660 Technische Chemie
Refine
Document Type
- Journal article (22)
- Book chapter (16)
- Conference proceeding (5)
- Patent / Standard / Guidelines (4)
- Doctoral Thesis (3)
- Book (1)
- Review (1)
- Working Paper (1)
Is part of the Bibliography
- yes (53)
Institute
- Life Sciences (49)
- Texoversum (3)
- Technik (1)
Publisher
- Elsevier (21)
- Wiley (11)
- De Gruyter (3)
- CERN Data Centre (1)
- Druckerei & Verlagshaus Mainz (1)
- Hanser (1)
- IOP Publishing (1)
- MDPI (1)
- Sage Publishing (1)
- Springer (1)
A new two-dimensional fluorescence sensor system was developed for in-line monitoring of mammalian cell cultures. Fluorescence spectroscopy allows for the detection and quantification of naturally occurring intra- and extracellular fluorophores in the cell broth. The fluorescence signals correlate the the cells' current redox state and other relevant process parameters. Cell culture pretests with twelve different excitation wavelengths showed that only three wavelengths account for a vast majority of spectral variation. Accordingly, the newly developed device utilizes three high-power LEDs as excitation sources in combination with a back-thinned CCD-spectrometer for fluorescence detection.
Estimating molar solubility from the Hildebrand-Scott relation employing Hansen solubility parameters (HSP) is widely presumed a valid semi quantitative approach. To test this presumption and to determine quantitatively the inherent accuracy of such a solubility prognosis, l-ascorbic acid (LAA) was treated as an example of a commercially important solute. Analytical calculus and Monte Carlo (MC) simulation were performed for 20 common solvents with total HSP ranging from 14.5 to 33.0 (MPa)0.5 utilizing validated material data. It was found that, due to the uncertainty of the material data used in the calculations, the solubility prediction had a large scattering and, thus, a low precision.
Allyls
(2014)
This chapter addresses the importance and usage of the commercially low volume thermoset plastics group known as allyls. The three significant sub-elements of this group are poly(diallylphthalates), poly(diallylisophthalates), and poly(allyldiglycol carbonate). Chemistry, processing, and properties are also described. Allyl polymers are synthesized by radical polymerizations of allyl monomers that usually do not produce high-molecular-mass macromolecules. Therefore, only a few specific monomers can produce thermosetting materials. Diallyldiglycolcarbonate (CR-39) and diallylphthalates are the most significant examples that have considerably improved our everyday life.
Allyls
(2022)
This chapter addresses the importance and usage of the commercially low-volume thermoset plastics group known as allyls. The three significant subelements of this group are poly(diallylphthalates), poly(diallylisophthalates), and poly(allyldiglycol carbonate). Chemistry, processing, and properties are also described. Allyl polymers are synthesized by radical polymerizations of allyl monomers that usually do not produce high-molecular-mass macromolecules. Therefore only a few specific monomers can produce thermosetting materials. Diallyldiglycolcarbonate (CR-39) and diallylphthalates are the most significant examples that have considerably improved our everyday life.
An apparatus and method for analyzing a flow of material having an inlet region, a measurement range and an outlet region, and having a first diverter and a second diverter, and a deflection area, wherein in a first state of operation, the two diverters form a continuous first material flow space from the inlet region via the first diverter through the measurement range, via the second diverter to the outlet region, and in a second state of operation, form a continuous second material flow space from the inlet region via the first diverter through the deflection area, via the second diverter to the outlet region.
We report an investigation into the distribution of copper oxidation states in oxide films formed on the surfaces of technical copper. The oxide films were grown by thermal annealing at ambient conditions and studied using Auger depth profiling and UV–Vis spectroscopy. Both Auger and UV–Vis data were evaluated applying multivariate curve resolution (MCR). Both experimental techniques revealed that the growth of Cu2O dominates the initial ca. 40 nm of oxide films grown at 175 °C, while further oxide growth is dominated by CuO formation. The largely coincident results from both experimental approaches demonstrates the huge benefit of the application of UV–Vis spectroscopy in combination with MCR analysis, which provides access to information on chemical state distributions without the need for destructive sample analysis. Both approaches are discussed in detail.
Different sensor types using chemical and biochemical principles are described. The former are mainly gas sensors, the latter are applied especially to liquids. Those label-free direct detection methods are compared with applications where assays take advantage of labeled receptors.
Furthermore, selected applications in the area of gas sensors are discussed, and sensors for process control, point-of-care diagnostics, environmental analytics, and food analytics are reviewed. In addition, multiplexing approaches used in microplates and microarrays are described.
On account of the huge number of sensor types and the wide range of possible applications, only the most important ones are selected here.
Die kontinuierliche Erfassung von Qualitätsparametern ist eine zunehmende Anforderung in der Polymerextrusion. Die optische Spektroskopie kann diese Anforderung erfüllen, da sie neben der Farbe weitere Parameter wie beispielsweise chemische Eigenschaften, Trübungsgrad oder Partikelgröße erfasst. Dabei werden für Inline-Messungen im Extruder optische Sonden eingesetzt. Im laufenden Betrieb bilden sich Ablagerungen auf den Sondenfenstern. Dieser Beitrag präsentiert ein neues Cleaning in Place Konzept, mit dessen Hilfe die Fenster auch während der Produktion ohne Unterbrechung gereinigt werden können. Auch die Kalibrierung der Messtechnik ist dabei möglich. Das verhindert Rüstzeiten und sichert eine kontinuierliche Inline-Messung.
Comments on “Solubility parameter of chitin and chitosan”, Carbohydrate Polymers 36 (1998) 121–127
(2017)
Results on the solubility parameters of chitin and chitosan presented in the paper DOI: 10.1016/S0144-8617(98)00020-4 were recalculated and data evaluation was redone. A number of misprints, erroneous calculations and data evaluations were found with respect to Hansen as well as total solubility parameters as derived according to group contribution methods by Hoftyzer-Van Krevelen and Hoy’s system. Revised numerical data are presented.