The present study investigated the possibilities and limitations of using a low-cost NIR spectrometer for the verification of the presence of the declared active pharmaceutical ingredients (APIs) in tablet formulations, especially for medicine screening studies in low-resource settings. Spectra from 950 to 1650 nm were recorded for 170 pharmaceutical products representing 41 different APIs, API combinations or placebos. Most of the products, including 20 falsified medicines, had been collected in medicine quality studies in African countries. After exploratory principal component analysis, models were built using data-driven soft independent modelling of class analogy (DD-SIMCA), a one-class classifier algorithm, for tablet products of penicillin V, sulfamethoxazole/trimethoprim, ciprofloxacin, furosemide, metronidazole, metformin, hydrochlorothiazide, and doxycycline. Spectra of amoxicillin and amoxicillin/clavulanic acid tablets were combined into a single model. Models were tested using Procrustes cross-validation and by projection of spectra of tablets containing the same or different APIs. Tablets containing no or different APIs could be identified with 100 % specificity in all models. A separation of the spectra of amoxicillin and amoxicillin/clavulanic acid tablets was achieved by partial least squares discriminant analysis. 15 out of 19 external validation products (79 %) representing different brands of the same APIs were correctly identified as members of the target class; three of the four rejected samples showed an API mass percentage of the total tablet weight that was out of the range covered in the respective calibration set. Therefore, in future investigations larger and more representative spectral libraries are required for model building. Falsified medicines containing no API, incorrect APIs, or grossly incorrect amounts of the declared APIs could be readily identified. Variation between different NIR-S-G1 spectroscopic devices led to a loss of accuracy if spectra recorded with different devices were pooled. Therefore, piecewise direct standardization was applied for calibration transfer. The investigated method is a promising tool for medicine screening studies in low-resource settings.
Polyurethane thermosets have a wide range of applications. In this study, alternative raw materials were used to enhance sustainability. In two newly developed biobased polyurethanes (PUs), the cross-linker content was varied, which caused phase separation and therefore affected the turbidity. To investigate this phenomenon, UV–Vis–NIR spectroscopy was utilized. Spectra were recorded from 200 to 2500 nm in transmittance mode, and multivariate data analysis was applied to the three UV, Vis, and NIR sections separately. For the two different PU classes, each with five different cross-linker contents, classification by principal component analysis combined with linear or quadratic discriminant analysis was possible with an accuracy between 93% and nearly 100%. The best separation was achieved in the NIR range. Partial least-squares regression models were determined to predict the cross-linker content. As mentioned, the model for the NIR range is the most suitable, with the highest R2 (validation) of 0.99 for PU1 and 0.98 for PU2. The corresponding root-mean-square error of prediction values of the external validation was the lowest, with 0.82% (PU1) and 1.25% (PU2). Therefore, UV–Vis–NIR absorbance spectroscopy, especially NIR, is a suitable tool for monitoring the appropriate material composition of turbid PU thermosets in line.
Determination of the gel point of formaldehyde-based wood adhesives by using a multiwave technique
(2023)
Determining the instant of gelation of formaldehyde-based wood adhesives as an assessment parameter for their curing rate is important for optimizing the curing behavior. Due to the stoichiometrically imbalanced networks of formaldehyde-based adhesives, the crossover point of storage G′ and loss modulus G″ cannot unconditionally be assumed as the gel point in oscillatory time sweeps as the material response is frequency-dependent. This study aims to determine the gel point of selected adhesives by the isothermal multiwave oscillatory shear test. A thorough comparison between the gel and the crossover point of G′ and G″ is performed. Rheokinetic analysis showed no significant difference between the activation energies calculated at the gel point determined by a multiwave test and the crossover point obtained by the time sweep test. Hence, for resins with similar curing reactions, a reliable determination of gel point by applying a multiwave test is needed for a comparison of their reactivity.
