Frost reduction in mechanical balanced ventilation by efficient means of preheating cold supply air
(2019)
This study has focused on evaluating the financial potential of wastewater and geothermal heat recovery systems in a multi-family building. The recovered heat was used to improve the performance of mechanical ventilation with heat recovery (MVHR) system during the coldest days in central Sweden. The main issue, which was targeted with these solutions, was to reduce frost formation in the system and hence increase its thermal efficiency. By looking at the life cycle cost over a lifespan of 20 years, the observed systems were being evaluated economically. Furthermore, statistical analyses were carried-out to counter the uncertainty that comes with the calculation. It was found that the studied wastewater systems have a high possibility of generating savings in this period, while the one fed by geothermal energy is less likely to compensate for its high initial cost. All designed systems however, managed to reduce operational cost by 35-45% due to lower energy usage.
In spite of many studies, knowledge about the fundamental factors influencing adhesion between addition curing silicones and aluminum substrates is very limited. The aim of this publication is to evaluate the influence of the formulation and the surface state of the adherend on bond strength. For this purpose, the composition of an addition curing silicone was systematically varied and the effects on both material and bond properties were examined. Additionally, the influence of surface aging at different humidities (0% r. h., 34% r. h., 82% r. h.) of acid etch pretreated aluminum substrates was considered. It is shown that the mechanical properties of the silicone material can be easily adjusted over a wide range by changing the formulation. Although high tensile strengths up to 9.2 MPa for the silicone material can be achieved, lap-shear strengths remain moderate at approximately 3.5 MPa. Predominant adhesive failures show the limited adhesive strength of the basic formulation without additives. Basic ingredients of addition curing silicones without additives are able to reach a certain adhesive strength. However, this strength was quite limited and adhesion promoters are required to further improve adhesion. The humidity at which the pretreated substrates are stored has an overall minor influence on bond strength. Surprisingly, bond strength tends to increase with the storage time of aluminum substrates despite lower surface energies in comparison to freshly pretreated substrates. All in all, the storage conditions of aluminum had a rather small influence on adhesion, whereas the composition of the silicone adhesive strongly influences bond strength.
Exogenous factors of influence on exhaled breath analysis by ion-mobility spectrometry (MCC/IMS)
(2019)
The interpretation of exhaled breath analysis needs to address to the influence of exogenous factors, especially to a transfer of confounding analytes by the test persons. A test person who was exposed to a disinfectant had exhaled breath analysis by MCC/IMS (Bioscout®) after different time intervals. Additionally, a new sampling method with inhalation of synthetic air before breath analysis was tested. After exposure to the disinfectant, 3-Pentanone monomer, 3-Pentanone dimer, Hexanal, 3-Pentanone trimer, 2-Propanamine, 1-Propanol, Benzene, Nonanal showed significantly higher intensities, in exhaled breath and air of the examination room, compared to the corresponding baseline measurements. Only one ingredient of the disinfectant (1-Propanol) was identical to the 8 analytes. Prolonging the time intervals between exposure and breath analysis showed a decrease of their intensities. However, the half-time of the decrease was different. The inhalation of synthetic air - more than consequently airing the examination room with fresh air - reduced the exogenous and also relevant endogenous analytes, leading to a reduction and even changing polarity of the alveolar gradient. The interpretation of exhaled breath needs further knowledge about the former residence of the proband and the likelihood and relevance of the inhalation of local, site-specific and confounding exogenous analytes by him. Their inhalation facilitates a transfer to the examination room and a detection of high concentrations in room air and exhaled breath, but also the exhalation of new analytes. This may lead to a misinterpretation of these analytes as endogenous resp. disease-specific ones.
Standardisation of breath sampling is important for application of breath analysis in clinical settings. By studying the effect of room airing on indoor and breath analytes and by generating time series of room air with different sampling intervals we sought to get further insights into room air metabolism, to detect the relevance of exogenous VOCs and to make conclusions about their consideration for the interpretation of exhaled breath. Room air and exhaled breath of a healthy subject were analysed before and after room airing. Furthermore a time series of room air with doors and windows closed was taken over 84 h by an automatic sampling every 180 min. A second times series studied room air analytes over 70 h with samples taken every 16.5 min. For breath and room air measurements an IMS coupled to a multi-capillary column (IMS/MCC) [Bio-Scout® - B&S Analytik GmbH, Dortmund, Germany] was used. The peaks were characterized using the Software Visual Now (B&S Analytik, Dortmund Germany) and identified using the software package MIMA (version 1.1, provided by the Max Planck Institute for Informatics, Saarbrücken, Germany) and the database 20160426_SubstanzDbNIST_122 (B & S Analytik GmbH, Dortmund, Germany). In the morning 4 analytes (Decamethylcylopentasiloxane [541-02-6]; Pentan-2-one [107-87-9] – Dimer; Hexan-1-al [66-25-1]; Pentan-2-one [107-87-9]) – Monomer showed high intensities in the room air and exhaled breath. They were significantly but not equally reduced by room airing. The time series about 84 h showed a time dependent decrease of analytes (limonen-monomer and -dimer; Decamethylcylopentasiloxane, Butan-1-ol, Butan-1-ol) as well as increase (Pentan-2-one [107-87-9] – Dimer). Shorter sampling intervals exhibited circadian variations of analyte concentrations for many analytes. Breath sampling in the morning needs room airing before starting. Then the variation of the intensity of indoor analytes can be kept small. The time series of indoor analytes show, that their intensities have a different behaviour, with time dependent declines, constant increases and circadian variations, dependent on room airing. This has implications on the breath sampling procedure and the intrepretation of exhaled breath.
Stronger than they look
(2019)