Informatik
Refine
Document Type
- Conference proceeding (38)
- Journal article (37)
- Book chapter (5)
Has full text
- yes (80) (remove)
Is part of the Bibliography
- yes (80)
Institute
- Informatik (80)
- Technik (1)
Publisher
- Elsevier (21)
- Springer (19)
- Hochschule Reutlingen (10)
- IEEE (10)
- MDPI (8)
- Università Politecnica delle Marche (5)
- HTWG Konstanz (2)
- Association for Computing Machinery (1)
- Frontiers Research Foundation (1)
- JMIR Publications (1)
Stress is recognized as a factor of predominant disease and in the future the costs for treatment will increase. The presented approach tries to detect stress in a very basic and easy to implement way, so that the cost for the device and effort to wear it remain low. The user should benefit from the fact that the system offers an easy interface reporting the status of his body in real time. In parallel, the system provides interfaces to pass the obtained data forward for further processing and (professional) analyses, in case the user agrees. The system is designed to be used in every day’s activities and it is not restricted to laboratory use or environments. The implementation of the enhanced prototype shows that the detection of stress and the reporting can be managed using correlation plots and automatic pattern recognition even on a very light weighted microcontroller platform.
An ongoing challenge in our days is to lower the impact on the quality of life caused by dysfunctionality through individual support. With the background of an aging society and continuous increases in costs for care, a holistic solution is needed. This solution must integrate individual needs and preferences, locally available possibilities, regional conditions, professional and informal caregivers and provide the flexibility to implement future requirements. The proposed model is a result of a common initiative to overcome the major obstacles and to center a solution on individual needs caused by dysfunctionality.
The proposed approach applies current unsupervised clustering approaches in a different dynamic manner. Instead of taking all the data as input and finding clusters among them, the given approach clusters Holter ECG data (longterm electrocardiography data from a holter monitor) on a given interval which enables a dynamic clustering approach (DCA). Therefore advanced clustering techniques based on the well known Dynamic TimeWarping algorithm are used. Having clusters e.g. on a daily basis, clusters can be compared by defining cluster shape properties. Doing this gives a measure for variation in unsupervised cluster shapes and may reveal unknown changes in healthiness. Embedding this approach into wearable devices offers advantages over the current techniques. On the one hand users get feedback if their ECG data characteristic changes unforeseeable over time which makes early detection possible. On the other hand cluster properties like biggest or smallest cluster may help a doctor in making diagnoses or observing several patients. Further, on found clusters known processing techniques like stress detection or arrhythmia classification may be applied.
To evaluate the quality of a person´s sleep it is essential to identify the sleep stages and their durations. Currently, the gold standard in terms of sleep analysis is overnight polysomnography (PSG), during which several techniques like EEG (eletroencephalogram), EOG (electrooculogram), EMG (electromyogram), ECG (electrocardiogram), SpO2 (blood oxygen saturation) and for example respiratory airflow and respiratory effort are recorded. These expensive and complex procedures, applied in sleep laboratories, are invasive and unfamiliar for the subjects and it is a reason why it might have an impact on the recorded data. These are the main reasons why low-cost home diagnostic systems are likely to be advantageous. Their aim is to reach a larger population by reducing the number of parameters recorded. Nowadays, many wearable devices promise to measure sleep quality using only the ECG and body-movement signals. This work presents an android application developed in order to proof the accuracy of an algorithm published in the sleep literature. The algorithm uses ECG and body movement recordings to estimate sleep stages. The pre-recorded signals fed into the algorithm have been taken from physionet1 online database. The obtained results have been compared with those of the standard method used in PSG. The mean agreement ratios between the sleep stages REM, Wake, NREM-1, NREM-2 and NREM-3 were 38.1%, 14%, 16%, 75% and 54.3%.
