Refine
Document Type
- Journal article (29)
- Book (2)
- Book chapter (2)
- Conference proceeding (1)
Is part of the Bibliography
- yes (34)
Institute
- Life Sciences (34) (remove)
Publisher
- Springer (34) (remove)
Ecuador, traditionally an agricultural based economy, has a great potential for valorizing their industrial residues. This study, presents a techno-economic analysis for applying a novel biomass oxidation method to produce formic and acetic acids from coffee husk residues in Machala, Ecuador. The analysis determined that the time of return of investment was lower than 5 years, making this project economically feasible, when producing approx. 1000 tons of formic acid per year, which is enough for supplying the Ecuadorian market. This production, would reduce imports costs and develop the chemical industry in the country.
Glioblastoma WHO IV belongs to a group of brain tumors that are still incurable. A promising treatment approach applies photodynamic therapy (PDT) with hypericin as a photosensitizer. To generate a comprehensive understanding of the photosensitizer-tumor interactions, the first part of our study is focused on investigating the distribution and penetration behavior of hypericin in glioma cell spheroids by fluorescence microscopy. In the second part, fluorescence lifetime imaging microscopy (FLIM) was used to correlate fluorescence lifetime (FLT) changes of hypericin to environmental effects inside the spheroids. In this context, 3D tumor spheroids are an excellent model system since they consider 3D cell–cell interactions and the extracellular matrix is similar to tumors in vivo. Our analytical approach considers hypericin as probe molecule for FLIM and as photosensitizer for PDT at the same time, making it possible to directly draw conclusions of the state and location of the drug in a biological system. The knowledge of both state and location of hypericin makes a fundamental understanding of the impact of hypericin PDT in brain tumors possible. Following different incubation conditions, the hypericin distribution in peripheral and central cryosections of the spheroids were analyzed. Both fluorescence microscopy and FLIM revealed a hypericin gradient towards the spheroid core for short incubation periods or small concentrations. On the other hand, a homogeneous hypericin distribution is observed for long incubation times and high concentrations. Especially, the observed FLT change is crucial for the PDT efficiency, since the triplet yield, and hence the O2 activation, is directly proportional to the FLT. Based on the FLT increase inside spheroids, an incubation time 30 min is required to achieve most suitable conditions for an effective PDT.
Characterization of low density polyethylene greenhouse films during the composting of rose residues
(2022)
This study presents an evaluation of a potential alternative to plastic degradation in the form of organic composting. It stems from the urgent need of finding solutions to the plastic residues and focuses on the compost-based degradation of greenhouse film covers in an important rose exporter company in Ecuador. Thus, this study analyzes the physical, chemical, and biological changes of rose wastes composting, and also evaluates the stability of new and aged agricultural plastic under these conditions. Interestingly, results of compost characterization show a slow degradation rate of organic matter and total organic carbon, along with a significant increase in pH and rise of bacterial populations. However, the results demonstrate that despite these findings, composting conditions had no significant influence on plastic degradation, and while deterioration of aged plastic samples was reported in some tests, it may be the result of environmental conditions and a prolonged exposure to solar radiation. Importantly, these factors could facilitate the adhesion of microorganisms and promote plastic biodegradation. Hence, it is encouraged for future studies to analyze the ecotoxicity of plastics in the compost, as well as isolate, identify, and evaluate the possible biodegradative potential of these microorganisms as an alternative to plastic waste management.
