In recent years, artificial intelligence (AI) has increasingly become a relevant technology for many companies. While there are a number of studies that highlight challenges and success factors in the adoption of AI, there is a lack of guidance for firms on how to approach the topic in a holistic and strategic way. The aim of this study is therefore to develop a conceptual framework for corporate AI strategy. To address this aim, a systematic literature review of a wide spectrum of AI-related research is conducted, and the results are analyzed based on an inductive coding approach. An important conclusion is that companies should consider diverse aspects when formulating an AI strategy, ranging from technological questions to corporate culture and human resources. This study contributes to knowledge by proposing a novel, comprehensive framework to foster the understanding of crucial aspects that need to be considered when using the emerging technology of AI in a corporate context.
The rapid development and growth of knowledge has resulted in a rich stream of literature on various topics. Information systems (IS) research is becoming increasingly extensive, complex, and heterogeneous. Therefore, a proper understanding and timely analysis of the existing body of knowledge are important to identify emerging topics and research gaps. Despite the advances of information technology in the context of big data, machine learning, and text mining, the implementation of systematic literature reviews (SLRs) is in most cases still a purely manual task. This might lead to serious shortcomings of SLRs in terms of quality and time. The outlined approach in this paper supports the process of SLRs with machine learning techniques. For this purpose, we develop a framework with embedded steps of text mining, cluster analysis, and network analysis to analyze and structure a large amount of research literature. Although the framework is presented using IS research as an example, it is not limited to the IS field but can also be applied to other research areas.
Purpose
Supporting the surgeon during surgery is one of the main goals of intelligent ORs. The OR-Pad project aims to optimize the information flow within the perioperative area. A shared information space should enable appropriate preparation and provision of relevant information at any time before, during, and after surgery.
Methods
Based on previous work on an interaction concept and system architecture for the sterile OR-Pad system, we designed a user interface for mobile and intraoperative (stationary) use, focusing on the most important functionalities like clear information provision to reduce information overload. The concepts were transferred into a high-fidelity prototype for demonstration purposes. The prototype was evaluated from different perspectives, including a usability study.
Results
The prototype’s central element is a timeline displaying all available case information chronologically, like radiological images, labor findings, or notes. This information space can be adapted for individual purposes (e.g., highlighting a tumor, filtering for own material). With the mobile and intraoperative mode of the system, relevant information can be added, preselected, viewed, and extended during the perioperative process. Overall, the evaluation showed good results and confirmed the vision of the information system.
Conclusion
The high-fidelity prototype of the information system OR-Pad focuses on supporting the surgeon via a timeline making all available case information accessible before, during, and after surgery. The information space can be personalized to enable targeted support. Further development is reasonable to optimize the approach and address missing or insufficient aspects, like the holding arm and sterility concept or new desired features.
A hybrid deep registration of MR scans to interventional ultrasound for neurosurgical guidance
(2021)
Despite the recent advances in image-guided neurosurgery, reliable and accurate estimation of the brain shift still remains one of the key challenges. In this paper, we propose an automated multimodal deformable registration method using hybrid learning-based and classical approaches to improve neurosurgical procedures. Initially, the moving and fixed images are aligned using classical affine transformation (MINC toolkit), and then the result is provided to the convolutional neural network, which predicts the deformation field using backpropagation. Subsequently, the moving image is transformed using the resultant deformation into a moved image. Our model was evaluated on two publicly available datasets: the retrospective evaluation of cerebral tumors (RESECT) and brain images of tumors for evaluation (BITE). The mean target registration errors have been reduced from 5.35 ± 4.29 to 0.99 ± 0.22 mm in the RESECT and from 4.18 ± 1.91 to 1.68 ± 0.65 mm in the BITE. Experimental results showed that our method improved the state-of-the-art in terms of both accuracy and runtime speed (170 ms on average). Hence, the proposed method provides a fast runtime for 3D MRI to intra-operative US pair in a GPU-based implementation, which shows a promise for its applicability in assisting the neurosurgical procedures compensating for brain shift.
Data governance have been relevant for companies for a long time. Yet, in the broad discussion on smart cities, research on data governance in particular is scant, even though data governance plays an essential role in an environment with multiple stakeholders, complex IT structures and heterogeneous processes. Indeed, not only can a city benefit from the existing body of knowledge on data governance, but it can also make the appropriate adjustments for its digital transformation. Therefore, this literature review aims to spark research on urban data governance by providing an initial perspective for future studies. It provides a comprehensive overview of data governance and the relevant facets embedded in this strand of research. Furthermore, it provides a fundamental basis for future research on the development of an urban data governance framework.
