Thermoplastic polymers like ethylene-octene copolymer (EOC) may be grafted with silanes via reactive extrusion to enable subsequent crosslinking for advanced biomaterials manufacture. However, this reactive extrusion process is difficult to control and it is still challenging to reproducibly arrive at well-defined products. Moreover, high grafting degrees require a considerable excess of grafting reagent. A large proportion of the silane passes through the process without reacting and needs to be removed at great expense by subsequent purification. This results in unnecessarily high consumption of chemicals and a rather resource-inefficient process. It is thus desired to be able to define desired grafting degrees with optimum grafting efficiency by means of suitable process control. In this study, the continuous grafting of vinyltrimethoxysilane (VTMS) on ethylene-octene copolymer (EOC) via reactive extrusion was investigated. Successful grafting was verified and quantified by 1H-NMR spectroscopy. The effects of five process parameters and their synergistic interactions on grafting degree and grafting efficiency were determined using a face-centered experimental design (FCD). Response surface methodology (RSM) was applied to derive a causal process model and define process windows yielding arbitrary grafting degrees between <2 and >5% at a minimum waste of grafting agent. It was found that the reactive extrusion process was strongly influenced by several second-order interaction effects making this process difficult to control. Grafting efficiencies between 75 and 80% can be realized as long as grafting degrees <2% are admitted.
Here, we report the continuous peroxide-initiated grafting of vinyltrimethoxysilane (VTMS) onto a standard polyolefin by means of reactive extrusion to produce a functionalized liquid ethylene propylene copolymer (EPM). The effects of the process parameters governing the grafting reaction and their synergistic interactions are identified, quantified and used in a mathematical model of the extrusion process. As process variables the VTMS and peroxide concentrations and the extruder temperature setting were systematically studied for their influence on the grafting and the relative grafting degree using a face-centered central composite design (FCD). The grafting degree was quantified by 1H NMR spectroscopy. Response surface methodology (RSM) was used to calculate the most efficient grafting process in terms of chemical usage and graft yield. With the defined processing window, it was possible to make precise predictions about the grafting degree with at the same time highest possible relative degree of grafting.
The chemical synthesis of polysiloxanes from monomeric starting materials involves a series of hydrolysis, condensation and modification reactions with complex monomeric and oligomeric reaction mixtures. Real-time monitoring and precise process control of the synthesis process is of great importance to ensure reproducible intermediates and products and can readily be performed by optical spectroscopy. In chemical reactions involving rapid and simultaneous functional group transformations and complex reaction mixtures, however, the spectroscopic signals are often ambiguous due to overlapping bands, shifting peaks and changing baselines. The univariate analysis of individual absorbance signals is hence often only of limited use. In contrast, batch modelling based on the multivariate analysis of the time course of principal components (PCs) derived from the reaction spectra provides a more efficient tool for real time monitoring. In batch modelling, not only single absorbance bands are used but information over a broad range of wavelengths is extracted from the evolving spectral fingerprints and used for analysis. Thereby, process control can be based on numerous chemical and morphological changes taking place during synthesis. “Bad” (or abnormal) batches can quickly be distinguished from “normal” ones by comparing the respective reaction trajectories in real time. In this work, FTIR spectroscopy was combined with multivariate data analysis for the in-line process characterization and batch modelling of polysiloxane formation. The synthesis was conducted under different starting conditions using various reactant concentrations. The complex spectral information was evaluated using chemometrics (principal component analysis, PCA). Specific spectral features at different stages of the reaction were assigned to the corresponding reaction steps. Reaction trajectories were derived based on batch modelling using a wide range of wavelengths. Subsequently, complexity was reduced again to the most relevant absorbance signals in order to derive a concept for a low-cost process spectroscopic set-up which could be used for real-time process monitoring and reaction control.
