610 Medizin, Gesundheit
Refine
Document Type
- Conference proceeding (83)
- Journal article (82)
- Book chapter (8)
- Doctoral Thesis (2)
- Book (1)
- Patent / Standard / Guidelines (1)
- Report (1)
Is part of the Bibliography
- yes (178)
Institute
- Informatik (115)
- Life Sciences (47)
- Technik (8)
- ESB Business School (7)
Publisher
Purpose
For the modeling, execution, and control of complex, non-standardized intraoperative processes, a modeling language is needed that reflects the variability of interventions. As the established Business Process Model and Notation (BPMN) reaches its limits in terms of flexibility, the Case Management Model and Notation (CMMN) was considered as it addresses weakly structured processes.
Methods
To analyze the suitability of the modeling languages, BPMN and CMMN models of a Robot-Assisted Minimally Invasive Esophagectomy and Cochlea Implantation were derived and integrated into a situation recognition workflow. Test cases were used to contrast the differences and compare the advantages and disadvantages of the models concerning modeling, execution, and control. Furthermore, the impact on transferability was investigated.
Results
Compared to BPMN, CMMN allows flexibility for modeling intraoperative processes while remaining understandable. Although more effort and process knowledge are needed for execution and control within a situation recognition system, CMMN enables better transferability of the models and therefore the system. Concluding, CMMN should be chosen as a supplement to BPMN for flexible process parts that can only be covered insufficiently by BPMN, or otherwise as a replacement for the entire process.
Conclusion
CMMN offers the flexibility for variable, weakly structured process parts, and is thus suitable for surgical interventions. A combination of both notations could allow optimal use of their advantages and support the transferability of the situation recognition system.
Integrating tools and applications into a clinically useful system for individual continuous health data surveillance requires an architecture considering all relevant medical and technical conditions. Therefore, the requirements of an integrated system including a health app to collect and monitor sensor data to support personalized medicine are analyzed. The structure and behavior of the system are defined regarding the specific health use cases and scenarios. A vendor-independent architecture, which enables the collection of vital data from arbitrary wearables using a smartphone, is presented. The data is centrally managed and processed by attending physicians. The modular architecture allows the system to extend to new scenarios, data formats, etc. A prototypical implementation of the system shows the feasibility of the approach.
A clinically useful system for individual continuous health data monitoring needs an architecture that takes into account all relevant medical and technical conditions. The requirements for a health app to support such a system are collected, and a vendor independent architecture is designed that allows the collection of vital data from arbitrary wearables using a smartphone. A prototypical implementation for the main scenario shows the feasibility of the approach.
Die rasante Entwicklung der Sensortechnik im Endverbraucherbereich lässt einen klinischen Nutzen der verfügbaren dezentral erhobenen Daten aus dem Patientenalltag zur Überwachung des individuellen Gesundheitszustands vermuten. Zur Überprüfung dieser Vermutung ist die Bereitstellung einer entsprechenden Plattform in den klinischen Alltag erforderlich. Hierzu wird die bwHealthApp entwickelt, mit der sowohl die aktuelle Bandbreite als auch die Evolution der Sensortechnik auf die klinische Anwendung abbildbar ist. Mit dem flexiblen Entwurf lässt sich der klinische Nutzen für die personalisierte Medizin evaluieren. Außerdem bietet die bwHealthApp einen an Machbarkeit orientierten Diskussionsbeitrag zu offenen rechtlichen, regulatorischen und ethischen Fragestellungen der Digitalisierung in der Medizin in Deutschland.
Background/Aim: The aim of this study was the development of a new osteoconductivity index to determine the bone healing capacities of bone substitute materials (BSM) on the basis of 3D microcomputed tomographic (μ-CT) data. Materials and Methods: Sinus biopsies were used for the comparative analysis of the integration behavior of two xenogeneic BSM (cerabone® and Bio Oss®). 3D μ-CT and data sets from histomorphometrical measurements based on 2D histological slices were used to measure the bone-material-contact and the tissue distribution within the biopsies. The tissue reactions to both BSM were microscopically analyzed. Results: The 3D and 2D results of the osteoconductivity measurements showed comparable material-bone contacts for both BSM, but the 2D data were significantly lower. The same results were found when tissue distribution was measured in both groups. The histopathological analysis showed comparative tissue reactions in both BSM. Conclusion: Osteoconductivity index is a reliable measurement parameter for determining the healing capacities of BSM. The observed differences between both measurement methods could be assigned to the resolution capacity of μ-CT data that did not allow for a precise interface distinction between both BSM and bone tissue. Histomorphometrical data based on histological slides still allow for a more exact evaluation.
