Informatik
Refine
Document Type
- Conference proceeding (498)
- Journal article (186)
- Book chapter (48)
- Doctoral Thesis (10)
- Book (3)
- Report (1)
- Working Paper (1)
Has full text
- yes (747) (remove)
Is part of the Bibliography
- yes (747)
Institute
- Informatik (747)
- Technik (2)
Publisher
- Springer (160)
- Hochschule Reutlingen (95)
- IEEE (89)
- Gesellschaft für Informatik e.V (59)
- Elsevier (42)
- Association for Computing Machinery (37)
- IARIA (26)
- RWTH Aachen (14)
- De Gruyter (13)
- SciTePress (11)
While several service-based maintainability metrics have been proposed in the scientific literature, reliable approaches to automatically collect these metrics are lacking. Since static analysis is complicated for decentralized and technologically diverse microservice-based systems, we propose a dynamic approach to calculate such metrics from runtime data via distributed tracing. The approach focuses on simplicity, extensibility, and broad applicability. As a first prototype, we implemented a Java application with a Zipkin integrator, 23 different metrics, and five export formats. We demonstrated the feasibility of the approach by analyzing the runtime data of an example microservice based system. During an exploratory study with six participants, 14 of the 18 services were invoked via the system’s web interface. For these services, all metrics were calculated correctly from the generated traces.
Towards a practical maintainability quality model for service- and microservice-based systems
(2017)
Although current literature mentions a lot of different metrics related to the maintainability of service-based systems (SBSs), there is no comprehensive quality model (QM) with automatic evaluation and practical focus. To fill this gap, we propose a Maintainability Model for Services (MM4S), a layered maintainability QM consisting of service properties (SPs) related with automatically collectable Service Metrics (SMs). This research artifact created within an ongoing Design Science Research (DSR) project is the first version ready for detailed evaluation and critical feedback. The goal of MM4S is to serve as a simple and practical tool for basic maintainability estimation and control in the context of BSs and their specialization
microservice-based systems (μSBSs).
In a time of digital transformation, the ability to quickly and efficiently adapt software systems to changed business requirements becomes more important than ever. Measuring the maintainability of software is therefore crucial for the long-term management of such products. With service-based systems (SBSs) being a very important form of enterprise software, we present a holistic overview of such metrics specifically designed for this type of system, since traditional metrics – e.g. object oriented ones – are not fully applicable in this case. The selected metric candidates from the literature review were mapped to 4 dominant design properties: size, complexity, coupling, and cohesion. Microservice-based systems (μSBSs) emerge as an agile and fine grained variant of SBSs. While the majority of identified metrics are also applicable to this specialization (with some limitations), the large number of services in combination with technological heterogeneity and decentralization of control significantly impacts automatic metric collection in such a system. Our research therefore suggests that specialized tool support is required to guarantee the practical applicability of the presented metrics to μSBSs.
Software evolvability is an important quality attribute, yet one difficult to grasp. A certain base level of it is allegedly provided by service- and microservice-based systems, but many software professionals lack systematic understanding of the reasons and preconditions for this. We address this issue via the proxy of architectural modifiability tactics. By qualitatively mapping principles and patterns of Service Oriented Architecture (SOA) and microservices onto tactics and analyzing the results, we cannot only generate insights into service-oriented evolution qualities, but can also provide a modifiability comparison of the two popular service-based architectural styles. The results suggest that both SOA and microservices possess several inherent qualities beneficial for software evolution. While both focus strongly on loose coupling and encapsulation, there are also differences in the way they strive for modifiability (e.g. governance vs. evolutionary design). To leverage the insights of this research, however, it is necessary to find practical ways to incorporate the results as guidance into the software development process.
Background: Design patterns are supposed to improve various quality attributes of software systems. However, there is controversial quantitative evidence of this impact. Especially for younger paradigms such as service- and microservice-based systems, there is a lack of empirical studies.
Objective: In this study, we focused on the effect of four service-based patterns - namely process abstraction, service façade, decomposed capability, and event-driven messaging - on the evolvability of a system from the viewpoint of inexperienced developers.
Method: We conducted a controlled experiment with Bachelor students (N = 69). Two functionally equivalent versions of a service-based web shop - one with patterns (treatment group), one without (control group) - had to be changed and extended in three tasks. We measured evolvability by the effectiveness and efficiency of the participants in these tasks. Additionally, we compared both system versions with nine structural maintainability metrics for size, granularity, complexity, cohesion, and coupling.
