610 Medizin, Gesundheit
Refine
Document Type
- Journal article (82)
- Conference proceeding (81)
- Book chapter (8)
- Doctoral Thesis (2)
- Book (1)
- Patent / Standard / Guidelines (1)
- Report (1)
Is part of the Bibliography
- yes (176)
Institute
- Informatik (113)
- Life Sciences (47)
- Technik (8)
- ESB Business School (7)
Publisher
- Springer (39)
- Hochschule Reutlingen (17)
- Università Politecnica delle Marche (9)
- Elsevier (8)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e.V. (7)
- MDPI (7)
- IEEE (6)
- IOP (6)
- SPIE (5)
- De Gruyter (4)
Influence of the respirator on volatile organic compounds : an animal study in rats over 24 hours
(2015)
Long-term animal studies are needed to accomplish measurements of volatile organic compounds (VOCs) for medical diagnostics. In order to analyze the time course of VOCs, it is necessary to ventilate these animals. Therefore, a total of 10 male Sprague–Dawley rats were anaesthetized and ventilated with synthetic air via tracheotomy for 24 h. An ion mobility spectrometry coupled to multi-capillary columns (MCC–IMS) was used to analyze the expired air. To identify background contaminations produced by the respirator itself, six comparative measurements were conducted with ventilators only. Overall, a number of 37 peaks could be detected within the positive mode. According to the ratio peak intensity rat/ peak intensity ventilator blank, 22 peaks with a ratio >1.5 were defined as expired VOCs, 12 peaks with a ratio between 0.5 and 1.5 as unaffected VOCs, and three peaks with a ratio <0.5 as resorbed VOCs. The peak intensity of 12 expired VOCs changed significantly during the 24 h measurement. These results represent the basis for future intervention studies. Notably, online VOC analysis with MCC–IMS is possible over 24 h in ventilated rats and allows different experimental approaches.
In dieser Arbeit werden Anforderungen an ein digitales Referenzmodell der Cell and Gene Therapy (CGT) Supply Chain mittels systematischer Literaturrecherche unter partieller Anwendung der Preferred-Reporting-Items-for-Systematic-Reviews-and-Meta-Analyses(PRISMA)-2020-Methode erarbeitet und erläutert. Die Ergebnisse der Literaturrecherche untermauern, dass die CGT Supply Chain standardisierte und automatisierte Prozesse benötigt, gewissen Transportanforderungen gerecht werden sowie eine lückenlose Rückverfolgbarkeit gewährleisten können muss. Die Anforderungen an das Referenzmodell lehnen sich z. T. an die Anforderungen des klassischen Supply-Chain-Operations-Reference(SCOR)-Modells an, bedürfen jedoch einer Veränderung und Weiterentwicklung unter Beachtung der Besonderheiten der CGT Supply Chain. Auf Basis eines Referenzmodells für die CGT Supply Chain, das die aus dieser Arbeit identifizierten Anforderungen beachtet, kann eine übergeordnete Managementplattform aufgebaut werden. Mit der digitalen Abbildung und Vernetzung aller Aktivitäten ist der Grundstein für die Integration in ein Enterprise-Resource-Planning(ERP)-System zum effektiven Data und Process Mining gelegt. Durch eine zunehmend bessere Datenqualität und -quantität entlang der Prozesse der CGT Supply Chain lassen sich verstärkt Informationen über die Prozesse selbst generieren, aus denen weitere Verbesserungsansätze hervorgehen. Eine CGT-Managementplattform bildet demnach die Grundlage für alle Prozesse innerhalb der CGT Supply Chain für einen kontinuierlichen Verbesserungsprozess.
Knee osteoarthritis is a common complication and can lead to total loss of joint function in patients. Treatment by either partial or total knee replacement with appropriate UHMWPE based implantsis highly invasive, may cause complications and may show unsatisfying results. Alternatively, treatment may be done by insertion of an elastic interpositional knee spacer with optimized material characteristics.