Nowadays there is a rich diversity of sleep monitoring systems available on the market. They promise to offer information about sleep quality of the user by recording a limited number of vital signals, mainly heart rate and body movement. Typically, fitness trackers, smart watches, smart shirts, smartphone applications or patches do not provide access to the raw sensor data. Moreover, the sleep classification algorithm and the agreement ratio with the gold standard, polysomnography (PSG) are not disclosed. Some commercial systems record and store the data on the wearable device, but the user needs to transfer and import it into specialised software applications or return it to the doctor, for clinical evaluation of the data set. Thus an immediate feedback mechanism or the possibility of remote control and supervision are lacking. Furthermore, many such systems only distinguish between sleep and wake states, or between wake, light sleep and deep sleep. It is not always clear how these stages are mapped to the four known sleep stages: REM, NREM1, NREM2, NREM3-4. [1] The goal of this research is to find a reduced complexity method to process a minimum number of bio vital signals, while providing accurate sleep classification results. The model we propose offers remote control and real time supervision capabilities, by using Internet of Things (IoT) technology. This paper focuses on the data processing method and the sleep classification logic. The body sensor network representing our data acquisition system will be described in a separate publication. Our solution showed promising results and a good potential to overcome the limitations of existing products. Further improvements will be made and subjects with different age and health conditions will be tested.
Sleep is an important aspect in life of every human being. The average sleep duration for an adult is approximately 7 h per day. Sleep is necessary to regenerate physical and psychological state of a human. A bad sleep quality has a major impact on the health status and can lead to different diseases. In this paper an approach will be presented, which uses a long-term monitoring of vital data gathered by a body sensor during the day and the night supported by mobile application connected to an analyzing system, to estimate sleep quality of its user as well as give recommendations to improve it in real-time. Actimetry and historical data will be used to improve the individual recommendations, based on common techniques used in the area of machine learning and big data analysis.
Stress is becoming an important topic in modern life. The influence of stress results in a higher rate of health disorders such as burnout, heart problems, obesity, asthma, diabetes, depressions and many others. Furthermore individual’s behavior and capabilities could be directly affected leading to altered cognition, inappropriate decision making and problem solving skills. In a dynamic and unpredictable environment, such as automotive, this can result in a higher risk for accidents. Different papers faced the estimation as well as prediction of drivers’ stress level during driving. Another important question is not only the stress level of the driver himself, but also the influence on and of a group of other drivers in the near area. This paper proposes a system, which determines a group of drivers in a near area as clusters and it derives the individual stress level. This information will be analyzed to generate a stress map, which represents a graphical view about road section with a higher stress influence. Aggregated data can be used to generate navigation routes with a lower stress influence to decrease stress influenced driving as well as improve road safety.
Stress is recognized as a predominant disease with raising costs for rehabilitation and treatment. Currently there are several different approaches that can be used for determining and calculating the stress levels. Usually the methods for determining stress are divided in two categories. The first category do not require any special equipment for measuring the stress. This category useless the variation in the behaviour patterns that occur while stress. The core disadvantage for the category is their limitation to specific use case. The second category uses laboratories instruments and biological sensors. This category allow to measure stress precisely and proficiently but on the same time they are not mobile and transportable and do not support real-time feedback. This work presents a mobile system that provides the calculation of stress. For achieving this, the of a mobile ECG sensor is analysed, processed and visualised over a mobile system like a smartphone. This work also explains the used stress measurement algorithm. The result of this work is a portable system that can be used with a mobile system like a smartphone as visual interface for reporting the current stress level.
To evaluate the quality of sleep, it is important to determine how much time was spent in each sleep stage during the night. The gold standard in this domain is an overnight polysomnography (PSG). But the recording of the necessary electrophysiological signals is extensive and complex and the environment of the sleep laboratory, which is unfamiliar to the patient, might lead to distorted results. In this paper, a sleep stage detection algorithm is proposed that uses only the heart rate signal, derived from electrocardiogram (ECG), as a discriminator. This would make it possible for sleep analysis to be performed at home, saving a lot of effort and money. From the heart rate, using the fast Fourier transformation (FFT), three parameters were calculated in order to distinguish between the different sleep stages. ECG data along with a hypnogram scored by professionals was used from Physionet database, making it easy to compare the results. With an agreement rate of 41.3%, this approach is a good foundation for future research.