Results: Both experiment groups were able to complete a similar number of tasks within the allowed 90 min. Median effectiveness was 1/3. Mean efficiency was 12% higher in the treatment group, but this difference was not statistically significant. Only for the third task, we found statistical support for accepting the alternative hypothesis that the pattern version led to higher efficiency. In the metric analysis, the pattern version had worse measurements for size and granularity while simultaneously having slightly better values for coupling metrics. Complexity and cohesion were not impacted.
Interpretation: For the experiment, our analysis suggests that the difference in efficiency is stronger with more experienced participants and increased from task to task. With respect to the metrics, the patterns introduce additional volume in the system, but also seem to decrease coupling in some areas.
Conclusions: Overall, there was no clear evidence for a decisive positive effect of using service-based patterns, neither for the student experiment nor for the metric analysis. This effect might only be visible in an experiment setting with higher initial effort to understand the system or with more experienced developers.
While many maintainability metrics have been explicitly designed for service-based systems, tool-supported approaches to automatically collect these metrics are lacking. Especially in the context of microservices, decentralization and technological heterogeneity may pose challenges for static analysis. We therefore propose the modular and extensible RAMA approach (RESTful API Metric Analyzer) to calculate such metrics from machine-readable interface descriptions of RESTful services. We also provide prototypical tool support, the RAMA CLI, which currently parses the formats OpenAPI, RAML, and WADL and calculates 10 structural service-based metrics proposed in scientific literature. To make RAMA measurement results more actionable, we additionally designed a repeatable benchmark for quartile-based threshold ranges (green, yellow, orange, red). In an exemplary run, we derived thresholds for all RAMA CLI metrics from the interface descriptions of 1,737 publicly available RESTful APIs. Researchers and practitioners can use RAMA to evaluate the maintainability of RESTful services or to support the empirical evaluation of new service interface metrics.
Scenario-based analysis is a comprehensive technique to evaluate software quality and can provide more detailed insights than e.g. maintainability metrics. Since such methods typically require significant manual effort, we designed a lightweight scenario-based evolvability evaluation method. To increase efficiency and to limit assumptions, the method exclusively targets service- and microservice-based systems. Additionally, we implemented web-based tool support for each step. Method and tool were also evaluated with a survey (N=40) that focused on change effort estimation techniques and hands-on interviews (N=7) that focused on usability. Based on the evaluation results, we improved method and tool support further. To increase reuse and transparency, the web-based application as well as all survey and interview artifacts are publicly available on GitHub. In its current state, the tool-supported method is ready for first industry case studies.
IT environments that consist of a very large number of rather small structures like microservices, Internet of Things (IoT) components, or mobility systems are emerging to support flexible and agile products and services in the age of digital transformation. Biological metaphors of living and adaptable ecosystems with service-oriented enterprise architectures provide the foundation for self-optimizing, resilient run-time environments and distributed information systems. We are extending Enterprise Architecture (EA) methodologies and models that cover a high degree of heterogeneity and distribution to support the digital transformation and related information systems with micro-granular architectures. Our aim is to support flexibility and agile transformation for both IT and business capabilities within adaptable digital enterprise architectures. The present research paper investigates mechanisms for integrating Microservice Architectures (MSA) by extending original enterprise architecture reference models with elements for more flexible architectural metamodels and EA-mini-descriptions.
The fast moving process of digitization1 demands flexibility in order to adapt to rapidly changing business requirements and newly emerging business opportunities. New features have to be developed and deployed to the production environment a lot faster. To be able to cope with this increased velocity and pressure, a lot of software developing companies have switched to a Microservice Architecture (MSA) approach. Applications built this way consist of several fine-grained and heterogeneous services that are independently scalable and deployable. However, the technological and business architectural impacts of microservices based applications directly affect their integration into the digital enterprise architecture. As a consequence, traditional Enterprise Architecture Management (EAM) approaches are not able to handle the extreme distribution, diversity, and volatility of micro-granular systems and services. We are therefore researching mechanisms for dynamically integrating large amounts of microservices into an adaptable digital enterprise architecture.
To bring a pattern-based perspective to the SOA vs. microservices discussion, we qualitatively analyzed a total of 118 SOA patterns from 2 popular catalogs for their (partial) applicability to microservices. Patterns had to hold up to 5 derived microservices principles to be applicable. 74 patterns (63%) were categorized as fully applicable, 30 (25%) as partially applicable, and 14 (12%) as not applicable. Most frequently violated microservices characteristics werde Decentralization and Single System. The findings suggest that microservices and SOA share a large set of architectural principles and solutions in the general space of service-based systems while only having a small set of differences in specific areas.
