Informatik
Refine
Document Type
- Journal article (28) (remove)
Has full text
- yes (28)
Is part of the Bibliography
- yes (28)
Institute
- Informatik (28)
Publisher
- Springer (28) (remove)
Software evolvability is an important quality attribute, yet one difficult to grasp. A certain base level of it is allegedly provided by service- and microservice-based systems, but many software professionals lack systematic understanding of the reasons and preconditions for this. We address this issue via the proxy of architectural modifiability tactics. By qualitatively mapping principles and patterns of Service Oriented Architecture (SOA) and microservices onto tactics and analyzing the results, we cannot only generate insights into service-oriented evolution qualities, but can also provide a modifiability comparison of the two popular service-based architectural styles. The results suggest that both SOA and microservices possess several inherent qualities beneficial for software evolution. While both focus strongly on loose coupling and encapsulation, there are also differences in the way they strive for modifiability (e.g. governance vs. evolutionary design). To leverage the insights of this research, however, it is necessary to find practical ways to incorporate the results as guidance into the software development process.
Turning students into Industry 4.0 entrepreneurs: design and evaluation of a tailored study program
(2022)
Startups in the field of Industry 4.0 could be a huge driver of innovation for many industry sectors such as manufacturing. However, there is a lack of education programs to ensure a sufficient number of well-trained founders and thus a supply of such startups. Therefore, this study presents the design, implementation, and evaluation of a university course tailored to the characteristics of Industry 4.0 entrepreneurship. Educational design-based research was applied with a focus on content and teaching concept. The study program was first implemented in 2021 at a German university of applied sciences with 25 students, of which 22 participated in the evaluation. The evaluation of the study program was conducted with a pretest–posttest-design targeting three areas: (1) knowledge about the application domain, (2) entrepreneurial intention and (3) psychological characteristics. The entrepreneurial intention was measured based on the theory of planned behavior. For measuring psychological characteristics, personality traits associated with entrepreneurship were used. Considering the study context and the limited external validity of the study, the following can be identified in particular: The results show that a university course can improve participants' knowledge of this particular area. In addition, perceived behavioral control of starting an Industry 4.0 startup was enhanced. However, the results showed no significant effects on psychological characteristics.
Purpose
For the modeling, execution, and control of complex, non-standardized intraoperative processes, a modeling language is needed that reflects the variability of interventions. As the established Business Process Model and Notation (BPMN) reaches its limits in terms of flexibility, the Case Management Model and Notation (CMMN) was considered as it addresses weakly structured processes.
Methods
To analyze the suitability of the modeling languages, BPMN and CMMN models of a Robot-Assisted Minimally Invasive Esophagectomy and Cochlea Implantation were derived and integrated into a situation recognition workflow. Test cases were used to contrast the differences and compare the advantages and disadvantages of the models concerning modeling, execution, and control. Furthermore, the impact on transferability was investigated.
Results
Compared to BPMN, CMMN allows flexibility for modeling intraoperative processes while remaining understandable. Although more effort and process knowledge are needed for execution and control within a situation recognition system, CMMN enables better transferability of the models and therefore the system. Concluding, CMMN should be chosen as a supplement to BPMN for flexible process parts that can only be covered insufficiently by BPMN, or otherwise as a replacement for the entire process.
Conclusion
CMMN offers the flexibility for variable, weakly structured process parts, and is thus suitable for surgical interventions. A combination of both notations could allow optimal use of their advantages and support the transferability of the situation recognition system.
Container virtualization evolved into a key technology for deployment automation in line with the DevOps paradigm. Whereas container management systems facilitate the deployment of cloud applications by employing container based artifacts, parts of the deployment logic have been applied before to build these artifacts. Current approaches do not integrate these two deployment phases in a comprehensive manner. Limited knowledge on application software and middleware encapsulated in container-based artifacts leads to maintainability and configuration issues. Besides, the deployment of cloud applications is based on custom orchestration solutions leading to lock in problems. In this paper, we propose a two-phase deployment method based on the TOSCA standard. We present integration concepts for TOSCA-based orchestration and deployment automation using container-based artifacts. Our two-phase deployment method enables capturing and aligning all the deployment logic related to a software release leading to better maintainability. Furthermore, we build a container management system, which is composed of a TOSCA-based orchestrator on Apache Mesos, to deploy container-based cloud applications automatically.
Public transport maps are typically designed in a way to support route finding tasks for passengers, while they also provide an overview about stations, metro lines, and city-specific attractions. Most of those maps are designed as a static representation, maybe placed in a metro station or printed in a travel guide. In this paper, we describe a dynamic, interactive public transport map visualization enhanced by additional views for the dynamic passenger data on different levels of temporal granularity. Moreover, we also allow extra statistical information in form of density plots, calendar-based visualizations, and line graphs. All this information is linked to the contextual metro map to give a viewer insights into the relations between time points and typical routes taken by the passengers. We also integrated a graph-based view on user-selected routes, a way to interactively compare those routes, an attribute- and property-driven automatic computation of specific routes for one map as well as for all available maps in our repertoire, and finally, also the most important sights in each city are included as extra information to include in a user-selected route. We illustrate the usefulness of our interactive visualization and map navigation system by applying it to the railway system of Hamburg in Germany while also taking into account the extra passenger data. As another indication for the usefulness of the interactively enhanced metro maps we conducted a controlled user experiment with 20 participants.
