Informatik
Refine
Year of publication
- 2022 (85) (remove)
Document Type
- Conference proceeding (50)
- Journal article (31)
- Book chapter (2)
- Doctoral Thesis (1)
- Anthology (1)
Is part of the Bibliography
- yes (85)
Institute
- Informatik (85)
Publisher
- Springer (24)
- Hochschule Reutlingen (10)
- Elsevier (7)
- IEEE (6)
- De Gruyter (4)
- University of Hawai'i at Manoa (3)
- ACM (2)
- Association for Information Systems (AIS) (2)
- IADIS (2)
- IARIA (2)
Nowadays, the importance of early active patient mobilization in the recovery and rehabilitation phase has increased significantly. One way to involve patients in the treatment is a gamification-like approach, which is one of the methods of motivation in various life processes. This article shows a system prototype for patients who require physical activity because of active early mobilization after medical interventions or during illness. Bedridden patients and people with a sedentary lifestyle (predominantly lying in bed) are also potential users. The main idea for the concept was non-contact system implementation for the patients making them feel effortless during its usage. The system consists of three related parts: hardware, software, and game application. To test the relevance and coherence of the system, it was used by 35 people. The participants were asked to play a video game requiring them to make body movements while lying down. Then they were asked to take part in a small survey to evaluate the system's usability. As a result, we offer a prototype consisting of hardware and software parts that can increase and diversify physical activity during active early mobilization of patients and prevent the occurrence of possible health problems due to predominantly low activity. The proposed design can be possibly implemented in hospitals, rehabilitation centers, and even at home.
Sleep analysis using a Polysomnography system is difficult and expensive. That is why we suggest a non-invasive and unobtrusive measurement. Very few people want the cables or devices attached to their bodies during sleep. The proposed approach is to implement a monitoring system, so the subject is not bothered. As a result, the idea is a non-invasive monitoring system based on detecting pressure distribution. This system should be able to measure the pressure differences that occur during a single heartbeat and during breathing through the mattress. The system consists of two blocks signal acquisition and signal processing. This whole technology should be economical to be affordable enough for every user. As a result, preprocessed data is obtained for further detailed analysis using different filters for heartbeat and respiration detection. In the initial stage of filtration, Butterworth filters are used.
With the progress of technology in modern hospitals, an intelligent perioperative situation recognition will gain more relevance due to its potential to substantially improve surgical workflows by providing situation knowledge in real-time. Such knowledge can be extracted from image data by machine learning techniques but poses a privacy threat to the staff’s and patients’ personal data. De-identification is a possible solution for removing visual sensitive information. In this work, we developed a YOLO v3 based prototype to detect sensitive areas in the image in real-time. These are then deidentified using common image obfuscation techniques. Our approach shows that it is principle suitable for de-identifying sensitive data in OR images and contributes to a privacyrespectful way of processing in the context of situation recognition in the OR.
Theoretical foundation, effectiveness, and design artefact for machine learning service repositories
(2022)
Machine learning (ML) has played an important role in research in recent years. For companies that want to use ML, finding the algorithms and models that fit for their business is tedious. A review of the available literature on this problem indicates only a few research papers. Given this gap, the aim of this paper is to design an effective and easy-to-use ML service repository. The corresponding research is based on a multi-vocal literature analysis combined with design science research, addressing three research questions: (1) How is current white and gray literature on ML services structured with respect to repositories? (2) Which features are relevant for an effective ML service repository? (3) How is a prototype for an effective ML service repository conceptualized? Findings are relevant for the explanation of user acceptance of ML repositories. This is essential for corporate practice in order to create and use ML repositories effectively.
