Polyurethane-bases block copolymers (TPCUs) are block-copolymers with systematically varied soft and hard segments. They have been suggested to serve as material for chondral implants in joint regeneration. Such applications may require the adhesion of chondrocytes to the implant surface, facilitating cell growth while keeping their phenotype. Thus, aims of this work were (1) to modify the surface of soft biostable polyurethane-based model implants (TPCU and TSiPCU) with high-molecular weight hyaluronic acid (HA) using an optimized multistep strategy of immobilization, and (2) to evaluate bioactivity of the modified TPCUs in vitro. Our results show no cytotoxic potential of the TPCUs. HAbioactive molecules (Mw =700kDa) were immobilized onto the polyurethane surface via polyethylenimine (PEI) spacers, and modifications were confirmed by several characterization methods. Tests with porcine chondrocytes indicated the potential of the TPCU-HA for inducing enhanced cell proliferation.
Knee osteoarthritis is a common complication and can lead to total loss of joint function in patients. Treatment by either partial or total knee replacement with appropriate UHMWPE based implantsis highly invasive, may cause complications and may show unsatisfying results. Alternatively, treatment may be done by insertion of an elastic interpositional knee spacer with optimized material characteristics.
We report the development of high performance polyurethane-based polymers modified with bioactive molecules for fabrication of such knee spacers. In order to tailor mechanical and tribological properties and to improve resist to enzymatic degradation we propose a core-shell model for the spacer with specifically adapted properties.
In vivo, cells encounter different physical and chemical signals in the extracellular matrix (ECM) which regulate their behavior. Examples of these signals are micro- and nanometer-sized features, the rigidity, and the chemical composition of the ECM. The study of cell responses to such cues is important to understand complex cell functions, some diseases, and is basis for the development of new biomaterials for applications in medical implants or regenerative medicine. Therefore, the development of new methods for surface modifications with controlled physical and chemical features is crucial. In this work, we report a new combination of micelle nanolithography (BCML) and soft micro-lithography, for the production of polyethylene glycol (PEG) hydrogels, with a micro-grooved surface and decoration with hexagonally precisely arranged gold nanoparticles (AU NPs). The Au-NPs are used for binding adhesive ligands in a well-defined density. First tests were performed by culturing human fibroblasts on the gels. Adhesion and alignment of the cells along the parallel grooves of the surface were investigated. The substrates could provide a new platform for studying cell contact guidance by micro structures, and may enable a more precise control of cell behavior by nanometrically controlled surface functionalization.
A series of novel biomedical TPCUs with different percentages of hard segment and a silicone component in the soft segment were synthesized in a multi stage one-pot method. The kinetic profiles of the urethane formation in TPCU-based copolymer systems were monitored by rheological, in line FTIR spectroscopic (React IR) and real-time calorimetric (RC1) methods. This process-analytically monitored multi step synthesis was successfully used to optimize the production of medical-grade TPCU elastomers on preparative scale (in lots of several kg) with controlled molecular structure and mechanical properties. Various surface and bulk analytical methods as well as systematic studies of the mechanic response of the elastomer end-products towards compression and tensile loading were used to estimate the bio-stability of the prepared TPCUs in vitro after 3 months. The tests suggested that high bio-stability of all polyurethane formulations using accelerating in vitro test can be attributed to the synthetic design as well as to the specific techniques used for specimen preparation, namely: (1) the annealing for reducing residual polymer surface stress and preventing IES, (2) stabilization of the morphology by long time storage of the specimens after processing before being immersed in the test liquids, (3) purification by extraction to remove the shot chain oligomers which are the most susceptible to degradation. All mechanical tests were performed on cylindrical and circular disc specimens for modelling the thickness of the meniscus implants under application-relevant stress conditions.
Soft lithography, a tool widely applied in biology and life sciences with numerous applications, uses the soft molding of photolithography-generated master structures by polymers. The central part of a photolithography set-up is a mask-aligner mostly based on a high-pressure mercury lamp as an ultraviolet (UV) light source. This type of light source requires a high level of maintenance and shows a decreasing intensity over its lifetime, influencing the lithography outcome. In this paper, we present a low-cost, bench-top photolithography tool based on ninety-eight 375 nm light-emitting diodes (LEDs). With approx. 10 W, our presented lithography set-up requires only a fraction of the energy of a conventional lamp, the LEDs have a guaranteed lifetime of 1000 h, which becomes noticeable by at least 2.5 to 15 times more exposure cycles compared to a standard light source and with costs less than 850 C it is very affordable. Such a set-up is not only attractive to small academic and industrial fabrication facilities who want to enable work with the technology of photolithography and cannot afford a conventional set-up, but also microfluidic teaching laboratories and microfluidic research and development laboratories, in general, could benefit from this cost-effective alternative. With our self-built photolithography system, we were able to produce structures from 6 μm to 50 μm in height and 10 μm to 200 μm in width. As an optional feature, we present a scaled-down laminar flow hood to enable a dust-free working environment for the photolithography process.
Adapting characteristics of biomaterials specifically for in vitro and in vivo applications is becoming increasingly important in order to control interactions between material and biological systems. These complex interactions are influenced by surface properties like chemical composition, charge, mechanical and topographic attributes. In many cases it is not useful or even not possible to alter the base material but changing surface, to improve biocompatibility or to make surfaces bioactive, may be achieved by thin coatings. An already established method is the coating with polyelectrolyte multilayers (PEM). To adjust adhesion, proliferation and improve vitality of certain cell types, we modified the roughness of PEM coatings. We included different types nanoparticles (NP’s) in different concentrations into PEM coatings for controlling surface roughness. Surface properties were characterized and the reaction of 3 different cell types on these coatings was tested.
Thermoplastic polycarbonate urethane elastomers (TPCU) are potential implant materials for treating degenerative joint diseases thanks to their adjustable rubber-like properties, their toughness, and their durability. We developed a water-containing high-molecular-weight sulfated hyaluronic acid-coating to improve the interaction of TPCU with the synovial fluid. It is suggested that trapped synovial fluid can act as a lubricant that reduces the friction forces and thus provides an enhanced abrasion resistance of TPCU implants. Aims of this work were (i) the development of a coating method for novel soft TPCU with high-molecular sulfated hyaluronic acid to increase the biocompatibility and (ii) the in vitro validation of the functionalized TPCUs in cell culture experiments.
In vitro, hydrogel-based ECMs for functionalizing surfaces of various material have played an essential role in mimicking native tissue matrix. Polydimethylsiloxane (PDMS) is widely used to build microfluidic or organ-on-chip devices compatible with cells due to its easy handling in cast replication. Despite such advantages, the limitation of PDMS is its hydrophobic surface property. To improve wettability of PDMS-based devices, alginate, a naturally derived polysaccharide, was covalently bound to the PDMS surface. This alginate then crosslinked further hydrogel onto the PDMS surface in desired layer thickness. Hydrogel-modified PDMS was used for coating a topography chip system and in vitro investigation of cell growth on the surfaces. Moreover, such hydrophilic hydrogel-coated PDMS is utilized in a microfluidic device to prevent unspecific absorption of organic solutions. Hence, in both exemplary studies, PDMS surface properties were modified leading to improved devices.