Enterprise Governance, Risk and Compliance (GRC) systems are key to managing risks threatening modern enterprises from many different angles. Key constituent to GRC systems is the definition of controls that are implemented on the different layers of an Enterprise Architecture (EA). As part of the compliance aspect of GRC, the effectiveness of these controls is assessed and reported to relevant management bodies within the enterprise. In this paper we present a metamodel which links controls to the affected elements of an EA and supplies a way of expressing associated assessment techniques and results. We complement the metamodel with an expository instantiation in a cockpit for control compliance applied in an international enterprise in the insurance industry.
Introduction
Despite its high accuracy, polysomnography (PSG) has several drawbacks for diagnosing obstructive sleep apnea (OSA). Consequently, multiple portable monitors (PMs) have been proposed.
Objective
This systematic review aims to investigate the current literature to analyze the sets of physiological parameters captured by a PM to select the minimum number of such physiological signals while maintaining accurate results in OSA detection.
Methods
Inclusion and exclusion criteria for the selection of publications were established prior to the search. The evaluation of the publications was made based on one central question and several specific questions.
Results
The abilities to detect hypopneas, sleep time, or awakenings were some of the features studied to investigate the full functionality of the PMs to select the most relevant set of physiological signals. Based on the physiological parameters collected (one to six), the PMs were classified into sets according to the level of evidence. The advantages and the disadvantages of each possible set of signals were explained by answering the research questions proposed in the methods.
Conclusions
The minimum number of physiological signals detected by PMs for the detection of OSA depends mainly on the purpose and context of the sleep study. The set of three physiological signals showed the best results in the detection of OSA.
Model-guided Therapy and Surgical Workflow Systems are two interrelated research fields, which have been developed separately in the last years. To make full use of both technologies, it is necessary to integrate them and connect them to Hospital Information Systems. We propose a framework for integration of Model-guided Therapy in Hospital Information Systems based on the Electronic Medical Record, and a taskbased Workflow Management System, which is suitable for clinical end users. Two prototypes - one based on Business Process Modeling Language, one based on the serum-board - are presented. From the experience with these prototypes, we developed a novel personalized visualization system for Surgical Workflows and Model-guided Therapy. Key challenges for further development are automated situation detection and a common communication infrastructure.
While several service-based maintainability metrics have been proposed in the scientific literature, reliable approaches to automatically collect these metrics are lacking. Since static analysis is complicated for decentralized and technologically diverse microservice-based systems, we propose a dynamic approach to calculate such metrics from runtime data via distributed tracing. The approach focuses on simplicity, extensibility, and broad applicability. As a first prototype, we implemented a Java application with a Zipkin integrator, 23 different metrics, and five export formats. We demonstrated the feasibility of the approach by analyzing the runtime data of an example microservice based system. During an exploratory study with six participants, 14 of the 18 services were invoked via the system’s web interface. For these services, all metrics were calculated correctly from the generated traces.
Purpose: This paper aims to conceptualize and empirically test the determinants of service interaction quality (SIQ) as attitude, behavior and expertise of a service provider (SP). Further, the individual and simultaneous effects of SIQ and its dimensions on important marketing outcomes are tested. Design/methodology/approach – The narrative review of extant research helps formulate a conceptual model of SIQ, which is investigated using the univariate and multivariate meta-analysis.
Findings: There are interdependencies between drivers of SIQ that underlines the need to conceptualize service interaction as a dyadic phenomenon; use contemporary multilevel models, dyadic models, non-linear structural equation modeling and process studies; and study new and diverse services contexts. Meta-analysis illustrates the relative importance of the three drivers of SIQ and, in turn, their impact on consumer satisfaction and loyalty.
Research limitations/implications – The meta-analysis is based on existing research, which, unfortunately, has not examined critical services or exigency situations where SIQ is of paramount importance. Future research will be tasked with diversifying to several important domains where SIQ is a critical aspect of perceived service quality.
Practical implications: This study emphasizes that, although the expertise of an SP is important, firms would be surprised to learn that the attitude and behavior of their employees are equally important antecedents. In fact, there is a delicate balance that needs to be found; otherwise, attitudinal factors can have an overall counterproductive effect on consumer satisfaction.
Originality/value: This paper provides an empirical synthesis of SIQ and opens up interesting areas for further research.
In this note we look at anisotropic approximation of smooth functions on bounded domains with tensor product splines. The main idea is to extend such functions and then use known approximation techniques on Rd. We prove an error estimate for domains for which bounded extension operators exist. This obvious approach has some limitations. It is not applicable without restrictions on the chosen coordinate degree even if the domain is as simple as the unit disk. Further for approximation on Rd there are error estimates in which the grid widths and directional derivatives are paired in an interesting way. It seems impossible to maintain this property using extension operators.
