Refine
Document Type
- Journal article (49)
- Book (6)
- Book chapter (5)
- Doctoral Thesis (4)
- Patent / Standard / Guidelines (4)
- Conference proceeding (1)
Has full text
- no (69) (remove)
Is part of the Bibliography
- yes (69)
Institute
- Life Sciences (69) (remove)
Publisher
- Elsevier (23)
- IOP Publishing (7)
- Royal Society of Chemistry (6)
- Springer (5)
- CRC Press (3)
- The Royal Society of Chemistry (3)
- De Gruyter (2)
- DUZ Verlags- und Medienhaus GmbH (1)
- Druckerei & Verlagshaus Mainz (1)
- Gupta (1)
Influence of the respirator on volatile organic compounds : an animal study in rats over 24 hours
(2015)
Long-term animal studies are needed to accomplish measurements of volatile organic compounds (VOCs) for medical diagnostics. In order to analyze the time course of VOCs, it is necessary to ventilate these animals. Therefore, a total of 10 male Sprague–Dawley rats were anaesthetized and ventilated with synthetic air via tracheotomy for 24 h. An ion mobility spectrometry coupled to multi-capillary columns (MCC–IMS) was used to analyze the expired air. To identify background contaminations produced by the respirator itself, six comparative measurements were conducted with ventilators only. Overall, a number of 37 peaks could be detected within the positive mode. According to the ratio peak intensity rat/ peak intensity ventilator blank, 22 peaks with a ratio >1.5 were defined as expired VOCs, 12 peaks with a ratio between 0.5 and 1.5 as unaffected VOCs, and three peaks with a ratio <0.5 as resorbed VOCs. The peak intensity of 12 expired VOCs changed significantly during the 24 h measurement. These results represent the basis for future intervention studies. Notably, online VOC analysis with MCC–IMS is possible over 24 h in ventilated rats and allows different experimental approaches.
The properties of polyelectrolyte multilayers are ruled by the process parameters employed during self-assembly. This is the first study in which a design of experiment approach was used to validate and control the production of ultrathin polyelectrolyte multilayer coatings by identifying the ranges of critical process parameters (polyelectrolyte concentration, ionic strength and pH) within which coatings with reproducible properties (thickness, refractive index and hydrophilicity) are created. Mathematical models describing the combined impact of key process parameters on coatings properties were developed demonstrating that only ionic strength and pH affect the coatings thickness, but not polyelectrolyte concentration. While the electrolyte concentration had a linear effect, the pH contribution was described by a quadratic polynomial. A significant contribution of this study is the development of a new approach to estimate the thickness of polyelectrolyte multilayer nanofilms by quantitative rhodamine B staining, which might be useful in all cases when ellipsometry is not feasible due to the shape complexity or small size of the coated substrate. The novel approach proposed here overcomes the limitations of known methods as it offers a low spatial sampling size and the ability to analyse a wide area without restrictions on the chemical composition and shape of the substrate.
Herein the optimization of the physicochemical properties and surface biocompatibility of polyelectrolyte multilayers of the natural, biocompatible and biodegradable, linear polysaccharides hyaluronan and chitosan by Hofmeister anions was systematically investigated. We demonstrated that there is an interconnection between the bulk and surface properties of HA/Chi multilayers both varying in accordance with the arrangement of the anions in the Hofmeister series. Kosmotropic anions increased the hydration, thickness, micro- and macro-roughness, and hydrophilicity and improved the biocompatibility of the films by reduction (2 orders of magnitude) of the films stiffness and complete anti-thrombogenicity.
We report the temperature dependence of metal-enhanced fluorescence (MEF) of individual photosystem I (PSI) complexes from Thermosynechococcus elongatus (T. elongatus) coupled to gold nanoparticles (AuNPs). A strong temperature dependence of shape and intensity of the emission spectra is observed when PSI is coupled to AuNPs. For each temperature, the enhancement factor (EF) is calculated by comparing the intensity of individual AuNP-coupled PSI to the mean intensity of ‘uncoupled’ PSI. At cryogenic temperature (1.6 K) the average EF was 4.3-fold. Upon increasing the temperature to 250 K the EF increases to 84-fold. Single complexes show even higher EFs up to 441.0-fold. At increasing temperatures the different spectral pools of PSI from T. elongatus become distinguishable. These pools are affected differently by the plasmonic interactions and show different enhancements. The remarkable increase of the EFs is explained by a rate model including the temperature dependence of the fluorescence yield of PSI and the spectral overlap between absorption and emission spectra of AuNPs and PSI, respectively.