In our initial DaMoN paper, we set out the goal to revisit the results of “Starring into the Abyss [...] of Concurrency Control with [1000] Cores” (Yu in Proc. VLDB Endow 8: 209-220, 2014). Against their assumption, today we do not see single-socket CPUs with 1000 cores. Instead, multi-socket hardware is prevalent today and in fact offers over 1000 cores. Hence, we evaluated concurrency control (CC) schemes on a real (Intel-based) multi-socket platform. To our surprise, we made interesting findings opposing results of the original analysis that we discussed in our initial DaMoN paper. In this paper, we further broaden our analysis, detailing the effect of hardware and workload characteristics via additional real hardware platforms (IBM Power8 and 9) and the full TPC-C transaction mix. Among others, we identified clear connections between the performance of the CC schemes and hardware characteristics, especially concerning NUMA and CPU cache. Overall, we conclude that no CC scheme can efficiently make use of large multi-socket hardware in a robust manner and suggest several directions on how CC schemes and overall OLTP DBMS should evolve in future.
Even though near-data processing (NDP) can provably reduce data transfers and increase performance, current NDP is solely utilized in read-only settings. Slow or tedious to implement synchronization and invalidation mechanisms between host and smart storage make NDP support for data-intensive update operations difficult. In this paper, we introduce a low-latency cache-coherent shared lock table for update NDP settings in disaggregated memory environments. It utilizes the novel CCIX interconnect technology and is integrated in neoDBMS, a near-data processing DBMS for smart storage. Our evaluation indicates end-to-end lock latencies of ∼80-100ns and robust performance under contention.
Multi-versioning and MVCC are the foundations of many modern DBMSs. Under mixed workloads and large datasets, the creation of the transactional snapshot can become very expensive, as long-running analytical transactions may request old versions, residing on cold storage, for reasons of transactional consistency. Furthermore, analytical queries operate on cold data, stored on slow persistent storage. Due to the poor data locality, snapshot creation may cause massive data transfers and thus lower performance. Given the current trend towards computational storage and near-data processing, it has become viable to perform such operations in-storage to reduce data transfers and improve scalability. neoDBMS is a DBMS designed for near-data processing and computational storage. In this paper, we demonstrate how neoDBMS performs snapshot computation in-situ. We showcase different interactive scenarios, where neoDBMS outperforms PostgreSQL 12 by up to 5×.
Gamification is one of the recognized methods of motivating people in various life processes, and it has spread to many spheres of life, including healthcare. This article proposes a system design for long-term care patients using the method mentioned. The proposed system aims to increase patient engagement in the treatment and rehabilitation process via gamification. Literature research on available and earlier proposed systems was conducted to develop a suited system design. The primary target group includes bedridden patients and a sedentary lifestyle (predominantly lying in bed). One of the main criteria for selecting a suitable option was its contactless realization for the mentioned target groups in long-term care cases. As a result, we developed the system design for hardware and software that could prevent bedsores and other health problems from occurring because of low activity. The proposed design can be tested in hospitals, nursing homes, and rehabilitation centers.
Determination of accelerometer sensor position for respiration rate detection: initial research
(2022)
Continuous monitoring of a patient's vital signs is essential in many chronic illnesses. The respiratory rate (RR) is one of the vital signs indicating breathing diseases. This article proposes the initial investigation for determining the accelerometric sensor position of a non-invasive and unobtrusive respiratory rate monitoring system. This research aims to determine the sensor position in relation to the patient, which can provide the most accurate values of the mentioned physiological parameter. In order to achieve the result, the particular system setup, including a mechanical sensor holder construction was used. The breathing signals from 5 participants were analyzed corresponding to the relaxed state. The main criterion for selecting a suitable sensor position was each patient's average acceleration amplitude excursion, which corresponds to the respiratory signal. As a result, we provided one more defined important parameter for the considered system, which was not determined before.
The respiratory rate is a vital sign indicating breathing illness. It is necessary to analyze the mechanical oscillations of the patient's body arising from chest movements. An inappropriate holder on which the sensor is mounted, or an inappropriate sensor position is some of the external factors which should be minimized during signal registration. This paper considers using a non-invasive device placed under the bed mattress and evaluates the respiratory rate. The aim of the work is the development of an accelerometer sensor holder for this system. The normal and deep breathing signals were analyzed, corresponding to the relaxed state and when taking deep breaths. The evaluation criterion for the holder's model is its influence on the patient's respiratory signal amplitude for each state. As a result, we offer a non-invasive system of respiratory rate detection, including the mechanical component providing the most accurate values of mentioned respiratory rate.