Sleep quality and in general, behavior in bed can be detected using a sleep state analysis. These results can help a subject to regulate sleep and recognize different sleeping disorders. In this work, a sensor grid for pressure and movement detection supporting sleep phase analysis is proposed. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this project is a non invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable actigraphy devices tends to be uncomfortable. Besides this fact, they are also very expensive. The system represented in this work classifies respiration and body movement with only one type of sensor and also in a non invasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed the potential for classification of breathing rate and body movements. Although previous researches show the use of pressure sensors in recognizing posture and breathing, they have been mostly used by positioning the sensors between the mattress and bedsheet. This project however, shows an innovative way to position the sensors under the mattress.
To assess the quality of a person’s sleep, it is essential to examine the sleep behaviour by identifying the several sleep stages, their durations and sleep cycles. The established and gold standard procedure for sleep stage scoring is overnight polysomnography (PSG) with the Rechtschaffen and Kales (R-K) method. Unfortunately, the conduct of PSG is time-consuming and unfamiliar for the subjects and might have an impact of the recorded data. To avoid the disadvantages with PSG, it is important to make further investigations in low-cost home diagnostic systems. For this intention it is necessary to find suitable bio vital parameters for classifying sleep stages without any physical impairments at the same time. Due to the promising results in several publications we want to analyse existing methods for sleep stage classification based on the parameters body movement,
heartbeat and respiration. Our aim was to find different behaviour patterns in the several sleep stages. Therefore, the average values of 15 whole-night PSG recordings -obtained from the ‘DREAMS
Subjects Database’- where analysed in the light of heartbeat, body movement and respiration with 10 different methods.
To analyze the humans’ sleep it is necessary as to identify the sleep stages, occurring during the sleep, their durations and sleep cycles. The gold standard procedure for this approach is polysomnography (PSG), which classify the sleep stages based on Rechtschaffen and Kales (R-K) method. This method aside the advantages as high accuracy has however some disadvantages, among others time-consuming and uncomfortable for the patient procedure. Therefore, the development of further methods for the sleep classification in addition to PSG is a promising topic for the investigation and this work has as its aim the presentation of possible ways and goals for this development.
A sleep study is a test used to diagnose sleep disorders and is usually done in sleep laboratories. The golden standard for evaluation of sleep is overnight polysomnography (PSG). Unfortunately, in-lab sleep studies are expensive and complex procedures. Furthermore, with a minimum of 22 wire attachments to the patient for sleep recording, this medical procedure is invasive and unfamiliar for the subjects. To solve this problem, low-cost home diagnostic systems, based on noninvasive recording methods requires further researches.
For this intention it is important to find suitable bio vital parameters for classifying sleep phases WAKE, REM, light sleep and deep sleep without any physical impairment at the same time. We decided to analyse body movement (BM), respiration rate (RR) and heart rate variability (HRV) from existing sleep recordings to develop an algorithm which is able to classify the sleep phases automatically. The preliminary results of this project show that BM, RR and HRV are suitable to identify WAKE, REM and NREM stage.
Sleep study can be used for detection of sleep quality and in general bed behaviors. These results can helpful for regulating sleep and recognizing different sleeping disorders of human. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this work is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides, these methods not only decrease practicality due to the process of having to put them on, but they are also very expensive. The system proposed in this paper classifies respiration and body movement with only one type of sensor and also in a noninvasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed excellent results in the classification of breathing rate and body movements.
Assistive environments are entering our homes faster than ever. However, there are still various barriers to be broken. One of the crucial points is a personalization of offered services and integration of assistive technologies in common objects and therefore in a regular daily routine. Recognition of sleep patterns for the preliminary sleep study is one of the Health services that could be performed in an undisturbing way. This article proposes the hardware system for the measurement of bio-vital signals necessary for initial sleep study in a nonobtrusive way. The first results confirm the potential of measurement of breathing and movement signals with the proposed system.
Due to the rising need for palliative care in Russia, it is crucial to provide timely and high-quality solutions for patients, relatives, and caregivers. A methodology for remote monitoring of patients in need of palliative care and the requirements will be developed for a hardware-software complex for remote monitoring of patients' health at home.
