530 Physik
Refine
Document Type
- Journal article (30)
- Book (1)
- Book chapter (1)
- Conference proceeding (1)
Is part of the Bibliography
- yes (33)
Institute
- Life Sciences (21)
- Technik (8)
- Informatik (3)
- ESB Business School (1)
Publisher
- Elsevier (6)
- Springer (6)
- EMW (4)
- MDPI (3)
- Optical Society of America (2)
- Wiley (2)
- American Chemical Society (1)
- DEGA (1)
- De Gruyter (1)
- EDP Sciences (1)
In spite of many studies, knowledge about the fundamental factors influencing adhesion between addition curing silicones and aluminum substrates is very limited. The aim of this publication is to evaluate the influence of the formulation and the surface state of the adherend on bond strength. For this purpose, the composition of an addition curing silicone was systematically varied and the effects on both material and bond properties were examined. Additionally, the influence of surface aging at different humidities (0% r. h., 34% r. h., 82% r. h.) of acid etch pretreated aluminum substrates was considered. It is shown that the mechanical properties of the silicone material can be easily adjusted over a wide range by changing the formulation. Although high tensile strengths up to 9.2 MPa for the silicone material can be achieved, lap-shear strengths remain moderate at approximately 3.5 MPa. Predominant adhesive failures show the limited adhesive strength of the basic formulation without additives. Basic ingredients of addition curing silicones without additives are able to reach a certain adhesive strength. However, this strength was quite limited and adhesion promoters are required to further improve adhesion. The humidity at which the pretreated substrates are stored has an overall minor influence on bond strength. Surprisingly, bond strength tends to increase with the storage time of aluminum substrates despite lower surface energies in comparison to freshly pretreated substrates. All in all, the storage conditions of aluminum had a rather small influence on adhesion, whereas the composition of the silicone adhesive strongly influences bond strength.
Exogenous factors of influence on exhaled breath analysis by ion-mobility spectrometry (MCC/IMS)
(2019)
The interpretation of exhaled breath analysis needs to address to the influence of exogenous factors, especially to a transfer of confounding analytes by the test persons. A test person who was exposed to a disinfectant had exhaled breath analysis by MCC/IMS (Bioscout®) after different time intervals. Additionally, a new sampling method with inhalation of synthetic air before breath analysis was tested. After exposure to the disinfectant, 3-Pentanone monomer, 3-Pentanone dimer, Hexanal, 3-Pentanone trimer, 2-Propanamine, 1-Propanol, Benzene, Nonanal showed significantly higher intensities, in exhaled breath and air of the examination room, compared to the corresponding baseline measurements. Only one ingredient of the disinfectant (1-Propanol) was identical to the 8 analytes. Prolonging the time intervals between exposure and breath analysis showed a decrease of their intensities. However, the half-time of the decrease was different. The inhalation of synthetic air - more than consequently airing the examination room with fresh air - reduced the exogenous and also relevant endogenous analytes, leading to a reduction and even changing polarity of the alveolar gradient. The interpretation of exhaled breath needs further knowledge about the former residence of the proband and the likelihood and relevance of the inhalation of local, site-specific and confounding exogenous analytes by him. Their inhalation facilitates a transfer to the examination room and a detection of high concentrations in room air and exhaled breath, but also the exhalation of new analytes. This may lead to a misinterpretation of these analytes as endogenous resp. disease-specific ones.
Standardisation of breath sampling is important for application of breath analysis in clinical settings. By studying the effect of room airing on indoor and breath analytes and by generating time series of room air with different sampling intervals we sought to get further insights into room air metabolism, to detect the relevance of exogenous VOCs and to make conclusions about their consideration for the interpretation of exhaled breath. Room air and exhaled breath of a healthy subject were analysed before and after room airing. Furthermore a time series of room air with doors and windows closed was taken over 84 h by an automatic sampling every 180 min. A second times series studied room air analytes over 70 h with samples taken every 16.5 min. For breath and room air measurements an IMS coupled to a multi-capillary column (IMS/MCC) [Bio-Scout® - B&S Analytik GmbH, Dortmund, Germany] was used. The peaks were characterized using the Software Visual Now (B&S Analytik, Dortmund Germany) and identified using the software package MIMA (version 1.1, provided by the Max Planck Institute for Informatics, Saarbrücken, Germany) and the database 20160426_SubstanzDbNIST_122 (B & S Analytik GmbH, Dortmund, Germany). In the morning 4 analytes (Decamethylcylopentasiloxane [541-02-6]; Pentan-2-one [107-87-9] – Dimer; Hexan-1-al [66-25-1]; Pentan-2-one [107-87-9]) – Monomer showed high intensities in the room air and exhaled breath. They were significantly but not equally reduced by room airing. The time series about 84 h showed a time dependent decrease of analytes (limonen-monomer and -dimer; Decamethylcylopentasiloxane, Butan-1-ol, Butan-1-ol) as well as increase (Pentan-2-one [107-87-9] – Dimer). Shorter sampling intervals exhibited circadian variations of analyte concentrations for many analytes. Breath sampling in the morning needs room airing before starting. Then the variation of the intensity of indoor analytes can be kept small. The time series of indoor analytes show, that their intensities have a different behaviour, with time dependent declines, constant increases and circadian variations, dependent on room airing. This has implications on the breath sampling procedure and the intrepretation of exhaled breath.