Sol-gel-controlled size and morphology of mesoporous silica microspheres using hard templates
(2023)
Mesoporous silica microspheres (MPSMs) represent a promising material as a stationary phase for HPLC separations. The use of hard templates provides a preparation strategy for producing such monodisperse silica microspheres. Here, 15 MPSMs were systematically synthesized by varying the sol–gel reaction parameters of water-to-precursor ratio and ammonia concentration in the presence of a porous p(GMA-co-EDMA) polymeric hard template. Changing the sol–gel process factors resulted in a wide range of MPSMs with varying particle sizes from smaller than one to several micrometers. The application of response surface methodology allowed to derive quantitative predictive models based on the process factor effects on particle size, pore size, pore volume, and specific surface area of the MPSMs. A narrow size distribution of the silica particles was maintained over the entire experimental space. Two larger-scale batches of MPSMs were prepared, and the particles were functionalized with trimethoxy(octadecyl) silane for the application as stationary phase in reversed-phases liquid chromatography. The separation of proteins and amino acids was successfully accomplished, and the effect of the pore properties of the silica particles on separation was demonstrated.
High-performance liquid chromatography is one of the most important analytical tools for the identification and separation of substances. The efficiency of this method is largely determined by the stationary phase of the columns. Although monodisperse mesoporous silica microspheres (MPSM) represent a commonly used material as stationary phase their tailored preparation remains challenging. Here we report on the synthesis of four MPSMs via the hard template method. Silica nanoparticles (SNPs) which form the silica network of the final MPSMs were generated in situ from tetraethyl orthosilicate (TEOS) in the presence of (3-aminopropyl) triethoxysilane (APTES) functionalized p(GMA-co-EDMA) as hard template. Methanol, ethanol, 2-propanol, and 1-butanol were applied as solvents to control the size of the SNPs in the hybrid beads (HB). After calcination, MPSMs with different sizes, morphology and pore properties were obtained and characterized by scanning electron microscopy, nitrogen adsorption and desorption measurements, thermogravimetric analysis, solid state NMR and DRIFT IR spectroscopy. Interestingly, the 29Si NMR spectra of the HBs show T and Q group species which suggests that there is no covalent linkage between the SNPs and the template. The MPSMs were functionalized with trimethoxy (octadecyl) silane and used as stationary phases in reversed-phase chromatography to separate a mixture of eleven different amino acids. The separation characteristics of the MPSMs strongly depend on their morphology and pore properties which are controlled by the solvent during the preparation of the MPSMs. Overall, the separation behavior of the best phases is comparable with those of commercially available columns. The phases even achieve faster separation of the amino acids without loss of quality.
This study introduces a straightforward approach to construct three-dimensional (3D) surface-enhanced Raman spectroscopy (SERS) substrates using chemically modified silica particles as microcarriers and by attaching metal nanoparticles (NPs) onto their surfaces. Tollens’ reagent and sputtering techniques are utilized to prepare the SERS substrates from mercapto-functionalized silica particles. Treatment with Tollens’ reagent generates a variety of silver NPs, ranging from approximately 10 to 400 nm, while sputtering with gold (Au) yields uniformly distributed NPs with an island-like morphology. Both substrates display wide plasmon resonances in the scattering spectra, making them effective for SERS in the visible spectral range, with enhancement factors (ratio of the analyte’s intensity at the hotspot compared to that on the substrate in the absence of metal nanoparticles) of up to 25. These 3D substrates have a significant advantage over traditional SERS substrates because their active surface area is not limited to a 2D surface but offers a much greater active surface due to the 3D arrangement of the NPs. This feature may enable achieving much higher SERS intensity from within streaming liquids or inside cells/tissues.
