Refine
Year of publication
- 2017 (5) (remove)
Document Type
- Journal article (5) (remove)
Language
- English (5)
Has full text
- no (5) (remove)
Is part of the Bibliography
- yes (5)
Institute
- Life Sciences (5) (remove)
Publisher
Though bioprinting is a forward-looking approach in bone tissue engineering, the development of bioinks which are on the one hand processable with the chosen printing technique, and on the other hand possess the relevant mechanical as well as osteoconductive features remains a challenge. In the present study, polymer solutions based on methacrylated gelatin and methacrylated hyaluronic acid modified with hydroxyapatite (HAp) particles (5 wt%) were prepared. Encapsulation of primary human adipose derived stem cells in the HAp-containing gels and culture for 28 d resulted in a storage moduli significantly increased to 126% ± 9.6% compared to the value on day 1 by the sole influence of the HAp. Additional use of osteogenic media components resulted in an increase of storage module up to 199% ± 27.8%. Similarly, the loss moduli was increased to 370% ± 122.1% under the influence of osteogenic media components and HAp. Those changes in rheological material characteristics indicate a distinct change in elastic and viscous hydrogel properties, and are attributed to extensive matrix production in the hydrogels by the encapsulated cells, what could also be proven by staining of bone matrix components like collagen I, fibronectin, alkaline phosphatase and osteopontin. When using the cell-laden polymer solutions as bioinks to build up relevant geometries, the ink showed excellent printability and the printed grid structure's integrity remained intact over a culture time of 28 d. Again, an intense matrix formation as well as upregulation of osteogenic markers by the encapsulated cells could be shown. In conclusion, we demonstrated that our HAp-containing bioinks and hydrogels on basis of methacrylated gelatin and hyaluronic acid are on the one hand highly suitable for the build up of relevant three-dimensional geometries with microextrusion bioprinting, and on the other hand exhibit a significant positive effect on bone matrix development and remodeling in the hydrogels, as indicated by rheological measurements and staining of bone components. This makes the developed composite hydrogels an excellent material for bone bioprinting approaches.
The fluorescence of monomeric photosystem II core complexes (mPSIIcc) of the cyanobacterium Thermosynechococcus elongatus, originating from redissolved crystals, is investigated by using single-molecule spectroscopy (SMS) at 1.6 K. The emission spectra of individual mPSIIcc are dominated by sharp zero-phonon lines, showing the existence of different emitters compatible with the F685, F689, and F695 bands reported formerly. The intensity of F695 is reduced in single mPSIIcc as compared to single PSIIcc-dimers (dPSIIcc). Crystal structures show that one of the β-carotene (β-Car) cofactors located at the monomer–monomer interface in dPSIIcc is missing in mPSIIcc. This β-Car in dPSIIcc is in van der Waals distance to chlorophyll (Chl) 17 in the CP47 subunit. We suggest that this Chl contributes to the F695 emitter. A loss of β-Car cofactors in mPSIIcc preparations will lead to an increased lifetime of the triplet state of Chl 17, which can explain the reduced singlet emission of F695 as observed in SMS.
Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration.Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFAor PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol,with PTFE as an alternative.
Despite the significant potential offered by the powder coating process for finishing wood-based materials, until now it has been used almost exclusively for coating Medium Density Fiber Board (MDF). A research project aims to develop processes and substrate materials that will allow lightweight boards to be powder coated.
We report the temperature dependence of metal-enhanced fluorescence (MEF) of individual photosystem I (PSI) complexes from Thermosynechococcus elongatus (T. elongatus) coupled to gold nanoparticles (AuNPs). A strong temperature dependence of shape and intensity of the emission spectra is observed when PSI is coupled to AuNPs. For each temperature, the enhancement factor (EF) is calculated by comparing the intensity of individual AuNP-coupled PSI to the mean intensity of ‘uncoupled’ PSI. At cryogenic temperature (1.6 K) the average EF was 4.3-fold. Upon increasing the temperature to 250 K the EF increases to 84-fold. Single complexes show even higher EFs up to 441.0-fold. At increasing temperatures the different spectral pools of PSI from T. elongatus become distinguishable. These pools are affected differently by the plasmonic interactions and show different enhancements. The remarkable increase of the EFs is explained by a rate model including the temperature dependence of the fluorescence yield of PSI and the spectral overlap between absorption and emission spectra of AuNPs and PSI, respectively.