We report the development of high performance polyurethane-based polymers modified with bioactive molecules for fabrication of such knee spacers. In order to tailor mechanical and tribological properties and to improve resist to enzymatic degradation we propose a core-shell model for the spacer with specifically adapted properties.
Salivary gland tumors (SGTs) are a relevant, highly diverse subgroup of head and neck tumors whose entity determination can be difficult. Confocal Raman imaging in combination with multivariate data analysis may possibly support their correct classification. For the analysis of the translational potential of Raman imaging in SGT determination, a multi-stage evaluation process is necessary. By measuring a sample set of Warthin tumor, pleomorphic adenoma and non-tumor salivary gland tissue, Raman data were obtained and a thorough Raman band analysis was performed. This evaluation revealed highly overlapping Raman patterns with only minor spectral differences. Consequently, a principal component analysis (PCA) was calculated and further combined with a discriminant analysis (DA) to enable the best possible distinction. The PCA-DA model was characterized by accuracy, sensitivity, selectivity and precision values above 90% and validated by predicting model-unknown Raman spectra, of which 93% were classified correctly. Thus, we state our PCA-DA to be suitable for parotid tumor and non-salivary salivary gland tissue discrimination and prediction. For evaluation of the translational potential, further validation steps are necessary.
The number of publications in the field of breath analysis using different types of ion mobility spectrometers (IMS) has increased over the last few years. In this paper, the publications between 2010 and 2013 are reviewed with respect to different types of IMS such as differential mobility spectrometers, high-field asymmetric waveform ion mobility spectrometers and multi-capillary columns coupled to conventional IMS. The analytes detected by IMS and declared with significance to a specific medical question were considered further with respect to medical and analytical questions. In total, 42 different analytes were found to be detected using IMS on a high significance level and were compared to findings using other analytical methods with respect to the individual analyte.
Background: Conventional methods for lung cancer detection including computed tomography (CT) and bronchoscopy are expensive and invasive. Thus, there is still a need for an optimal lung cancer detection technique. Methods: The exhaled breath of 50 patients with lung cancer histologically proven by bronchoscopic biopsy samples (32 adenocarcinomas, 10 squamous cell carcinomas, 8 small cell carcinomas), were analyzed using ion mobility spectrometry (IMS) and compared with 39 healthy volunteers. As a secondary assessment, we compared adenocarcinoma patients with and without epidermal growth factor receptor (EGFR) mutation. Results: A decision tree algorithm could separate patients with lung cancer including adenocarcinoma, squamous cell carcinoma and small cell carcinoma. One hundred-fifteen separated volatile organic compound (VOC) peaks were analyzed. Peak-2 noted as n-Dodecane using the IMS database was able to separate values with a sensitivity of 70.0% and a specificity of 89.7%. Incorporating a decision tree algorithm starting with n-Dodecane, a sensitivity of 76% and specificity of 100% was achieved. Comparing VOC peaks between adenocarcinoma and healthy subjects, n-Dodecane was able to separate values with a sensitivity of 81.3% and a specificity of 89.7%. Fourteen patients positive for EGFR mutation displayed a significantly higher n-Dodecane than for the 14 patients negative for EGFR (p<0.01), with a sensitivity of 85.7% and a specificity of 78.6%. Conclusion: In this prospective study, VOC peak patterns using a decision tree algorithm were useful in the detection of lung cancer. Moreover, n-Dodecane analysis from adenocarcinoma patients might be useful to discriminate the EGFR mutation.
Purpose
Injury or inflammation of the middle ear often results in the persistent tympanic membrane (TM) perforations, leading to conductive hearing loss (HL). However, in some cases the magnitude of HL exceeds that attributable by the TM perforation alone. The aim of the study is to better understand the effects of location and size of TM perforations on the sound transmission properties of the middle ear.