Evaluation of a contactless accelerometer sensor system for heart rate monitoring during sleep
(2024)
The monitoring of a patient's heart rate (HR) is critical in the diagnosis of diseases. In the detection of sleep disorders, it also plays an important role. Several techniques have been proposed, including using sensors to record physiological signals that are automatically examined and analysed. This work aims to evaluate using a contactless HR monitoring system based on an accelerometer sensor during sleep. For this purpose, the oscillations caused by chest movements during heart contractions are recorded by an installation mounted under the bed mattress. The processing algorithm presented in this paper filters the signals and determines the HR. As a result, an average error of about 5 bpm has been documented, i.e., the system can be considered to be used for the forecasted domain.
Sleep is extremely important for physical and mental health. Although polysomnography is an established approach in sleep analysis, it is quite intrusive and expensive. Consequently, developing a non-invasive and non-intrusive home sleep monitoring system with minimal influence on patients, that can reliably and accurately measure cardiorespiratory parameters, is of great interest. The aim of this study is to validate a non-invasive and unobtrusive cardiorespiratory parameter monitoring system based on an accelerometer sensor. This system includes a special holder to install the system under the bed mattress. The additional aim is to determine the optimum relative system position (in relation to the subject) at which the most accurate and precise values of measured parameters could be achieved. The data were collected from 23 subjects (13 males and 10 females). The obtained ballistocardiogram signal was sequentially processed using a sixth-order Butterworth bandpass filter and a moving average filter. As a result, an average error (compared to reference values) of 2.24 beats per minute for heart rate and 1.52 breaths per minute for respiratory rate was achieved, regardless of the subject’s sleep position. For males and females, the errors were 2.28 bpm and 2.19 bpm for heart rate and 1.41 rpm and 1.30 rpm for respiratory rate. We determined that placing the sensor and system at chest level is the preferred configuration for cardiorespiratory measurement. Further studies of the system’s performance in larger groups of subjects are required, despite the promising results of the current tests in healthy subjects.
Sleep is an essential part of human existence, as we are in this state for approximately a third of our lives. Sleep disorders are common conditions that can affect many aspects of life. Sleep disorders are diagnosed in special laboratories with a polysomnography system, a costly procedure requiring much effort for the patient. Several systems have been proposed to address this situation, including performing the examination and analysis at the patient's home, using sensors to detect physiological signals automatically analysed by algorithms. This work aims to evaluate the use of a contactless respiratory recording system based on an accelerometer sensor in sleep apnea detection. For this purpose, an installation mounted under the bed mattress records the oscillations caused by the chest movements during the breathing process. The presented processing algorithm performs filtering of the obtained signals and determines the apnea events presence. The performance of the developed system and algorithm of apnea event detection (average values of accuracy, specificity and sensitivity are 94.6%, 95.3%, and 93.7% respectively) confirms the suitability of the proposed method and system for further ambulatory and in-home use.
Sleep is essential to physical and mental health. However, the traditional approach to sleep analysis—polysomnography (PSG)—is intrusive and expensive. Therefore, there is great interest in the development of non-contact, non-invasive, and non-intrusive sleep monitoring systems and technologies that can reliably and accurately measure cardiorespiratory parameters with minimal impact on the patient. This has led to the development of other relevant approaches, which are characterised, for example, by the fact that they allow greater freedom of movement and do not require direct contact with the body, i.e., they are non-contact. This systematic review discusses the relevant methods and technologies for non-contact monitoring of cardiorespiratory activity during sleep. Taking into account the current state of the art in non-intrusive technologies, we can identify the methods of non-intrusive monitoring of cardiac and respiratory activity, the technologies and types of sensors used, and the possible physiological parameters available for analysis. To do this, we conducted a literature review and summarised current research on the use of non-contact technologies for non-intrusive monitoring of cardiac and respiratory activity. The inclusion and exclusion criteria for the selection of publications were established prior to the start of the search. Publications were assessed using one main question and several specific questions. We obtained 3774 unique articles from four literature databases (Web of Science, IEEE Xplore, PubMed, and Scopus) and checked them for relevance, resulting in 54 articles that were analysed in a structured way using terminology. The result was 15 different types of sensors and devices (e.g., radar, temperature sensors, motion sensors, cameras) that can be installed in hospital wards and departments or in the environment. The ability to detect heart rate, respiratory rate, and sleep disorders such as apnoea was among the characteristics examined to investigate the overall effectiveness of the systems and technologies considered for cardiorespiratory monitoring. In addition, the advantages and disadvantages of the considered systems and technologies were identified by answering the identified research questions. The results obtained allow us to determine the current trends and the vector of development of medical technologies in sleep medicine for future researchers and research.
