530 Physik
Refine
Document Type
- Journal article (30)
- Book (1)
- Book chapter (1)
- Conference proceeding (1)
Is part of the Bibliography
- yes (33) (remove)
Institute
- Life Sciences (21)
- Technik (8)
- Informatik (3)
- ESB Business School (1)
Publisher
- Elsevier (6)
- Springer (5)
- EMW (3)
- MDPI (3)
- Optical Society of America (2)
- Wiley (2)
- ACS (1)
- DEGA (1)
- EDP Sciences (1)
- EMW Publishing (1)
Comparative analysis of the chemical and rheological curing kinetics of formaldehyde-based wood adhesives is crucial for assessing their respective performance. Differential scanning calorimetry (DSC) and rheometry are the conventional techniques used for monitoring the curing processes leading to crosslinking polymerization of the adhesives. However, the direct comparison of these techniques is inappropriate due to the intrinsic differences in their underlying procedures. To address this challenge, the two adhesive samples were sequentially cured, firstly with rheometry and followed by DSC. The observed higher curing degree in the subsequent DSC procedure underpins the incomplete curing of the samples during initial rheometry. Furthermore, the comparative assessment of the activation energies, molar ratios, and active groups of the two adhesives highlights the importance of the pre-exponential factor in addition to the activation energies, as it attributes to the probability of active groups coinciding at the appropriate spatial arrangement.
Film formation of self synthesized Polymer EPM–g–VTMDS (ethylene–propylene rubber, EPM, grafted with vinyltetramethyldisiloxane, VTMDS) was studied regarding bonding to adhesion promoter vinyltrimethoxysilane (VTMS) on oxidized 18/10 chromium/nickel–steel (V2A) stainless steel surfaces. Polymer films of different mixed solutions including commercial siloxane and silicone, dimethyl, vinyl group terminated crosslinker (HANSA SFA 42100, CAS# 68083-19-2, 0.35 mmol Vinyl/g) and platinum, 1,3-diethenyl-1,1,3,3-tetramethyldisiloxane complex Karstedt's catalyst (ALPA–KAT 1, CAS# 68478-92-2) were spin coated on V2A stainless steel surfaces with adsorbed VTMS thin layers in order to analyze film formation of EPM–g–VTMDS at early stages. Surface topography and chemical bonding of the high performance polymers on different oxidized V2A surfaces were investigated with X–ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM) and surface enhanced Raman spectroscopy (SERS). AFM and SEM as well as XPS results indicated that the formation of the polymer film proceeds via growth of polymer islands. Chemical signatures of the essential polymer contributions, linker and polymer backbones, could be identified using XPS core level peak shape analysis and also SERS. The appearance of signals which are related to Si–O–Si can be seen as a clear indication of lateral crosslinking and silica network formation in the films on the V2A surface.
Mesoporous silica microspheres (MPSMs) find broad application as separation materials in high liquid chromatography (HPLC). A promising preparation strategy uses p(GMA-co-EDMA) as hard templates to control the pore properties and a narrow size distribution of the MPMs. Here six hard templates were prepared which differ in their porosity and surface functionalization. This was achieved by altering the ratio of GMA to EDMA and by adjusting the proportion of monomer and porogen in the polymerization process. The various amounts of GMA incorporated into the polymer network of P1-6 lead to different numbers of tetraethylene pentamine in the p(GMA-co-EDMA) template. This was established by a partial least squares regression (PLS-R) model, based on FTIR spectra of the templates. Deposition of silica nanoparticles (SNP) into the template under Stoeber conditions and subsequent removal of the polymer by calcination result in MPSM1-6. The size of the SNPs and their incorporation depends on the pore parameters of the template and degree of TEPA functionalization. Moreover, the incorporated SNPs construct the silica network and control the pore parameters of the MPSMs. Functionalization of the MPSMs with trimethoxy (octadecyl) silane allows their use as a stationary phase for the separation of biomolecules. The pore characteristics and the functionalization of the template determine the pore structure of the silica particles and, consequently, their separation properties.
While driving, stress is caused by situations in which the driver estimates their ability to manage the driving demands as insufficient or loses the capability to handle the situation. This leads to increased numbers of driver mistakes and traffic violations. Additional stressing factors are time pressure, road conditions, or dislike for driving. Therefore, stress affects driver and road safety. Stress is classified into two categories depending on its duration and the effects on the body and psyche: short-term eustress and constantly present distress, which causes degenerative effects. In this work, we focus on distress. Wearable sensors are handy tools for collecting biosignals like heart rate, activity, etc. Easy installation and non-intrusive nature make them convenient for calculating stress. This study focuses on the investigation of stress and its implications. Specifically, the research conducts an analysis of stress within a select group of individuals from both Spain and Germany. The primary objective is to examine the influence of recognized psychological factors, including personality traits such as neuroticism, extroversion, psychoticism, stress and road safety. The estimation of stress levels was accomplished through the collection of physiological parameters (R-R intervals) using a Polar H10 chest strap. We observed that personality traits, such as extroversion, exhibited similar trends during relaxation, with an average heart rate 6% higher in Spain and 3% higher in Germany. However, while driving, introverts, on average, experienced more stress, with rates 4% and 1% lower than extroverts in Spain and Germany, respectively.
