Informatik
Refine
Document Type
Language
- English (25) (remove)
Has full text
- yes (25)
Is part of the Bibliography
- yes (25)
Institute
- Informatik (25)
Publisher
- Hochschule Reutlingen (25) (remove)
Sleep analysis using a Polysomnography system is difficult and expensive. That is why we suggest a non-invasive and unobtrusive measurement. Very few people want the cables or devices attached to their bodies during sleep. The proposed approach is to implement a monitoring system, so the subject is not bothered. As a result, the idea is a non-invasive monitoring system based on detecting pressure distribution. This system should be able to measure the pressure differences that occur during a single heartbeat and during breathing through the mattress. The system consists of two blocks signal acquisition and signal processing. This whole technology should be economical to be affordable enough for every user. As a result, preprocessed data is obtained for further detailed analysis using different filters for heartbeat and respiration detection. In the initial stage of filtration, Butterworth filters are used.
This paper investigates the possibility to effectively monitor and control the respiratory action using a very simple and non invasive technique based on a single lightweight reduced-size wireless surface electromyography (sEMG) sensor placed below the sternum. The captured sEMG signal, due to the critical sensor position, is characterized by a low energy level and it is affected by motion artifacts and cardiac noise. In this work we present a preliminary study performed on adults for assessing the correlation of the spirometry signal and the sEMG signal after the removal of the superimposed heart signal. This study and the related findings could be useful in respiratory monitoring of preterm infants.
Determination of accelerometer sensor position for respiration rate detection: initial research
(2022)
Continuous monitoring of a patient's vital signs is essential in many chronic illnesses. The respiratory rate (RR) is one of the vital signs indicating breathing diseases. This article proposes the initial investigation for determining the accelerometric sensor position of a non-invasive and unobtrusive respiratory rate monitoring system. This research aims to determine the sensor position in relation to the patient, which can provide the most accurate values of the mentioned physiological parameter. In order to achieve the result, the particular system setup, including a mechanical sensor holder construction was used. The breathing signals from 5 participants were analyzed corresponding to the relaxed state. The main criterion for selecting a suitable sensor position was each patient's average acceleration amplitude excursion, which corresponds to the respiratory signal. As a result, we provided one more defined important parameter for the considered system, which was not determined before.
Semi-automated image data labelling using AprilTags as a pre-processing step for machine learning
(2019)
Data labelling is a pre-processing step to prepare data for machine learning. There are many ways to collect and prepare this data, but these are usually associated with a greater effort. This paper presents an approach to semi-automated image data labelling using AprilTags. The AprilTags attached to the object, which contain a unique ID, make it possible to link the object surfaces to a particular class. This approach will be implemented and used to label data of a stackable box.
The data is evaluated by training a You Only Look Once (YOLO) net, with a subsequent evaluation of the detection results. These results show that the semi-automatically collected and labelled data can certainly be used for machine learning. However, if concise features of an object surface are covered by the AprilTag, there is a risk that the concerned class will not be recognized. It can be assumed that the labelled data can not only be used for YOLO, but also for other machine learning approaches.
Strategy to test mobile apps
(2014)
Nowadays the development of a mobile app implies challenges and difficulties, which have to be faced by mobile app developers. Innovations lead to a rapidly evolving mobile app market, therefore apps should be developed faster and offered in short release cycles to the market. Testing is a decisive activity within the development process that helps to improve the quality of the app. This research paper describes a strategy to test mobile apps that overcomes the challenges that mobile apps confront and permits to test the app in a structural test environment.
Detecting semantic similarities between sentences is still a challenge today due to the ambiguity of natural languages. In this work, we propose a simple approach to identifying semantically similar questions by combining the strengths of word embeddings and Convolutional Neural Networks (CNNs). In addition, we demonstrate how the cosine similarity metric can be used to effectively compare feature vectors. Our network is trained on the Quora dataset, which contains over 400k question pairs. We experiment with different embedding approaches such as Word2Vec, Fasttext, and Doc2Vec and investigate the effects these approaches have on model performance. Our model achieves competitive results on the Quora dataset and complements the well-established evidence that CNNs can be utilized for paraphrase recognition tasks.
The importance of sleep for human life is enormous. It affects physical, mental, and psychological health. Therefore, it is vital to recognise sleep disorders in a timely manner in order to be able to initiate therapy. There are two methods for measuring sleep-related parameters - objective and subjective. Whether the substitution of a subjective method for an objective one is possible is investigated in this paper. Such replacement may bring several advantages, including increased comfort for the user. To answer this research question, a study was conducted in which 75 overnight recordings were evaluated. The primary purpose of this study was to compare both ways of measurement for total sleep time and sleep efficiency, which are essential parameters for, e.g., insomnia diagnosis and treatment. The evaluation results demonstrated that, on average, there are 32 minutes of difference between the two measurement methods when total sleep time is analysed. In contrast, on average, both measurement methods differ by 7.5% for sleep efficiency measurement. It should also be noted that people typically overestimate total sleep time and efficiency with the subjective method, where the perceived values are measured.
Sleep is essential to existence, much like air, water, and food, as we spend nearly one-third of our time sleeping. Poor sleep quality or disturbed sleep causes daytime solemnity, which worsens daytime activities' mental and physical qualities and raises the risk of accidents. With advancements in sensor and communication technology, sleep monitoring is moving out of specialized clinics and into our everyday homes. It is possible to extract data from traditional overnight polysomnographic recordings using more basic tools and straightforward techniques. Ballistocardiogram is an unobtrusive, non-invasive, simple, and low-cost technique for measuring cardiorespiratory parameters. In this work, we present a sensor board interface to facilitate the communication between force sensitive resistor sensor and an embedded system to provide a high-performing prototype with an efficient signal-to-noise ratio. We have utilized a multi-physical-layer approach to locate each layer on top of another, yet supporting a low-cost, compact design with easy deployment under the bed frame.