Methods
The middle ear transfer functions (METF) of six human temporal bones (TB) were compared before and after perforating the TM at different locations (anterior or posterior lower quadrant) and to different degrees (1 mm, ¼ of the TM, ½ of the TM, and full ablation). The sound-induced velocity of the stapes footplate was measured using single-point laser-Doppler-vibrometry (LDV). The METF were correlated with a Finite Element (FE) model of the middle ear, in which similar alterations were simulated.
Results
The measured and calculated METF showed frequency and perforation size dependent losses at all perforation locations. Starting at low frequencies, the loss expanded to higher frequencies with increased perforation size. In direct comparison, posterior TM perforations affected the transmission properties to a larger degree than anterior perforations. The asymmetry of the TM causes the malleus-incus complex to rotate and results in larger deflections in the posterior TM quadrants than in the anterior TM quadrants. Simulations in the FE model with a sealed cavity show that small perforations lead to a decrease in TM rigidity and thus to an increase in oscillation amplitude of the TM mainly above 1 kHz.
Conclusion
Size and location of TM perforations have a characteristic influence on the METF. The correlation of the experimental LDV measurements with an FE model contributes to a better understanding of the pathologic mechanisms of middle-ear diseases. If small perforations with significant HL are observed in daily clinical practice, additional middle ear pathologies should be considered. Further investigations on the loss of TM pretension due to perforations may be informative.
Motivation
In order to enable context-aware behavior of surgical assistance systems, the acquisition of various information about the current intraoperative situation is crucial. To achieve this, the complex task of situation recognition can be delegated to a specialized system. Consequently, a standardized interface is required for the seamless transfer of the recognized contextual information to the assistance systems, enabling them to adapt accordingly.
Methods
Our group analyzed four medical interface standards to determine their suitability for exchanging intraoperative contextual information. The assessment was based on a harmonized data and service model derived from the requirements of expected context-aware use cases. The Digital Imaging and Communications in Medicine (DICOM) and IEEE 11073 for Service-oriented Device Connectivity (SDC) were identified as the most appropriate standards.
Results
We specified how DICOM Unified Procedure Steps (UPS), can be used to effectively communicate contextual information. We proposed the inclusion of attributes to formalize different granularity levels of the surgical workflow.
Conclusions
DICOM UPS SOP classes can be used for the exchange of intraoperative contextual information between a situation recognition system and surgical assistance systems. This can pave the way for vendor-independent context awareness in the OR, leading to targeted assistance of the surgical team and an improvement of the surgical workflow.
This paper investigates the possibility to effectively monitor and control the respiratory action using a very simple and non invasive technique based on a single lightweight reduced-size wireless surface electromyography (sEMG) sensor placed below the sternum. The captured sEMG signal, due to the critical sensor position, is characterized by a low energy level and it is affected by motion artifacts and cardiac noise. In this work we present a preliminary study performed on adults for assessing the correlation of the spirometry signal and the sEMG signal after the removal of the superimposed heart signal. This study and the related findings could be useful in respiratory monitoring of preterm infants.
Gamification is one of the recognized methods of motivating people in various life processes, and it has spread to many spheres of life, including healthcare. This article proposes a system design for long-term care patients using the method mentioned. The proposed system aims to increase patient engagement in the treatment and rehabilitation process via gamification. Literature research on available and earlier proposed systems was conducted to develop a suited system design. The primary target group includes bedridden patients and a sedentary lifestyle (predominantly lying in bed). One of the main criteria for selecting a suitable option was its contactless realization for the mentioned target groups in long-term care cases. As a result, we developed the system design for hardware and software that could prevent bedsores and other health problems from occurring because of low activity. The proposed design can be tested in hospitals, nursing homes, and rehabilitation centers.