The early detection of head and neck cancer is a prolonged challenging task. It requires a precise and accurate identification of tissue alterations as well as a distinct discrimination of cancerous from healthy tissue areas. A novel approach for this purpose uses microspectroscopic techniques with special focus on hyperspectral imaging (HSI) methods. Our proof-of-principle study presents the implementation and application of darkfield elastic light scattering spectroscopy (DF ELSS) as a non-destructive, high-resolution, and fast imaging modality to distinguish lingual healthy from altered tissue regions in a mouse model. The main aspect of our study deals with the comparison of two varying HSI detection principles, which are a point-by-point and line scanning imaging, and whether one might be more appropriate in differentiating several tissue types. Statistical models are formed by deploying a principal component analysis (PCA) with the Bayesian discriminant analysis (DA) on the elastic light scattering (ELS) spectra. Overall accuracy, sensitivity, and precision values of 98% are achieved for both models whereas the overall specificity results in 99%. An additional classification of model-unknown ELS spectra is performed. The predictions are verified with histopathological evaluations of identical HE-stained tissue areas to prove the model’s capability of tissue distinction. In the context of our proof-of-principle study, we assess the Pushbroom PCA-DA model to be more suitable for tissue type differentiations and thus tissue classification. In addition to the HE-examination in head and neck cancer diagnosis, the usage of HSI-based statistical models might be conceivable in a daily clinical routine.
In the era of precision medicine, digital technologies and artificial intelligence, drug discovery and development face unprecedented opportunities for product and business model innovation, fundamentally changing the traditional approach of how drugs are discovered, developed and marketed. Critical to this transformation is the adoption of new technologies in the drug development process, catalyzing the transition from serendipity-driven to data-driven medicine. This paradigm shift comes with a need for both translation and precision, leading to a modern Translational Precision Medicine approach to drug discovery and development. Key components of Translational Precision Medicine are multi-omics profiling, digital biomarkers, model-based data integration, artificial intelligence, biomarker-guided trial designs and patient-centric companion diagnostics. In this review, we summarize and critically discuss the potential and challenges of Translational Precision Medicine from a cross-industry perspective.
Programmable nano-bio interfaces driven by tuneable vertically configured nanostructures have recently emerged as a powerful tool for cellular manipulations and interrogations. Such interfaces have strong potential for ground-breaking advances, particularly in cellular nanobiotechnology and mechanobiology. However, the opaque nature of many nanostructured surfaces makes non-destructive, live-cell characterization of cellular behavior on vertically aligned nanostructures challenging to observe. Here, a new nanofabrication route is proposed that enables harvesting of vertically aligned silicon (Si) nanowires and their subsequent transfer onto an optically transparent substrate, with high efficiency and without artefacts. We demonstrate the potential of this route for efficient live-cell phase contrast imaging and subsequent characterization of cells growing on vertically aligned Si nanowires. This approach provides the first opportunity to understand dynamic cellular responses to a cell-nanowire interface, and thus has the potential to inform the design of future nanoscale cellular manipulation technologies.
The article analyzes experimentally and theoretically the influence of microscope parameters on the pinhole-assisted Raman depth profiles in uniform and composite refractive media. The main objective is the reliable mapping of deep sample regions. The easiest to interpret results are found with low magnification, low aperture, and small pinholes. Here, the intensities and shapes of the Raman signals are independent of the location of the emitter relative to the sample surface. Theoretically, the results can be well described with a simple analytical equation containing the axial depth resolution of the microscope and the position of the emitter. The lower determinable object size is limited to 2–4 μm. If sub-micrometer resolution is desired, high magnification, mostly combined with high aperture, becomes necessary. The signal intensities and shapes depend now in refractive media on the position relative to the sample surface. This aspect is investigated on a number of uniform and stacked polymer layers, 2–160 μm thick, with the best available transparency. The experimental depth profiles are numerically fitted with excellent accuracy by inserting a Gaussian excitation beam of variable waist and fill fraction through the focusing lens area, and by treating the Raman emission with geometric optics as spontaneous isotropic process through the lens and the variable pinhole, respectively. The intersectional area of these two solid angles yields the leading factor in understanding confocal (pinhole-assisted) Raman depth profiles.