Determination of accelerometer sensor position for respiration rate detection: initial research
(2022)
Continuous monitoring of a patient's vital signs is essential in many chronic illnesses. The respiratory rate (RR) is one of the vital signs indicating breathing diseases. This article proposes the initial investigation for determining the accelerometric sensor position of a non-invasive and unobtrusive respiratory rate monitoring system. This research aims to determine the sensor position in relation to the patient, which can provide the most accurate values of the mentioned physiological parameter. In order to achieve the result, the particular system setup, including a mechanical sensor holder construction was used. The breathing signals from 5 participants were analyzed corresponding to the relaxed state. The main criterion for selecting a suitable sensor position was each patient's average acceleration amplitude excursion, which corresponds to the respiratory signal. As a result, we provided one more defined important parameter for the considered system, which was not determined before.
The respiratory rate is a vital sign indicating breathing illness. It is necessary to analyze the mechanical oscillations of the patient's body arising from chest movements. An inappropriate holder on which the sensor is mounted, or an inappropriate sensor position is some of the external factors which should be minimized during signal registration. This paper considers using a non-invasive device placed under the bed mattress and evaluates the respiratory rate. The aim of the work is the development of an accelerometer sensor holder for this system. The normal and deep breathing signals were analyzed, corresponding to the relaxed state and when taking deep breaths. The evaluation criterion for the holder's model is its influence on the patient's respiratory signal amplitude for each state. As a result, we offer a non-invasive system of respiratory rate detection, including the mechanical component providing the most accurate values of mentioned respiratory rate.
Das Provisioning Tool automaIT wurde prototypisch um die Möglichkeit eines Data Discovery erweitert, mit dem Ziel, nicht durch automaIT verwaltete Systeme anbinden und steuern zu können. Daten aus dem Data Discovery werden mittels dem Tool Facter gesammelt und können dynamisch in ausführbare Modelle von automaIT integriert und ausgewertet werden. Dadurch kann der Verlauf weiterer Provisionierungsschritte gesteuert werden, ohne dass es eines manuellen Eingriffs bedarf.
Distraction of the driver is one of the most frequent causes for car accidents. We aim for a computational cognitive model predicting the driver’s degree of distraction during driving while performing a secondary task, such as talking with co-passengers. The secondary task might cognitively involve the driver to differing degrees depending on the topic of the conversation or the number of co-passengers. In order to detect these subtle differences in everyday driving situations, we aim to analyse in-car audio signals and combine this information with head pose and face tracking information. In the first step, we will assess driving, video and audio parameters reliably predicting cognitive distraction of the driver. These parameters will be used to train the cognitive model in estimating the degree of the driver’s distraction. In the second step, we will train and test the cognitive model during conversations of the driver with co-passengers during active driving. This paper describes the work in progress of our first experiment with preliminary results concerning driving parameters corresponding to the driver’s degree of distraction. In addition, the technical implementation of our experiment combining driving, video and audio data and first methodological results concerning the auditory analysis will be presented. The overall aim for the application of the cognitive distraction model is the development of a mobile user profile computing the individual distraction degree and being applicable also to other systems.
Converting users into customers : the role of user profile information and customer journey analysis
(2016)
Due to the digital transformation, the importance of web analysis and user profiling for enterprises is increasing rapidly as customers focus on digital channels to obtain information about products and brands. While there exists a lot research on these topics, only a minority of firms use them to their advantage. This study aims to tighten the link between research and business such that experimental methods can be used for the improvement of communication strategies in practice. Therefore, a systematic literature analysis is conducted, workshops are observed and documented and an empirical study is used to integrate single steps into a framework for the
practical usage of user profiling and customer journey analysis.
Literature reviews are essential for any scientific work, both as part of a dissertation or as a stand-alone work. Scientists benefit from the fact that more and more literature is available in electronic form, and finding and accessing relevant literature has become more accessible through scientific databases. However, a traditional literature review method is characterized by a highly manual process, while technologies and methods in big data, machine learning, and text mining have advanced. Especially in areas where research streams are rapidly evolving, and topics are becoming more comprehensive, complex, and heterogeneous, it is challenging to provide a holistic overview and identify research gaps manually. Therefore, we have developed a framework that supports the traditional approach of conducting a literature review using machine learning and text mining methods. The framework is particularly suitable in cases where a large amount of literature is available, and a holistic understanding of the research area is needed. The framework consists of several steps in which the critical mind of the scientist is supported by machine learning. The unstructured text data is transformed into a structured form through data preparation realized with text mining, making it applicable for various machine learning techniques. A concrete example in the field of smart cities makes the framework tangible.