In the upcoming years, huge benefits are expected from Artificial Intelligence (AI). However, there are also risks involved in the technology, such as accidents of autonomous vehicles or discrimination by AI-based recruitment systems. This study aims to investigate public perception of these risks, focusing on realistic risks of Narrow AI, i.e., the type of AI that is already productive today. Based on perceived risk theory, several risk scenarios are examined using data from an exploratory survey. This research shows that AI is perceived positively overall. The participants, however, do evaluate AI critically when being confronted with specific risk scenarios. Furthermore, a strong positive relationship between knowledge about AI and perceived risk could be shown. This study contributes to knowledge by advancing our understanding of the awareness and evaluation of the risks by consumers and has important implications for product development, marketing and society.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.
Motivation
In order to enable context-aware behavior of surgical assistance systems, the acquisition of various information about the current intraoperative situation is crucial. To achieve this, the complex task of situation recognition can be delegated to a specialized system. Consequently, a standardized interface is required for the seamless transfer of the recognized contextual information to the assistance systems, enabling them to adapt accordingly.
Methods
Our group analyzed four medical interface standards to determine their suitability for exchanging intraoperative contextual information. The assessment was based on a harmonized data and service model derived from the requirements of expected context-aware use cases. The Digital Imaging and Communications in Medicine (DICOM) and IEEE 11073 for Service-oriented Device Connectivity (SDC) were identified as the most appropriate standards.
Results
We specified how DICOM Unified Procedure Steps (UPS), can be used to effectively communicate contextual information. We proposed the inclusion of attributes to formalize different granularity levels of the surgical workflow.
Conclusions
DICOM UPS SOP classes can be used for the exchange of intraoperative contextual information between a situation recognition system and surgical assistance systems. This can pave the way for vendor-independent context awareness in the OR, leading to targeted assistance of the surgical team and an improvement of the surgical workflow.
Documentation of clinical processes, especially in the perioperative are, is a base requirement for quality of service. Nonetheless, the documentation is a burden for the medical staff since it distracts from the clinical core process. An intuitive and user-friendly documentation system could increase documentation quality and reduce documentation workload. The optimal system solution would know what happened and the person documenting the step would need a single “confirm” button. In many cases, such a linear flow of activities is given as long as only one profession (e.g. anaestesiology, scrub nurse) is considered, but even in such cases, there might be derivations from the linear process flow and further interaction is required.
A lot of people need help in their daily life to wash, select and manage their clothing. The goal of this work is to design an assistant system (eKlarA) to support the user by giving recommendations to choose the clothing combinations, to find the clothing and to wash the clothing. The idea behind eKlarA is to generate a system that uses sensors to identify the clothing and their state in the clothing cycle. The clothing cycle consists of the stations: closets, laundry basket and washing machine in one or several places. The system uses the information about the clothing, weather and calendar to support the user in the different steps of the clothing cycle. The first prototype of this system has been developed and tested. The test results are presented in this work.
Sleep quality and in general, behavior in bed can be detected using a sleep state analysis. These results can help a subject to regulate sleep and recognize different sleeping disorders. In this work, a sensor grid for pressure and movement detection supporting sleep phase analysis is proposed. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this project is a non invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable actigraphy devices tends to be uncomfortable. Besides this fact, they are also very expensive. The system represented in this work classifies respiration and body movement with only one type of sensor and also in a non invasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed the potential for classification of breathing rate and body movements. Although previous researches show the use of pressure sensors in recognizing posture and breathing, they have been mostly used by positioning the sensors between the mattress and bedsheet. This project however, shows an innovative way to position the sensors under the mattress.
Background and purpose: Transapical aortic valve replacement (TAVR) is a recent minimally invasive surgical treatment technique for elderly and high-risk patients with severe aortic stenosis. In this paper,a simple and accurate image-based method is introduced to aid the intra-operative guidance of TAVR procedure under 2-D X-ray fluoroscopy.
Methods: The proposed method fuses a 3-D aortic mesh model and anatomical valve landmarks with live 2-D fluoroscopic images. The 3-D aortic mesh model and landmarks are reconstructed from interventional X-ray C-arm CT system, and a target area for valve implantation is automatically estimated using these aortic mesh models.Based on template-based tracking approach, the overlay of visualized 3-D aortic mesh model, land-marks and target area of implantation is updated onto fluoroscopic images by approximating the aortic root motion from a pigtail catheter motion without contrast agent. Also, a rigid intensity-based registration algorithm is used to track continuously the aortic root motion in the presence of contrast agent.Furthermore, a sensorless tracking of the aortic valve prosthesis is provided to guide the physician to perform the appropriate placement of prosthesis into the estimated target area of implantation.
Results: Retrospective experiments were carried out on fifteen patient datasets from the clinical routine of the TAVR. The maximum displacement errors were less than 2.0 mm for both the dynamic overlay of aortic mesh models and image-based tracking of the prosthesis, and within the clinically accepted ranges. Moreover, high success rates of the proposed method were obtained above 91.0% for all tested patient datasets.
Conclusion: The results showed that the proposed method for computer-aided TAVR is potentially a helpful tool for physicians by automatically defining the accurate placement position of the prosthesis during the surgical procedure.