Zero or plus energy office buildings must have very high building standards and require highly efficient energy supply systems due to space limitations for renewable installations. Conventional solar cooling systems use photovoltaic electricity or thermal energy to run either a compression cooling machine or an absorption-cooling machine in order to produce cooling energy during daytime, while they use electricity from the grid for the nightly cooling energy demand. With a hybrid photovoltaic-thermal collector, electricity as well as thermal energy can be produced at the same time. These collectors can produce also cooling energy at nighttime by longwave radiation exchange with the night sky and convection losses to the ambient air. Such a renewable trigeneration system offers new fields of applications. However, the technical, ecological and economical aspects of such systems are still largely unexplored.
In this work, the potential of a PVT system to heat and cool office buildings in three different climate zones is investigated. In the investigated system, PVT collectors act as a heat source and heat sink for a reversible heat pump. Due to the reduced electricity consumption (from the grid) for heat rejection, the overall efficiency and economics improve compared to a conventional solar cooling system using a reversible air-to-water heat pump as heat and cold source.
A parametric simulation study was carried out to evaluate the system design with different PVT surface areas and storage tank volumes to optimize the system for three different climate zones and for two different building standards. It is shown such systems are technically feasible today. With a maximum utilization of PV electricity for heating, ventilation, air conditioning and other electricity demand such as lighting and plug loads, high solar fractions and primary energy savings can be achieved.
Annual costs for such a system are comparable to conventional solar thermal and solar electrical cooling systems. Nevertheless, the economic feasibility strongly depends on country specific energy prices and energy policy. However, even in countries without compensation schemes for energy produced by renewables, this system can still be economically viable today. It could be shown, that a specific system dimensioning can be found at each of the investigated locations worldwide for a valuable economic and ecological operation of an office building with PVT technologies in different system designs.
Strong optical mode coupling between two adjacent λ/2 Fabry-Pérot microresonators consisting of three parallel silver mirrors is investigated experimentally and theoretically as a function of their detuning and coupling strength. Mode coupling can be precisely controlled by tuning the mirror spacing of one resonator with respect to the other by piezoelectric actuators. Mode splitting, anti-crossing and asymmetric modal damping are observed and theoretically discussed for the symmetric and antisymmetric supermodes of the coupled system. The spectral profile of the supermodes is obtained from the Fourier transform of the numerically calculated time evolution of the individual resonator modes, taking into account their resonance frequencies, damping and coupling constants, and is in excellent agreement with the experiments. Our microresonator design has potential applications for energy transfer between spatially separated quantum systems in micro optoelectronics and for the emerging field of polaritonic chemistry.
Stronger than they look
(2019)
We present a topology of MIMO arrays of inductive antennas exhibiting inherent high crosstalk cancellation capabilities. A single layer PCB is etched into a 3-channels array of emitting/receiving antennas. Once coupled with another similar 3-channels emitter/receiver, we measured an Adjacent Channel Rejection Ratio (ACRR) as high as 70 dB from 150 Hz to 150 kHz. Another primitive device made out of copper wires wound around PVC tubes to form a 2-channels “non-contact slip-ring” exhibited 22 dB to 47 dB of ACRR up to 15MHz. In this paper we introduce the underlying theoretical model behind the crosstalk suppression capabilities of those so-called “Pie-Chart antennas”: an extension of the mutual inductance compensation method to higher number of channels using symmetries. We detail the simple iterative building process of those antennas, illustrate it with numerical analysis and evaluate there effectiveness via real experiments on the 3-channels PCB array and the 2-channels rotary array up to the limit of our test setup. The Pie Chart design is primarily intended as an alternative solution to costly electronic filters or cumbersome EM shields in wireless AND wired applications, but not exclusively.
Here we report a simple way to enhance the resolution of a confocal scanning microscope under cryogenic conditions. Using a microscope objective (MO) with high numerical aperture (NA = 1:25) and 1-propanol as an immersion fluid with low freezing temperature we were able to reach an imaging resolution at 160 K comparable to ambient conditions. The MO and the sample were both placed inside the inner chamber of the cryostat to reduce distortions induced by temperature gradients. The image quality of our commercially available MO was further enhanced by scanning the sample (sample scanning) in contrast to beam scanning. The ease of the whole procedure marks an essential step towards the development of cryo high-resolution microscopy and correlative light and electron cryo microscopy (cryoCLEM).
Reflectometry is known since long as an interferometric method which can be used to characterize surfaces and thin films regarding their structure and,to a certain degree,composition as well.Properties like layer structures,layer thickness,density,and interface roughness can be determined by fitting the obtained reflectivity data with an appropriate model using a recursive fitting routine. However,one major drawback of the reflectometric method is its restriction to planar surfaces.In this article we demonstrate an approach to apply X-ray and neutron reflectometry to curved surfaces by means of the example of bent bare and coated glass slides.We prove the possibility to observe all features like Fresnel decay,Kiessig fringes,Bragg peaks and off-specular scattering and are able to interpret the data using common fitting software and to derive quantitative results about roughness,layer thickness and internal structure. The proposed method has become practical due to the availability of high quality 2D-detectors. It opens up the option to explore many kinds and shapes of samples,which,due to their geometry,have not been in the focus of reflectometry techniques until now.