is reasonable to optimize the approach and address missing or insufficient aspects, like the holding arm and sterility concept or new desired features.
Introduction
Despite its high accuracy, polysomnography (PSG) has several drawbacks for diagnosing obstructive sleep apnea (OSA). Consequently, multiple portable monitors (PMs) have been proposed.
Objective
This systematic review aims to investigate the current literature to analyze the sets of physiological parameters captured by a PM to select the minimum number of such physiological signals while maintaining accurate results in OSA detection.
Methods
Inclusion and exclusion criteria for the selection of publications were established prior to the search. The evaluation of the publications was made based on one central question and several specific questions.
Results
The abilities to detect hypopneas, sleep time, or awakenings were some of the features studied to investigate the full functionality of the PMs to select the most relevant set of physiological signals. Based on the physiological parameters collected (one to six), the PMs were classified into sets according to the level of evidence. The advantages and the disadvantages of each possible set of signals were explained by answering the research questions proposed in the methods.
Conclusions
The minimum number of physiological signals detected by PMs for the detection of OSA depends mainly on the purpose and context of the sleep study. The set of three physiological signals showed the best results in the detection of OSA.
Purpose: This paper aims to conceptualize and empirically test the determinants of service interaction quality (SIQ) as attitude, behavior and expertise of a service provider (SP). Further, the individual and simultaneous effects of SIQ and its dimensions on important marketing outcomes are tested. Design/methodology/approach – The narrative review of extant research helps formulate a conceptual model of SIQ, which is investigated using the univariate and multivariate meta-analysis.
Findings: There are interdependencies between drivers of SIQ that underlines the need to conceptualize service interaction as a dyadic phenomenon; use contemporary multilevel models, dyadic models, non-linear structural equation modeling and process studies; and study new and diverse services contexts. Meta-analysis illustrates the relative importance of the three drivers of SIQ and, in turn, their impact on consumer satisfaction and loyalty.
Research limitations/implications – The meta-analysis is based on existing research, which, unfortunately, has not examined critical services or exigency situations where SIQ is of paramount importance. Future research will be tasked with diversifying to several important domains where SIQ is a critical aspect of perceived service quality.
Practical implications: This study emphasizes that, although the expertise of an SP is important, firms would be surprised to learn that the attitude and behavior of their employees are equally important antecedents. In fact, there is a delicate balance that needs to be found; otherwise, attitudinal factors can have an overall counterproductive effect on consumer satisfaction.
Originality/value: This paper provides an empirical synthesis of SIQ and opens up interesting areas for further research.
In this note we look at anisotropic approximation of smooth functions on bounded domains with tensor product splines. The main idea is to extend such functions and then use known approximation techniques on Rd. We prove an error estimate for domains for which bounded extension operators exist. This obvious approach has some limitations. It is not applicable without restrictions on the chosen coordinate degree even if the domain is as simple as the unit disk. Further for approximation on Rd there are error estimates in which the grid widths and directional derivatives are paired in an interesting way. It seems impossible to maintain this property using extension operators.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.