In breath analysis, ambient air contaminations are ubiquitous and difficult to eliminate. This study was designed to investigate the reduction of ambient air background by a lung wash-out with synthetic air. The reduction of the initial ambient air volatile organic compound (VOC) intensity was investigated in the breath of 20 volunteers inhaling synthetic air via a sealed full face mask in comparison to inhaling ambient air. Over a period of 30 minutes, breath analysis was conducted using ion mobility spectrometry coupled to a multi-capillary column. A total of 68 VOCs were identified for inhaling ambient air or inhaling synthetic air. By treatment with synthetic air, 39 VOCs decreased in intensity, whereas 29 increased in comparison to inhaling ambient air. In total, seven VOCs were significantly reduced (P-value < 0.05). A complete wash-out of VOCs in this setting was not observed, whereby a statistically significant reduction up to 65% as for terpinolene was achieved. Our setting successfully demonstrated a reduction of ambient air contaminations from the airways by a lung wash-out with synthetic air.
Ion Mobility Spectrometry (IMS) is a widely used and ‘well-known’ technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique.
Ion Mobility Spectrometry (IMS) is a widely used and `well-known’ technique of ion separation in the gaseous phase based on the differences in ion mobilities under an electric field. All IMS instruments operate with an electric field that provides space separation, but some IMS instruments also operate with a drift gas flow that provides also a temporal separation. In this review we will summarize the current IMS instrumentation. IMS techniques have received an increased interest as new instrumentation and have become available to be coupled with mass spectrometry (MS). For each of the eight types of IMS instruments reviewed it is mentioned whether they can be hyphenated with MS and whether they are commercially available. Finally, out of the described devices, the six most-consolidated ones are compared. The current review article is followed by a companion review article which details the IMS hyphenated techniques (mainly gas chromatography and mass spectrometry) and the factors that make the data from an IMS device change as a function of device parameters and sampling conditions. These reviews will provide the reader with an insightful view of the main characteristics and aspects of the IMS technique.
Rats are commonly used in medical research as they enable a high grade of standardization. The exhalome of ventilated rats has not as yet been investigated using an ion mobility spectrometer coupled with a multi-capillary column (MCC-IMS). As a first step, a rat model has to be established to measure potential biomarkers in the exhale with long-term settings, allowing constant and continuous analysis of exhaled air in time series. Therefore, eight animals were anaesthetized, prepared and ventilated for 1 h. A total of 73 peaks were directly detected with the IMS chromatogram. Thirty five of them were assigned to the ventilator system and 38 to the animals. Peak intensity varied within three measurements. The intensity of analytes of individual rats varied by a factor of up to 18. This new model will also enable continuous measurements of volatile organic compounds (VOCs) from rat's breath in long-term experiments. It is hoped that, in the future, variability and progression of VOCs can be monitored in different models of diseases using this set-up.
Rational strain engineering requires solid testing of phenotypes including productivity and ideally contributes thereby directly to our understanding of the genotype-phenotype relationship. Actually, the test step of the strain engineering cycle becomes the limiting step, as ever advancing tools for generating genetic diversity exist. Here, we briefly define the challenge one faces in quantifiying phenotypes and summarize existing analytical techniques that partially overcome this challenge. We argue that the evolution of volatile metabolites can be used as proxy for cellular metabolism. In the simplest case, the product of interest is a volatile (e.g., from bulk alcohols to special fragrances) that is directly quantified over time. But also nonvolatile products (e.g., from bulk long-chain fatty acids to natural products) require major flux rerouting that result potentially in altered volatile production. While alternative techniques for volatile determination exist, rather few can be envisaged for medium to high-throughput analysis required for phenotype testing. Here, we contribute a detailed protocol for an ion mobility spectrometry (IMS) analysis that allows volatile metabolite quantification down to the ppb range. The sensivity can be exploited for small-scale fermentation monitoring. The insights shared might contribute to a more frequent use of IMS in biotechnology, while the experimented aspects are of general use for researchers interested in volatile monitoring.
The number of publications in the field of breath analysis using different types of ion mobility spectrometers (IMS) has increased over the last few years. In this paper, the publications between 2010 and 2013 are reviewed with respect to different types of IMS such as differential mobility spectrometers, high-field asymmetric waveform ion mobility spectrometers and multi-capillary columns coupled to conventional IMS. The analytes detected by IMS and declared with significance to a specific medical question were considered further with respect to medical and analytical questions. In total, 42 different analytes were found to be detected using IMS on a high significance level and were compared to findings using other analytical methods with respect to the individual analyte.
Influence of the respirator on volatile organic compounds : an animal study in rats over 24 hours
(2015)
Long-term animal studies are needed to accomplish measurements of volatile organic compounds (VOCs) for medical diagnostics. In order to analyze the time course of VOCs, it is necessary to ventilate these animals. Therefore, a total of 10 male Sprague–Dawley rats were anaesthetized and ventilated with synthetic air via tracheotomy for 24 h. An ion mobility spectrometry coupled to multi-capillary columns (MCC–IMS) was used to analyze the expired air. To identify background contaminations produced by the respirator itself, six comparative measurements were conducted with ventilators only. Overall, a number of 37 peaks could be detected within the positive mode. According to the ratio peak intensity rat/ peak intensity ventilator blank, 22 peaks with a ratio >1.5 were defined as expired VOCs, 12 peaks with a ratio between 0.5 and 1.5 as unaffected VOCs, and three peaks with a ratio <0.5 as resorbed VOCs. The peak intensity of 12 expired VOCs changed significantly during the 24 h measurement. These results represent the basis for future intervention studies. Notably, online VOC analysis with MCC–IMS is possible over 24 h in ventilated rats and allows different experimental approaches.
Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration.Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFAor PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol,with PTFE as an alternative.