Thin, flat textile roofing offers negligible heat insulation. In warm areas, such roofing membranes are therefore equipped with metallized surfaces to reflect solar heat radiation, thus reducing the warming inside a textile building. Heat reflection effects achieved by metallic coatings are always accompanied by shading effects as the metals are non-transparent for visible light (VIS). Transparent conductive oxides (TCOs) are transparent for VIS and are able to reflect heat radiation in the infrared. TCOs are, e.g., widely used in the display industry. To achieve the perfect coatings needed for electronic devices, these are commonly applied using costly vacuum processes at high temperatures. Vacuum processes, on account of the high costs involved and high processing temperatures, are obstructive for an application involving textiles. Accepting that heat-reflecting textile membranes demand less perfect coatings, a wet chemical approach has been followed here when producing transparent heat-reflecting coatings. Commercially available TCOs were employed as colloidal dispersions or nanopowders to prepare sol-gel-based coating systems. Such coatings were applied to textile membranes as used for architectural textiles using simple coating techniques and at moderate curing temperatures not exceeding 130 °C. The coatings achieved about 90% transmission in the VIS spectrum and reduced near-infrared transmission (at about 2.5 µm) to nearly zero while reflecting up to 25% of that radiation. Up to 35% reflection has been realized in the far infrared, and emissivity values down to ε = 0.5777 have been measured.
We study three-color Förster resonance energy transfer (triple FRET) between three spectrally distinct fluorescent dyes, a donor and two acceptors, which are embedded in a single polystyrene nanosphere. The presence of triple FRET energy transfer is confirmed by selective acceptor photobleaching. We show that the fluorescence lifetimes of the three dyes are selectively controlled using the Purcell effect by modulating the radiative rates and relative fluorescence intensities when the nanospheres are embedded in an optical Fabry–Pérot microcavity. The strongest fluorescence intensity enhancement for the second acceptor can be observed as a signature of the FRET process by tuning the microcavity mode to suppress the intermediate dye emission and transfer more energy from donor to the second acceptor. Additionally, we show that the triple FRET process can be modeled by coupled rate equations, which allow to estimate the energy transfer rates between donor and acceptors. This fundamental study has the potential to extend the classical FRET approach for investigating complex systems, e.g., optical energy switching, photovoltaic devices, light-harvesting systems, or in general interactions between more than two constituents.
Rapid and robust quality monitoring of the composition of meat pastes is of fundamental importance in processing meat and sausage products. Here, an in-line near-infrared spectroscopy/micro-electro-mechanical-system-(MEMS)-based approach, combined with multivariate data analysis, was used for measuring the constituents fat, protein, water, and salt in meat pastes within a typical range of meat paste recipes. The meat pastes were spectroscopically characterized in-line with a novel process analyzer prototype. By integrating salt content in the calibration set, robust predictive PLSR models of high accuracy (R2 > 0.81) were obtained that take interfering matrix effects of the minor and NIR-inactive meat paste recipe component “salt” into account as well. The nonlinear blending behavior of salt concentration on the spectral features of meat pastes is discussed based on a designed mixture experiment with four systematically varied components.
The properties of polyelectrolyte multilayers are ruled by the process parameters employed during self-assembly. This is the first study in which a design of experiment approach was used to validate and control the production of ultrathin polyelectrolyte multilayer coatings by identifying the ranges of critical process parameters (polyelectrolyte concentration, ionic strength and pH) within which coatings with reproducible properties (thickness, refractive index and hydrophilicity) are created. Mathematical models describing the combined impact of key process parameters on coatings properties were developed demonstrating that only ionic strength and pH affect the coatings thickness, but not polyelectrolyte concentration. While the electrolyte concentration had a linear effect, the pH contribution was described by a quadratic polynomial. A significant contribution of this study is the development of a new approach to estimate the thickness of polyelectrolyte multilayer nanofilms by quantitative rhodamine B staining, which might be useful in all cases when ellipsometry is not feasible due to the shape complexity or small size of the coated substrate. The novel approach proposed here overcomes the limitations of known methods as it offers a low spatial sampling size and the ability to analyse a wide area without restrictions on the chemical composition and shape of the substrate.