Intra-operative fluoroscopy-guided assistance system for transcatheter aortic valve implantation
(2014)
A new surgical assistance system has been developed to assist the correct positioning of the AVP during transapical TAVI. The developed assistance system automatically defines the target area for implanting the AVP under live 2-D fluoroscopy guidance. Moreover, this surgical assistance system works with low levels of contrast agent for the final deployment of AVP, reducing therefore long-term negative effects, such as renal failure in the elderly and high-risk patients.
Background and purpose: Transapical aortic valve replacement (TAVR) is a recent minimally invasive surgical treatment technique for elderly and high-risk patients with severe aortic stenosis. In this paper,a simple and accurate image-based method is introduced to aid the intra-operative guidance of TAVR procedure under 2-D X-ray fluoroscopy.
Methods: The proposed method fuses a 3-D aortic mesh model and anatomical valve landmarks with live 2-D fluoroscopic images. The 3-D aortic mesh model and landmarks are reconstructed from interventional X-ray C-arm CT system, and a target area for valve implantation is automatically estimated using these aortic mesh models.Based on template-based tracking approach, the overlay of visualized 3-D aortic mesh model, land-marks and target area of implantation is updated onto fluoroscopic images by approximating the aortic root motion from a pigtail catheter motion without contrast agent. Also, a rigid intensity-based registration algorithm is used to track continuously the aortic root motion in the presence of contrast agent.Furthermore, a sensorless tracking of the aortic valve prosthesis is provided to guide the physician to perform the appropriate placement of prosthesis into the estimated target area of implantation.
Results: Retrospective experiments were carried out on fifteen patient datasets from the clinical routine of the TAVR. The maximum displacement errors were less than 2.0 mm for both the dynamic overlay of aortic mesh models and image-based tracking of the prosthesis, and within the clinically accepted ranges. Moreover, high success rates of the proposed method were obtained above 91.0% for all tested patient datasets.
Conclusion: The results showed that the proposed method for computer-aided TAVR is potentially a helpful tool for physicians by automatically defining the accurate placement position of the prosthesis during the surgical procedure.
Tumorzellen on the move : mikrosystem-basierter Assay zur Untersuchung der Tumorzellen-Migration
(2016)
Die Invasion von Tumorzellen in umliegendes Gewebe und die Bildung von Metastasen transformieren einen lokal wachsenden Tumor in eine systemische und lebensbedrohliche Krankheit mit schlechter Prognose. Dabei spielt die aktive Migration der Tumorzellen eine entscheidende Rolle. Tumorzellen gelangen durch die aktive Zellbewegung in das Lymph- oder Blutsystem und breiten sich im Körper aus. Bei der Invasion in ein neues Organ migrieren die Zellen ebenfalls wieder in komplexer Weise durch das Gewebe und können schließlich dort Metastasen bilden. Auf Grund der enormen medizinischen Relevanz der Tumorzell-Invasion, wird die Bewegung von Tumorzellen seit Jahrzehnten unter Laborbedingungen umfassend untersucht und ist ein wichtiger Marker für die Aggressivität der Tumorzellen. Zur Bewegungsanalyse gibt es mehrere experimentelle und auch kommerziell erhältliche in-vitro Untersuchungsmethoden. Ziel des interdisziplinären Projektes „MigChip“ ist die Entwicklung, Herstellung und experimentelle Validierung eines Mikrofludik-Chips zur verbesserten, detailgenauen in-vitro Untersuchung der Tumorzellen-Migration.
Documentation of clinical processes, especially in the perioperative are, is a base requirement for quality of service. Nonetheless, the documentation is a burden for the medical staff since it distracts from the clinical core process. An intuitive and user-friendly documentation system could increase documentation quality and reduce documentation workload. The optimal system solution would know what happened and the person documenting the step would need a single “confirm” button. In many cases, such a linear flow of activities is given as long as only one profession (e.g. anaestesiology, scrub nurse) is considered, but even in such cases, there might be derivations from the linear process flow and further interaction is required.
This project aims to evaluate existing big data infrastructures for their applicability in the operating room to support medical staff with context-sensitive systems. Requirements for the system design were generated. The project compares different data mining technologies, interfaces, and software system infrastructures with a focus on their usefulness in the peri-operative setting. The lambda architecture was chosen for the proposed system design, which will provide data for both postoperative analysis and real-time support during surgery.