Integrating tools and applications into a clinically useful system for individual continuous health data surveillance requires an architecture considering all relevant medical and technical conditions. Therefore, the requirements of an integrated system including a health app to collect and monitor sensor data to support personalized medicine are analyzed. The structure and behavior of the system are defined regarding the specific health use cases and scenarios. A vendor-independent architecture, which enables the collection of vital data from arbitrary wearables using a smartphone, is presented. The data is centrally managed and processed by attending physicians. The modular architecture allows the system to extend to new scenarios, data formats, etc. A prototypical implementation of the system shows the feasibility of the approach.
A clinically useful system for individual continuous health data monitoring needs an architecture that takes into account all relevant medical and technical conditions. The requirements for a health app to support such a system are collected, and a vendor independent architecture is designed that allows the collection of vital data from arbitrary wearables using a smartphone. A prototypical implementation for the main scenario shows the feasibility of the approach.
Generating synthetic data is a relevant point in the machine learning community. As accessible data is limited, the generation of synthetic data is a significant point in protecting patients' privacy and having more possibilities to train a model for classification or other machine learning tasks. In this work, some generative adversarial networks (GAN) variants are discussed, and an overview is given of how generative adversarial networks can be used for data generation in different fields. In addition, some common problems of the GANs and possibilities to avoid them are shown. Different evaluation methods of the generated data are also described.
Due to the rising need for palliative care in Russia, it is crucial to provide timely and high-quality solutions for patients, relatives, and caregivers. A methodology for remote monitoring of patients in need of palliative care and the requirements will be developed for a hardware-software complex for remote monitoring of patients' health at home.
There are several intra-operative use cases which require the surgeon to interact with medical devices. I used the Leap Motion Controller as input device for three use-cases: 2D-interaction (e.g. advancing EPR data), selection of a value (e.g. room illumination brightness) and an application point and click scenario. I evaluated the Palm Mouse as the most suitable gesture solution to coordinate the mouse and advise to use the implementation using all fingers to perform a click. This small case study introduces the implementations and methods that result those recommendations.
The potentials and opportunities created by digitized healthcare can be further customized through smart data processing and analysis using accurate patient information. This development and the associated new treatment concepts basing on digital smart sensors can lead to an increase in motivation by applying gamification approaches. This effect can also be used in the field of medical treatment, e.g. with the help of a digital spirometer combined with an app. In one of our exemplary applications, we show how to control an airplane within an app by breathing respectively inhaling and exhaling. Using this biofeedback within a game allows us to increase the motivation and fun for children that need to perform necessary exercises.
Going forward with the requirements of missions to the Moon and further into deep space, the European Space Agency is investigating new methods of astronaut training that can help accelerate learning, increase availability and reduce complexity and cost in comparison to currently used methods. To achieve this, technologies such as virtual reality may be utilized. In this paper, an investigation into the benefits of using virtual reality as a means for extravehicular activity training in comparison to conventional training methods, such as neutral buoyancy pools is given. To help determine the requirements and current uses of virtual reality for extravehicular activity training first hand tests of currently available software as well as expert interviews are utilized. With this knowledge a concept is developed that may be used to further advance training methods in virtual reality. The resulting concept is used as a basis for development of a prototype to showcase user interactions and locomotion in microgravity simulations.
In summary, we believe that current “sleep monitoring” consumer devices on the market must undergo a more robust validation process before being made available and distributed in the general public. This is especially noteworthy as there have been first reports in the literature that inaccurate feedback of such consumer devices can worry subjects and may even lead to compromised well-being of the user.
The purpose of this paper is to examine the effects of perceived stress on traffic and road safety. One of the leading causes of stress among drivers is the feeling of having a lack of control during the driving process. Stress can result in more traffic accidents, an increase in driver errors, and an increase in traffic violations. To study this phenomenon, the Stress Perceived Questionnaire (PSQ) was used to evaluate the perceived stress while driving in a simulation. The study was conducted with participants from Germany, and they were grouped into different categories based on their emotional stability. Each participant was monitored using wearable devices that measured their instantaneous heart rate (HR). The preference for wearable devices was due to their non-intrusive and portable nature. The results of this study provide an overview of how stress can affect traffic and road safety, which can be used for future research or to implement strategies to reduce road accidents and promote traffic safety.
Assistive environments are entering our homes faster than ever. However, there are still various barriers to be broken. One of the crucial points is a personalization of offered services and integration of assistive technologies in common objects and therefore in a regular daily routine. Recognition of sleep patterns for the preliminary sleep study is one of the Health services that could be performed in an undisturbing way. This article proposes the hardware system for the measurement of bio-vital signals necessary for initial sleep study in a nonobtrusive way. The first results confirm the potential of measurement of breathing and movement signals with the proposed system.
Today many scientific works are using deep learning algorithms and time series, which can detect physiological events of interest. In sleep medicine, this is particularly relevant in detecting sleep apnea, specifically in detecting obstructive sleep apnea events. Deep learning algorithms with different architectures are used to achieve decent results in accuracy, sensitivity, etc. Although there are models that can reliably determine apnea and hypopnea events, another essential aspect to consider is the explainability of these models, i.e., why a model makes a particular decision. Another critical factor is how these deep learning models determine how severe obstructive sleep apnea is in patients based on the apnea-hypopnea index (AHI). Deep learning models trained by two approaches for AHI determination are exposed in this work. Approaches vary depending on the data format the models are fed: full-time series and window-based time series.