Sleep is extremely important for physical and mental health. Although polysomnography is an established approach in sleep analysis, it is quite intrusive and expensive. Consequently, developing a non-invasive and non-intrusive home sleep monitoring system with minimal influence on patients, that can reliably and accurately measure cardiorespiratory parameters, is of great interest. The aim of this study is to validate a non-invasive and unobtrusive cardiorespiratory parameter monitoring system based on an accelerometer sensor. This system includes a special holder to install the system under the bed mattress. The additional aim is to determine the optimum relative system position (in relation to the subject) at which the most accurate and precise values of measured parameters could be achieved. The data were collected from 23 subjects (13 males and 10 females). The obtained ballistocardiogram signal was sequentially processed using a sixth-order Butterworth bandpass filter and a moving average filter. As a result, an average error (compared to reference values) of 2.24 beats per minute for heart rate and 1.52 breaths per minute for respiratory rate was achieved, regardless of the subject’s sleep position. For males and females, the errors were 2.28 bpm and 2.19 bpm for heart rate and 1.41 rpm and 1.30 rpm for respiratory rate. We determined that placing the sensor and system at chest level is the preferred configuration for cardiorespiratory measurement. Further studies of the system’s performance in larger groups of subjects are required, despite the promising results of the current tests in healthy subjects.
Die Bereitstellung klinischer Informationen im Operationssaal ist ein wichtiger Aspekt zur Unterstützung des chirurgischen Teams. Die roboter-assistierte Ösophagusresektion ist ein besonders komplexer Eingriff, der Potenzial zur workflowbasierten Unterstützung bietet. Wir präsentieren erste Ergebnisse der Entwicklung eines Checklisten-Tools mit der zugrundeliegenden Modellierung des chirurgischen Workflows und Informationsbedarf der Chirurgen. Das Checklisten-Tool zeigt hierfür die durchzuführenden Schritte chronologisch an und stellt zusätzliche Informationen kontextadaptiert bereit. Eine automatische Dokumentation von Start- und Endzeiten einzelner OP-Phasen und Schritte soll zukünftige Prozessanalysen der Operation ermöglichen.
Multi-dimensional patient data, such as time varying volume data, data of different imaging modalities, surface segmentations etc. are of growing importance in the clinical routine. For many use cases, it is of major importance to replicate a certain visualization of a data set created on one machine on a different computer using different software tools. Up until now, there exists no standardized methodology for this consistent presentation. We propose an extension of the Digital Imaging und Communications in Medicine (DICOM) called “Multi dimensional Presentation State” and outline scope and first results of the standardization process.
In order to evaluate the performance of different stapes prosthesis types, a coupled finite element (FE) model of human ear was developed. First, the middle-ear FE model was developed and validated using the middle-ear transfer function measurements available in literature including pathological cases. Then, the inner-ear FE model was developed and validated using tonotopy, impedance, and level of cochlea amplification curves from literature. Both models are based on pre-existing research with some improvements and were combined into one coupled FE model. The stapes in the coupled FE ear model was replaced with a model of a stapes prosthesis to create a reconstructed ear model that can be used to estimate how different types of protheses perform relative to each other as well as to the natural ear. This will help in designing of new innovative types of stapes prostheses or any other type of middle-ear prostheses as well as to improve the ones that are already available on the market.
This study describes a non-contact measuring and parameter identification procedure designed to evaluate inhomogeneous stiffness and damping characteristics of the annular ligament in the physiological amplitude and frequency range without the application of large static external forces that can cause unnatural displacements of the stapes. To verify the procedure, measurements were first conducted on a steel beam. Then, measurements on an individual human cadaveric temporal bone sample were performed. The estimated results support the inhomogeneous stiffness and damping distribution of the annular ligament and are in a good agreement with the multiphoton microscopy results which show that the posterior-inferior corner of the stapes footplate is the stiffest region of the annular ligament. This method can potentially help to establish a correlation between stiffness and damping characteristics of the annular ligament and inertia properties of the stapes and, thus, help to reduce the number of independent parameters in the model-based hearing diagnosis.
Motivation: Aim of this project is the automatic classification of total hip endoprosthesis (THEP) components in 2D Xray images. Revision surgeries of total hip arthroplasty (THA) are common procedures in orthopedics and trauma surgery. Currently, around 400.000 procedures per year are performed in the United States (US) alone. To achieve the best possible result, preoperative planning is crucial. Especially if parts of the current THEP system are to be retained.