This book describes the current state of the art in integrated ring resonators, covering more than two decades in the development of this exciting device. It discusses in depth one of the most fascinating and versatile integrated optical filters, providing readers with a panoramic view spanning from design and simulation to implementation in various material systems. Written by authors with extensive experience in both academia and industry, this second edition offers a much-needed, major update as interest in integrated ring resonators undergoes a global revival. The new edition includes a comprehensive technological update, and a timely discussion of recent advances in new application areas, such as optofluidics and microfluidics, telecom operations and biosensors. This aptly named compendium is the ideal guide for researchers and engineers looking to review the field as a whole while exploring several of its possible and exciting future trajectories.
Exogenous factors of influence on exhaled breath analysis by ion-mobility spectrometry (MCC/IMS)
(2019)
The interpretation of exhaled breath analysis needs to address to the influence of exogenous factors, especially to a transfer of confounding analytes by the test persons. A test person who was exposed to a disinfectant had exhaled breath analysis by MCC/IMS (Bioscout®) after different time intervals. Additionally, a new sampling method with inhalation of synthetic air before breath analysis was tested. After exposure to the disinfectant, 3-Pentanone monomer, 3-Pentanone dimer, Hexanal, 3-Pentanone trimer, 2-Propanamine, 1-Propanol, Benzene, Nonanal showed significantly higher intensities, in exhaled breath and air of the examination room, compared to the corresponding baseline measurements. Only one ingredient of the disinfectant (1-Propanol) was identical to the 8 analytes. Prolonging the time intervals between exposure and breath analysis showed a decrease of their intensities. However, the half-time of the decrease was different. The inhalation of synthetic air - more than consequently airing the examination room with fresh air - reduced the exogenous and also relevant endogenous analytes, leading to a reduction and even changing polarity of the alveolar gradient. The interpretation of exhaled breath needs further knowledge about the former residence of the proband and the likelihood and relevance of the inhalation of local, site-specific and confounding exogenous analytes by him. Their inhalation facilitates a transfer to the examination room and a detection of high concentrations in room air and exhaled breath, but also the exhalation of new analytes. This may lead to a misinterpretation of these analytes as endogenous resp. disease-specific ones.
Standardisation of breath sampling is important for application of breath analysis in clinical settings. By studying the effect of room airing on indoor and breath analytes and by generating time series of room air with different sampling intervals we sought to get further insights into room air metabolism, to detect the relevance of exogenous VOCs and to make conclusions about their consideration for the interpretation of exhaled breath. Room air and exhaled breath of a healthy subject were analysed before and after room airing. Furthermore a time series of room air with doors and windows closed was taken over 84 h by an automatic sampling every 180 min. A second times series studied room air analytes over 70 h with samples taken every 16.5 min. For breath and room air measurements an IMS coupled to a multi-capillary column (IMS/MCC) [Bio-Scout® - B&S Analytik GmbH, Dortmund, Germany] was used. The peaks were characterized using the Software Visual Now (B&S Analytik, Dortmund Germany) and identified using the software package MIMA (version 1.1, provided by the Max Planck Institute for Informatics, Saarbrücken, Germany) and the database 20160426_SubstanzDbNIST_122 (B & S Analytik GmbH, Dortmund, Germany). In the morning 4 analytes (Decamethylcylopentasiloxane [541-02-6]; Pentan-2-one [107-87-9] – Dimer; Hexan-1-al [66-25-1]; Pentan-2-one [107-87-9]) – Monomer showed high intensities in the room air and exhaled breath. They were significantly but not equally reduced by room airing. The time series about 84 h showed a time dependent decrease of analytes (limonen-monomer and -dimer; Decamethylcylopentasiloxane, Butan-1-ol, Butan-1-ol) as well as increase (Pentan-2-one [107-87-9] – Dimer). Shorter sampling intervals exhibited circadian variations of analyte concentrations for many analytes. Breath sampling in the morning needs room airing before starting. Then the variation of the intensity of indoor analytes can be kept small. The time series of indoor analytes show, that their intensities have a different behaviour, with time dependent declines, constant increases and circadian variations, dependent on room airing. This has implications on the breath sampling procedure and the intrepretation of exhaled breath.