Unprecedented formation of sterically stabilized phospholipid liposomes of cuboidal morphology
(2021)
Sterically stabilized phospholipid liposomes of unprecedented cuboid morphology are formed upon introduction in the bilayer membrane of original polymers, based on polyglycidol bearing a lipid-mimetic residue. Strong hydrogen bonding in the polyglycidol sublayers creates attractive forces, which, facilitated by fluidization of the membrane, bring about the flattening of the bilayers and the formation of cuboid vesicles.
The number of publications in the field of breath analysis using different types of ion mobility spectrometers (IMS) has increased over the last few years. In this paper, the publications between 2010 and 2013 are reviewed with respect to different types of IMS such as differential mobility spectrometers, high-field asymmetric waveform ion mobility spectrometers and multi-capillary columns coupled to conventional IMS. The analytes detected by IMS and declared with significance to a specific medical question were considered further with respect to medical and analytical questions. In total, 42 different analytes were found to be detected using IMS on a high significance level and were compared to findings using other analytical methods with respect to the individual analyte.
Long-term stability of membranes in membrane distillation operation is a problem nowadays which prevents the industrial breakthrough of this separation process. Fouling or slow pore wetting are the basic reasons for this.
Membrane distillation membranes were made by NIPS process rendering the membrane asymmetrically to achieve low permeation resistance and pores which can be over coated with polyelectrolyte polymers thus leading to thermopervaporation membranes. Those membranes prohibit pore wetting and may strongly reduce resorption of organic substances on for membrane distillation typically used hydrophobic surfaces thus leading to longterm operation stability in dewatering including stable membrane cleaning.
Asymmetric PVDF membranes have been coated with cation exchange polyelectrolyte leading to a very thin, defect-free layer which has a high permeation rate for water due to the domain structure of phase-separated hydrophilic and hydrophobic three-dimensional structures.
An apparatus and method for analyzing a flow of material having an inlet region, a measurement range and an outlet region, and having a first diverter and a second diverter, and a deflection area, wherein in a first state of operation, the two diverters form a continuous first material flow space from the inlet region via the first diverter through the measurement range, via the second diverter to the outlet region, and in a second state of operation, form a continuous second material flow space from the inlet region via the first diverter through the deflection area, via the second diverter to the outlet region.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms S mit einem Einlassbereich E, einem Messbereich M und einen Auslassbereich A sowie mit einer ersten Weiche W1 und einer zweiten Weiche W2 und einem Umlenkbereich U, wobei die beiden Weichen W1, W2 in einem ersten Schaltzustand Z1 einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Messbereich M über die zweite Weiche W2 bis zum Auslassbereich A ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich E über die erste Weiche W1 durch den Umkenkbereich U über die zweite Weiche W2 bis zum Auslassbereich A ausbilden.
Die Erfindung betrifft eine Vorrichtung und Verfahren zur Analyse eines Materialstroms (S) mit einem Einlassbereich (E), einem Messbereich (M) und einen Auslassbereich (A) sowie mit einer ersten Weiche (W1) und einer zweiten Weiche (W2) und einem Umlenkbereich (U), wobei die beiden Weichen (W1, W2) in einem ersten Schaltzustand (Z1) einen durchgängigen ersten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Messbereich (M) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden und in einem zweiten Schaltzustand einen durchgängigen zweiten Materialdurchströmungsraum vom Einlassbereich (E) über die erste Weiche (W1) durch den Umlenkbereich (U) über die zweite Weiche (W2) bis zum Auslassbereich (A) ausbilden.
Here, we report the continuous peroxide-initiated grafting of vinyltrimethoxysilane (VTMS) onto a standard polyolefin by means of reactive extrusion to produce a functionalized liquid ethylene propylene copolymer (EPM). The effects of the process parameters governing the grafting reaction and their synergistic interactions are identified, quantified and used in a mathematical model of the extrusion process. As process variables the VTMS and peroxide concentrations and the extruder temperature setting were systematically studied for their influence on the grafting and the relative grafting degree using a face-centered central composite design (FCD). The grafting degree was quantified by 1H NMR spectroscopy. Response surface methodology (RSM) was used to calculate the most efficient grafting process in terms of chemical usage and graft yield. With the defined processing window, it was possible to make precise predictions about the grafting degree with at the same time highest possible relative degree of grafting.