Artefaktkorrektur und verfeinerte Metriken für ein EEG-basiertes System zur Müdigkeitserkennung
(2019)
Fragestellung: Müdigkeit ist ein oft unterschätztes, aber dennoch großes Problem im Straßenverkehr. Von rund 2,5 Mio. Verkehrsunfällen 2015 in Deutschland, waren 2898 Unfälle, mit insgesamt 59 Toten (~1,7 % der Todesfälle), auf Übermüdung zurückzuführen. Schätzungen gehen von einer Dunkelziffer von bis zu 20 % aus. In einer ersten eigenen Studie wurde überprüft, ob ein mobiles EEG in einem Fahrsimulator Müdigkeitszustände zuverlässig erkennen kann. Die Erkennungsrate lag lediglich bei 61 %. Ziel dieser Arbeit ist, das verwendete Messsystem zu verbessern. Dazu wird die Genauigkeit durch eine Artefaktkorrektur und mit Hilfe von verfeinerten Qualitätsmetriken erhöht. Eine erkannte Übermüdung wird dem Fahrer dann in angemessener Weise angezeigt, so dass er entsprechend reagieren kann.
Patienten und Methoden: Die Independent Component Analysis (ICA) ist ein multivariates Verfahren, um mehrere Zufallsvariablen zu analysieren. Für die Entscheidung, ob ein Fahrer gerade müde oder wach ist, wird der erstellte Merkmalsvektor für jede Sequenz mit ICA klassifiziert. Dafür wird ein trainierter Machine-Learning-Algorithmus eingesetzt, der in der Lage ist, auch unbekannte Datensätze in Klassen einzuteilen. Um die benötigten Frequenzwerte zu erhalten, wurde für jeden EEG-Kanal eine Fourier Transformation durchgeführt. Der erstellte Merkmalsvektor wird im nächsten Schritt durch ein Künstliches Neuronales Netz klassifiziert. Für das Training werden vorab erstellte Merkmalsvektoren mit den Klassen „Wach“ und „Müde“ versehen. Diese Daten werden zufällig gemischt und im Verhältnis 2:1 in eine Trainings- und Testmenge geteilt. Das Experiment wurde mit acht Personen mit jeweils zweimal 45 min Testfahrt durchgeführt.
Ergebnisse: Der komplette Datensatz besteht aus 150.000 Signalwerten, welche zu ca. 7000 Sequenzen zusammengefasst werden. Durch die Anwendung der Qualitätsmetrik bleiben 4370 Sequenzen für das Training übrig. Bei invaliden Sequenzen aufgrund von EEG-Artefakten gibt es deutliche Unterschiede. Im „Wach“ Zustand werden dreimal so viele Sequenzen verworfen als im „Müde“ Zustand. Insgesamt werden bei wachen Probanden im Schnitt ca. 50 % der Sequenzen verworfen, bei Müden lediglich 25 %. Im Durchschnitt erreicht das System eine Erkennungsrate von 73 % für beide Zustände. Vergleicht man nun das Verhältnis von „Wach“ und „Müde“ und lässt „Leichte Müdigkeit“ außen vor, liegen die Ergebnisse bei über 90 %.
Schlussfolgerungen: Die Ergebnisse zeigen, dass die Aufmerksamkeit während des Experiments abnimmt bzw. die Müdigkeit zunimmt. Dies verdeutlichen zum einen subjektive und objektive Beobachtungen von Müdigkeitsanzeichen. Zum anderen lassen sich messbare und klassifizierbare Unterschiede im EEG Signal nachweisen. Die als Merkmale eingesetzten Theta-Wellen zeigten eine niedrigere Amplitude gegen Ende des Experiments. Die Erweiterung der binären Klassifizierung führt zu einer weiteren Stabilisierung der Ergebnisse. Artefaktkorrektur und Qualitätsmetriken steigern die Güte der Daten weiter. Die entwickelte Anwendung zur Müdigkeitserkennung ermittelt messbare Zeichen von Müdigkeit und kann eine gute Entscheidung über die Fahrtauglichkeit treffen.