Methods: First, a ground truth based on 76 X-ray images was created: We used an image processing pipeline consisting of a segmentation step performed by a convolutional neural network and a classification step performed by a support vector machine (SVM). In total, 11 classes (5 pans and 6 shafts) shall be classified.
Results: The ground truth generated was of good quality even though the initial segmentation was performed by technicians. The best segmentation results were achieved using a U-net architecture. For classification, SVM architectures performed much better than additional neural networks.
Conclusions: The overall image processing pipeline performed well, but the ground truth needs to be extended to include a broader variability of implant types and more examples per training class.
Perceptual integration of kinematic components in the recognition of emotional facial expressions
(2018)
According to a long-standing hypothesis in motor control, complex body motion is organized in terms of movement primitives, reducing massively the dimensionality of the underlying control problems. For body movements, this low dimensional organization has been convincingly demonstrated by the learning of low-dimensional representations from kinematic and EMG data. In contrast, the effective dimensionality of dynamic facial expressions is unknown, and dominant analysis approaches have been based on heuristically defined facial ‘‘action units,’’ which reflect contributions of individual face muscles. We determined the effective dimensionality of dynamic facial expressions by learning of a low dimensional model from 11 facial expressions. We found an amazingly low dimensionality with only two movement primitives being sufficient to simulate these dynamic expressions with high accuracy. This low dimensionality is confirmed statistically, by Bayesian model comparison of models with different numbers of primitives, and by a psychophysical experiment that demonstrates that expressions, simulated with only two primitives, are indistinguishable from natural ones.
In addition, we find statistically optimal integration of the emotion information specified by these primitives in visual perception. Taken together, our results indicate that facial expressions might be controlled by a very small number of independent control units, permitting very low dimensional parametrization of the associated facial expression.
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel noninvasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
Personalized remote healthcare monitoring is in continuous development due to the technology improvements of sensors and wearable electronic systems. A state of the art of research works on wearable sensors for healthcare applications is presented in this work. Furthermore, a state of the art of wearable devices, chest and wrist band and smartwatches available on the market for health and sport monitoring is presented in this paper. Many activity trackers are commercially available. The prices are continuously reducing and the performances are improving, but commercial devices do not provide raw data and are therefore not useful for research purposes.
Perforations of the tympanic membrane (TM) can occur as a result of injury or inflammation of the middle ear. These perforations can lead to conductive hearing loss (HL), where in some cases the magnitude of HL exceeds that attributable to the observed TM perforation alone. We aim with this study to better understand the effects of location and size of TM perforations on the sound transmitting properties of the middle ear.
The middle ear transfer function (METF) of six human temporal bones (TB; freshly frozen specimen of body donors) were compared before and after perforation of the TM at different locations (anterior or posterior lower quadrant) and of different sizes (1mm, ¼ of the TM, ½ of the TM, and full ablation). The
METF were correlated with a Finite Element (FE) model of the middle ear, in which similar alterations were simulated.
The measured and simulated FE model METFs exhibited frequency and perforation size dependent amplitude losses at all locations and severities. In direct comparison, posterior TM perforations affected the transmission properties to a larger degree than perforations of the anterior quadrant. This could possibly be caused by an asymmetry of the TM, where the malleus-incus complex rotates and results in larger deflections in the posterior TM half than in the anterior TM half. The FE model of the TM with a sealed cavity suggest that small perforations result in a decrease of TM rigidity and thus to an increase in oscillation amplitude of the TM, mostly above 1 kHz.
The location and size of TM perforations influence the METF in a reproducible way. Correlating our data with the FE model could help to better understand the pathologic mechanisms of middle-ear diseases. If small TM perforations with uncharacteristically significant HL are observed in daily clinical practice, additional middle ear pathologies should be considered. Further investigations on the loss of TM pretension due to perforations may be informative.