Ion Mobility Spectrometry (IMS) is a widely used and `well-known’ technique of ion separation in the gaseous phase based on the differences in ion mobilities under an electric field. All IMS instruments operate with an electric field that provides space separation, but some IMS instruments also operate with a drift gas flow that provides also a temporal separation. In this review we will summarize the current IMS instrumentation. IMS techniques have received an increased interest as new instrumentation and have become available to be coupled with mass spectrometry (MS). For each of the eight types of IMS instruments reviewed it is mentioned whether they can be hyphenated with MS and whether they are commercially available. Finally, out of the described devices, the six most-consolidated ones are compared. The current review article is followed by a companion review article which details the IMS hyphenated techniques (mainly gas chromatography and mass spectrometry) and the factors that make the data from an IMS device change as a function of device parameters and sampling conditions. These reviews will provide the reader with an insightful view of the main characteristics and aspects of the IMS technique.
Ion Mobility Spectrometry (IMS) is a widely used and ‘well-known’ technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique.
The transmembrane Ca2+ − activated Cl− channel - human bestrophin-1 (hBest1) is expressed in retinal pigment epithelium and mutations of BEST1 gene cause ocular degenerative diseases colectivelly referred to as “bestrophinopathies”. A large number of genetical, biochemical, biophysical and molecular biological studies have been performed to understand the relationship between structure and function of the hBest1 protein and its pathophysiological significance. Here, we review the current understanding of hBest1 surface organization, interactions with membrane lipids in model membranes, and its association with microdomains of cellular membranes. These highlights are significant for modulation of channel activity in cells.
Employing diffuse reflection ultraviolet visible (UV–Vis) spectroscopy we developed an approach that is capable to quantitatively determine flux residues on a technical copper surface. The technical copper surface was soldered with a no-clean flux system of organic acids. By a post-solder cleaning step with different cleaning parameters, various levels of residues were produced. The surface was quantitatively and qualitatively characterized using X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), Fourier transform infrared spectroscopy (FTIR) and diffuse reflection UV–Vis spectroscopy. With the use of a multivariate analysis (MVA) we examined the UV–Vis data to create a correlation to the carbon content on the surface. The UV–Vis data could be discriminated for all groups by their level of organic residues. Combined with XPS the data were evaluated by a partial least squares (PLS) regression to establish a model. Based on this predictive model, the carbon content was calculated with an absolute error of 2.7 at.%. Due to the high correlation of predictive model, the easy-to-use measurement and the evaluation by multivariate analysis the developed method seems suitable for an online monitoring system. With this system, flux residues can be detected in a manufacturing cleaning process of technical surfaces after soldering.
High-performance liquid chromatography is one of the most important analytical tools for the identification and separation of substances. The efficiency of this method is largely determined by the stationary phase of the columns. Although monodisperse mesoporous silica microspheres (MPSM) represent a commonly used material as stationary phase their tailored preparation remains challenging. Here we report on the synthesis of four MPSMs via the hard template method. Silica nanoparticles (SNPs) which form the silica network of the final MPSMs were generated in situ from tetraethyl orthosilicate (TEOS) in the presence of (3-aminopropyl) triethoxysilane (APTES) functionalized p(GMA-co-EDMA) as hard template. Methanol, ethanol, 2-propanol, and 1-butanol were applied as solvents to control the size of the SNPs in the hybrid beads (HB). After calcination, MPSMs with different sizes, morphology and pore properties were obtained and characterized by scanning electron microscopy, nitrogen adsorption and desorption measurements, thermogravimetric analysis, solid state NMR and DRIFT IR spectroscopy. Interestingly, the 29Si NMR spectra of the HBs show T and Q group species which suggests that there is no covalent linkage between the SNPs and the template. The MPSMs were functionalized with trimethoxy (octadecyl) silane and used as stationary phases in reversed-phase chromatography to separate a mixture of eleven different amino acids. The separation characteristics of the MPSMs strongly depend on their morphology and pore properties which are controlled by the solvent during the preparation of the MPSMs. Overall, the separation behavior of the best phases is comparable with those of commercially available columns. The phases even achieve faster separation of the amino acids without loss of quality.