In our initial DaMoN paper, we set out the goal to revisit the results of “Starring into the Abyss [...] of Concurrency Control with [1000] Cores” (Yu in Proc. VLDB Endow 8: 209-220, 2014). Against their assumption, today we do not see single-socket CPUs with 1000 cores. Instead, multi-socket hardware is prevalent today and in fact offers over 1000 cores. Hence, we evaluated concurrency control (CC) schemes on a real (Intel-based) multi-socket platform. To our surprise, we made interesting findings opposing results of the original analysis that we discussed in our initial DaMoN paper. In this paper, we further broaden our analysis, detailing the effect of hardware and workload characteristics via additional real hardware platforms (IBM Power8 and 9) and the full TPC-C transaction mix. Among others, we identified clear connections between the performance of the CC schemes and hardware characteristics, especially concerning NUMA and CPU cache. Overall, we conclude that no CC scheme can efficiently make use of large multi-socket hardware in a robust manner and suggest several directions on how CC schemes and overall OLTP DBMS should evolve in future.
Background
Personalized medicine requires the integration and analysis of vast amounts of patient data to realize individualized care. With Surgomics, we aim to facilitate personalized therapy recommendations in surgery by integration of intraoperative surgical data and their analysis with machine learning methods to leverage the potential of this data in analogy to Radiomics and Genomics.
Methods
We defined Surgomics as the entirety of surgomic features that are process characteristics of a surgical procedure automatically derived from multimodal intraoperative data to quantify processes in the operating room. In a multidisciplinary team we discussed potential data sources like endoscopic videos, vital sign monitoring, medical devices and instruments and respective surgomic features. Subsequently, an online questionnaire was sent to experts from surgery and (computer) science at multiple centers for rating the features’ clinical relevance and technical feasibility.
Results
In total, 52 surgomic features were identified and assigned to eight feature categories. Based on the expert survey (n = 66 participants) the feature category with the highest clinical relevance as rated by surgeons was “surgical skill and quality of performance” for morbidity and mortality (9.0 ± 1.3 on a numerical rating scale from 1 to 10) as well as for long-term (oncological) outcome (8.2 ± 1.8). The feature category with the highest feasibility to be automatically extracted as rated by (computer) scientists was “Instrument” (8.5 ± 1.7). Among the surgomic features ranked as most relevant in their respective category were “intraoperative adverse events”, “action performed with instruments”, “vital sign monitoring”, and “difficulty of surgery”.
Conclusion
Surgomics is a promising concept for the analysis of intraoperative data. Surgomics may be used together with preoperative features from clinical data and Radiomics to predict postoperative morbidity, mortality and long-term outcome, as well as to provide tailored feedback for surgeons.
Stent graft visualization and planning tool for endovascular surgery using finite element analysis
(2014)
Purpose: A new approach to optimize stent graft selection for endovascular aortic repair is the use of finite element analysis. Once the finite element model is created and solved, a software module is needed to view the simulation results in the clinical work environment. A new tool for Interpretation of simulation results, named Medical Postprocessor, that enables comparison of different stent graft configurations and products was designed, implemented and tested. Methods Aortic endovascular stent graft ring forces and sealing states in the vessel landing zone of three different configurations were provided in a surgical planning software using the Medical Imaging Interaction Tool Kit (MITK) Software system. For data interpretation, software modules for 2D and 3D presentations were implemented. Ten surgeons evaluated the software features of the Medical Postprocessor. These surgeons performed usability tests and answered questionnaires based on their experience with the system.
Results: The Medical Postprocessor visualization system enabled vascular surgeons to determine the configuration with the highest overall fixation force in 16 ± 6 s, best proximal sealing in 56±24 s and highest proximal fixation force in 38 ± 12 s. The majority considered the multiformat data provided helpful and found the Medical Postprocessor to be an efficient decision support system for stent graft selection. The evaluation of the user interface results in an ISONORMconform user interface (113.5 points).
Conclusion: The Medical Postprocessor visualization Software tool for analyzing stent graft properties was evaluated by vascular surgeons. The results show that the software can assist the interpretation of simulation results to optimize stent graft configuration and sizing.
One of the key challenges for automatic assistance is the support of actors in the operating room depending on the status of the procedure. Therefore, context information collected in the operating room is used to gain knowledge about the current situation. In literature, solutions already exist for specific use cases, but it is doubtful to what extent these approaches can be transferred to other conditions. We conducted a comprehensive literature research on existing situation recognition systems for the intraoperative area, covering 274 articles and 95 cross-references published between 2010 and 2019. We contrasted and compared 58 identified approaches based on defined aspects such as used sensor data or application area. In addition, we discussed applicability and transferability. Most of the papers focus on video data for recognizing situations within laparoscopic and cataract surgeries. Not all of the approaches can be used online for real-time recognition. Using different methods, good results with recognition accuracies above 90% could be achieved. Overall, transferability is less addressed. The applicability of approaches to other circumstances seems to be possible to a limited extent. Future research should place a stronger focus on adaptability. The literature review shows differences within existing approaches for situation recognition and outlines research trends. Applicability and transferability to other conditions are less addressed in current work.