Analog integrated circuit sizing is notoriously difficult to automate due to its complexity and scale; thus, it continues to heavily rely on human expert knowledge. This work presents a machine learning-based design automation methodology comprising pre-defined building blocks such as current mirrors or differential pairs and pre-computed look-up tables for electrical characteristics of primitive devices. Modeling the behavior of primitive devices around the operating point with neural networks combines the speed of equation-based methods with the accuracy of simulation-based approaches and, thereby, brings quality of life improvements for analog circuit designers using the gm/Id method. Extending this procedural automation method for human design experts, we present a fully autonomous sizing approach. Related work shows that the convergence properties of conventional optimization approaches improve significantly when acting in the electrical domain instead of the geometrical domain. We, therefore, formulate the circuit sizing task as a sequential decision-making problem in the alternative electrical design space. Our automation approach is based entirely on reinforcement learning, whereby abstract agents learn efficient design space navigation through interaction and without expert guidance. These agents’ learning behavior and performance are evaluated on circuits of varying complexity and different technologies, showing both the feasibility and portability of the work presented here.
In this paper we presented the results of the workshop with the topic: Co-creation in citizen science (CS) for the development of climate adaptation measurements - Which success factors promote, and which barriers hinder a fruitful collaboration and co-creation process between scientists and volunteers? Under consideration of social, motivational, technical/technological and legal factors., which took place at the CitSci2022. We underlined the mentioned factors in the work with scientific literature. Our findings suggest that a clear communication strategy of goals and how citizen scientists can contribute to the project are important. In addition, they have to feel include and that the contribution makes a difference. To achieve this, it is critical to present the results to the citizen scientists. Also, the relationship between scientist and citizen scientists are essential to keep the citizen scientists engaged. Notification of meetings and events needs to be made well in advance and should be scheduled on the attendees' leisure time. The citizen scientists should be especially supported in technical questions. As a result, they feel appreciated and remain part of the project. For legal factors the current General Data Protection Regulation was considered important by the participants of the workshop. For the further research we try to address the individual points and first of all to improve our communication with the citizen scientist about the project goals and how they can contribute. In addition, we should better share the achieved results.
Ausbildung in der Akustik
(2022)
Die Wissenschaft der Akustik mit ihrer Vielfallt und Interdisziplinarität bietet hervorragende Möglichkeiten an beruflichen Betätigungsfeldern und hat viele von uns in ihren Bann gezogen. Ausbildung in der Akustik bedeutet mehr als Studierenden nur Wissen und Fähigkeiten zu vermitteln. Eigentlich ist nach dem Studium auch der Lernprozess nicht abgeschlossen, sondern wie viele Akustiker:innen meinen, fängt dieser erst dann richtig an. Um eine sehr gute Ausbildung zu gestalten, bedarf es neben Vorbildern an Personen auch Lehrformate, Methoden und Tools. Die folgenden sechs Kurzbeiträge sind Beispiele gelungener Maßnahmen in der Ausbildung der Akustik und sollen anregen, die Qualität in der Lehre stetig zu verbessern.
A new planar compact antenna composed of two crossed Cornu spirals is presented. Each Cornu spiral is fed from the center of the linearly part of the curvature between the two spirals, which builds the clothoid. Sequential rotation is applied using a sequential phase network to obtain circular polarization and increase the effective bandwidth. Signal integrity issues have been addressed and designed to ensure high quality of signal propagation. As a result, the antenna shows good radiation characteristics in the bandwidth of interest. Compared to antennas of the same size in the literature, it is broadband and of high gain. Although the proposed antenna has been designed for K- and Ka-band operations, it can also be developed for lower and upper frequencies because of the linearity of the Maxwell equations.
The development of new materials that mimic cartilage and its function is an unmet need that will allow replacing the damaged parts of the joints, instead of the whole joint. Polyvinyl alcohol (PVA) hydrogels have raised special interest for this application due to their biocompatibility, high swelling capacity and chemical stability. In this work, the effect of post-processing treatments (annealing, high hydrostatic pressure (HHP) and gamma-radiation) on the performance of PVA gels obtained by cast-drying was investigated and, their ability to be used as delivery vehicles of the anti-inflammatories diclofenac or ketorolac was evaluated. HHP damaged the hydrogels, breaking some bonds in the polymeric matrix, and therefore led to poor mechanical and tribological properties. The remaining treatments, in general, improved the performance of the materials, increasing their crystallinity. Annealing at 150 °C generated the best mechanical and tribological results: higher resistance to compressive and tensile loads, lower friction coefficients and ability to support higher loads in sliding movement. This material was loaded with the anti-inflammatories, both without and with vitamin E (Vit.E) or Vit.E + cetalkonium chloride (CKC). Vit.E + CKC helped to control the release of the drugs which occurred in 24 h. The material did not induce irritability or cytotoxicity and, therefore, shows high potential to be used in cartilage replacement with a therapeutic effect in the immediate postoperative period.
A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration–diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor Q which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality factor changes with different spectrometer parameters such as grating groove density, the wavelength of excitation, pinhole width, charge-coupled device (CCD) pixel density, etc. This work provides an insight into the quality of a spectrometer and helps to monitor the performance of the spectrometer over a certain period. Commercially available spectrometers or home-built spectrometers are prone to misalignment in optical elements and can benefit from this work that allows maintaining the overall quality of the setup. Performing such experiments over a period helps to minimize the aberration/ diffraction effects occurring as a result of time and maintaining the quality of measurements.