Concrete is significant for construction. A problem in application is the appearance of cracks that will damage its strength. An autogenous crack-healing mechanism based on bacteria receives increasing attention in recent years. The bacteria are able to form calcium carbonate (CaCO3) precipitations in suitable conditions to protect and reinforce the concrete. However, a large number of spores are crushed in aged specimens, resulting in a loss of viability. A new kind of hydrogel crosslinked by alginate, chitosan and calcium ions was introduced in this study. It was observed that the addition of chitosan improved the swelling properties of calcium alginate. Opposite pH response to calcium alginate was observed when the chitosan content in the solution reached 1.0%. With an addition of 1.0% chitosan in hydrogel beads, 10.28% increase of compressive strength and 13.79% increase of flexural strength to the control were observed. The results reveal self-healing properties of concretes. A healing crack of 4 cm length and 1 mm width was observed when using cement PO325, with the addition of bacterial spores (2.54–3.07 × 105/cm3 concrete) encapsulated by hydrogel containing no chitosan.
This book investigates and highlights the most critical challenges the pharmaceutical industry faces in an increasingly competitive environment of inflationary R&D investments and tightening cost control pressures. The authors present three sources of pharmaceutical innovation: new management methods in the drug development pipeline; new technologies as enablers for cutting-edge R&D; and new forms of cooperation and internationalization, such as open innovation in the early phases of R&D. New models and methods are illustrated with cases from Europe, the US, and Asia. This third fully revised edition was expanded to reflect the latest updates in open and collaborative innovation, the greater strategic importance of venture capital and early stage investments, and the new range of emerging technologies now being put to use in pharmaceutical innovation.
The surface properties of human meibomian lipids (MGS), the major constituent of the tear film (TF) lipid layer, are of key importance for TF stability. The dynamic interfacial properties of films by MGS from normal eyes (nMGS) and eyes with meibomian gland dysfunction (dMGS) were studied using a Langmuir surface balance. The behavior of the samples during dynamic area changes was evaluated by surface pressure–area isotherms and isocycles. The surface dilatational rheology of the films was examined in the frequency range 10−5 to 1 Hz by the stress-relaxation method. A significant difference was found, with dMGS showing slow viscosity-dominated relaxation at 10−4 to 10−3 Hz, whereas nMGS remained predominantly elastic over the whole range. A Cole–Cole plot revealed two characteristic processes contributing to the relaxation, fast (on the scale of characteristic time τ < 5 s) and slow (τ > 100 s), the latter prevailing in dMGS films. Brewster angle microscopy revealed better spreading of nMGS at the air–water interface, whereas dMGS layers were non-uniform and patchy. The distinctions in the interfacial properties of the films in vitro correlated with the accelerated degradation of meibum layer pattern at the air–tear interface and with the decreased stability of TF in vivo. These results, and also recent findings on the modest capability of meibum to suppress the evaporation of the aqueous subphase, suggest the need for a re-evaluation of the role of MGS. The probable key function of meibomian lipids might be to form viscoelastic films capable of opposing dilation of the air–tear interface. The impact of temperature on the meibum surface properties is discussed in terms of its possible effect on the normal structure of the film.
We investigate the toxicity of different types and sizes of microplastic particles (0.3–4 mm) under different conditions (new particles, aged particles with biofilm, and particles with adsorbed Tributyltin) on the freshwater amphipod Gammarus fossarum in 3-week exposures. All types of plastic particles, which were randomly taken up to a small extent, were mostly Polyphenylenoxide, Polybutylentherephthalate and Polypropylene, with particles < 1 mm in size. Plastic particles did not affect the feeding and locomotory behaviour of gammarids, and there was no strong difference between pristine plastic particles and aged particles with biofilm. Mortality tended to be higher compared with the control. Tributyltinhydride (TBTH) adsorbed to microplastic particles had no effect on uptake, survival, feeding and locomotory behaviour during the 3 weeks of exposure. Dissolved TBTH, however, was already very toxic after few days of exposure (LC50-96h < 1 ng l–1).