Vitamin E (VitE) additives are important in treating osteoarthritis inclusive cartilage regeneration due to their antioxidant and anti-inflammatory properties. The present research study focuses on the ability of biological antioxidant VitE (alpha-tocopherol isoform) to reduce or minimize oxidative degradation of soft implantable polyurethane (PU) elastomers after extended periods of time (5 months) in vitro. The effect of the oxidation storage media on the morphology of the segmented PUs was evaluated by mechanical softening, crystallization and melting behavior of both soft and hard segments (SS, HS) using dynamic mechanical analysis (DMA). Bulk mechanical properties of the potential implant materials during ageing were predicted from comprehensive mechanical testing of the biomaterials under tension and compression cyclic loads. 5-months in vitro data suggest that the prepared siloxane-poly(carbonate urethane) formulations have sufficient resistance against degradation to be suitable materials for chondral long term bio-stable implants. Most importantly, the positive effect of incorporating VitE (0.5 or 1.0% w/w) as bio-antioxidant and lubricant on the bio-stability was observed for all PU types. VitE-additives protected the surface layer from erosion and cracking during chemical oxidation in vitro as well as from thermal oxidation during extrusion re-processing.
Polyurethane-bases block copolymers (TPCUs) are block-copolymers with systematically varied soft and hard segments. They have been suggested to serve as material for chondral implants in joint regeneration. Such applications may require the adhesion of chondrocytes to the implant surface, facilitating cell growth while keeping their phenotype. Thus, aims of this work were (1) to modify the surface of soft biostable polyurethane-based model implants (TPCU and TSiPCU) with high-molecular weight hyaluronic acid (HA) using an optimized multistep strategy of immobilization, and (2) to evaluate bioactivity of the modified TPCUs in vitro. Our results show no cytotoxic potential of the TPCUs. HAbioactive molecules (Mw =700kDa) were immobilized onto the polyurethane surface via polyethylenimine (PEI) spacers, and modifications were confirmed by several characterization methods. Tests with porcine chondrocytes indicated the potential of the TPCU-HA for inducing enhanced cell proliferation.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms (S) mit einem Einlassbereich (E), einem Messbereich (M) und einen Auslassbereich (A) sowie mit einer ersten Weiche (W1) und einer zweiten Weiche (W2) und einem Umlenkbereich (U), wobei die beiden Weichen (W1, W2) in einem ersten Schaltzustand (Z1) einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Messbereich (M) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Umlenkbereich (U) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms S mit einem Einlassbereich E, einem Messbereich M und einen Auslassbereich A sowie mit einer ersten Weiche W1 und einer zweiten Weiche W2 und einem Umlenkbereich U, wobei die beiden Weichen W1, W2 in einem ersten Schaltzustand Z1 einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Messbereich M über die zweite Weiche W2 bis zum Auslassbereich A ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Umkenkbereich U über die zweite Weiche W2 bis zum Auslassbereich A ausbilden.
An apparatus and method for analyzing a flow of material having an inlet region, a measurement range and an outlet region, and having a first diverter and a second diverter, and a deflection area, wherein in a first state of operation, the two diverters form a continuous first material flow space from the inlet region via the first diverter through the measurement range, via the second diverter to the outlet region, and in a second state of operation, form a continuous second material flow space from the inlet region via the first diverter through the deflection area, via the second diverter to the outlet region.
A series of novel biomedical TPCUs with different percentages of hard segment and a silicone component in the soft segment were synthesized in a multi stage one-pot method. The kinetic profiles of the urethane formation in TPCU-based copolymer systems were monitored by rheological, in line FTIR spectroscopic (React IR) and real-time calorimetric (RC1) methods. This process-analytically monitored multi step synthesis was successfully used to optimize the production of medical-grade TPCU elastomers on preparative scale (in lots of several kg) with controlled molecular structure and mechanical properties. Various surface and bulk analytical methods as well as systematic studies of the mechanic response of the elastomer end-products towards compression and tensile loading were used to estimate the bio-stability of the prepared TPCUs in vitro after 3 months. The tests suggested that high bio-stability of all polyurethane formulations using accelerating in vitro test can be attributed to the synthetic design as well as to the specific techniques used for specimen preparation, namely: (1) the annealing for reducing residual polymer surface stress and preventing IES, (2) stabilization of the morphology by long time storage of the specimens after processing before being immersed in the test liquids, (3) purification by extraction to remove the shot chain oligomers which are the most susceptible to degradation. All mechanical tests were performed on cylindrical and circular disc specimens for modelling the thickness of the meniscus implants under application-relevant stress conditions.