Refine
Document Type
- Conference proceeding (33)
- Journal article (29)
- Book chapter (1)
Is part of the Bibliography
- yes (63)
Institute
- Informatik (63)
Publisher
- Springer (16)
- De Gruyter (11)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e.V. (7)
- SPIE. The International Society for Optical Engineering (5)
- IEEE (4)
- IOP Publishing (4)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e. V. (3)
- GMDS e.V. (2)
- Thieme (2)
- Elsevier (1)
- Morressier (1)
- NextMed (1)
- Taylor & Francis (1)
- libreriauniversitaria.it.edizioni (1)
The paper describes how eye-tracking can be used to explore electronic patient records (EPR) in a sterile environment. As an information display, we used a system that we developed for the presentation of patient data and for supporting surgical hand disinfection. The eye-tracking was performed using the Tobii Eye Tracker 4C, and the connection between the eye-tracker and the HTML website was realized using the Tobii EyeX Chrome Extension. Interactions with the EPR are triggered by fixations of icons. The interaction was working as intended, but test persons reported a high mental load while using the system.
Die minimal-invasive Chirurgie (MIC) entwickelt sich durch den Einsatz von medizinischen Robotern wie dem da Vinci System von Intuitive Surgical stetig weiter. Hierdurch kann eine bessere oder gleichwertige Operation bei deutlich geringerer körperlicher Belastung des Operateurs erreicht werden. Dabei entstehen jedoch neue Problemstellungen wie beispielsweise Kollision zwischen Roboterarmen und die benötigte Zeit zum Einrichten einer geeigneten Roboterkonfiguration. Daher ist eine effiziente Vorbereitung und Planung der Interventionen erforderlich. Diese Arbeit präsentiert einen Ansatz für eine verbesserte Planung mit Augmented Reality (AR) und einer Robotik Simulationssoftware (RS). Die Robotik Simulation dient zur Berechnung einer Roboterkonfiguration unter Vorgabe der Port-Positionen. Augmented Reality wird verwendet, um die berechneten Pose in der realen Umgebung zu visualisieren und somit leichter in den Operationssaal zu übertragen.
This paper contributes to the automatic detection of perioperative workflow by developing a binary endoscope localization. Automated situation recognition in the context of an intelligent operating room requires the automatic conversion of low level cues into more abstract high level information. Imagery from a laparoscope delivers rich content that is easy to obtain but hard to process. We introduce a system which detects if the endoscope's distal tip is inside or outsiede the patient based on the endoscope video. This information can be used as one parameter in a situation recognition pipeline. Our localization performs in real-time at a video resolution of 1280x720 and 5-fold cross validation yields mean F1-scores of up to 0,94 on videos of 7 laparoscopies.
Introduction: Even if there is a standard procedure of CI surgery, especially in pediatric surgery surgical steps often differ individually due to anatomical variations, malformations or unforseen events. This is why every surgical report should be created individually, which takes time and relies on the correct memory of the surgeon. A standardized recording of intraoperative data and subsequent storage as well as text processing would therefore be desirable and provides the basis for subsequent data processing, e.g. in the context of research or quality assurance.
Method: In cooperation with Reutlingen University, we conducted a workflow analysis of the prototype of a semi-automatic checklist tool. Based on automatically generated checklists generated from BPMN models a prototype user interface was developed for an android tablet. Functions such as uploading photos and files, manual user entries, the interception of foreseeable deviations from the normal course of operations and the automatic creation of OP documentation could be implemented. The system was tested in a remote usability test on a petrous bone model.
Result: The user interface allows a simple intuitive handling, which can be well implemented in the intraoperative setting. Clinical data as well as surgical steps could be individually recorded and saved via DICOM. An automatic surgery report could be created and saved.
Summary: The use of a dynamic checklist tool facilitates the capture, storage and processing of surgical data. Further applications in clinical practice are pending.
Stent graft visualization and planning tool for endovascular surgery using finite element analysis
(2014)
Purpose: A new approach to optimize stent graft selection for endovascular aortic repair is the use of finite element analysis. Once the finite element model is created and solved, a software module is needed to view the simulation results in the clinical work environment. A new tool for Interpretation of simulation results, named Medical Postprocessor, that enables comparison of different stent graft configurations and products was designed, implemented and tested. Methods Aortic endovascular stent graft ring forces and sealing states in the vessel landing zone of three different configurations were provided in a surgical planning software using the Medical Imaging Interaction Tool Kit (MITK) Software system. For data interpretation, software modules for 2D and 3D presentations were implemented. Ten surgeons evaluated the software features of the Medical Postprocessor. These surgeons performed usability tests and answered questionnaires based on their experience with the system.
Results: The Medical Postprocessor visualization system enabled vascular surgeons to determine the configuration with the highest overall fixation force in 16 ± 6 s, best proximal sealing in 56±24 s and highest proximal fixation force in 38 ± 12 s. The majority considered the multiformat data provided helpful and found the Medical Postprocessor to be an efficient decision support system for stent graft selection. The evaluation of the user interface results in an ISONORMconform user interface (113.5 points).
Conclusion: The Medical Postprocessor visualization Software tool for analyzing stent graft properties was evaluated by vascular surgeons. The results show that the software can assist the interpretation of simulation results to optimize stent graft configuration and sizing.
Purpose
Supporting the surgeon during surgery is one of the main goals of intelligent ORs. The OR-Pad project aims to optimize the information flow within the perioperative area. A shared information space should enable appropriate preparation and provision of relevant information at any time before, during, and after surgery.
Methods
Based on previous work on an interaction concept and system architecture for the sterile OR-Pad system, we designed a user interface for mobile and intraoperative (stationary) use, focusing on the most important functionalities like clear information provision to reduce information overload. The concepts were transferred into a high-fidelity prototype for demonstration purposes. The prototype was evaluated from different perspectives, including a usability study.
Results
The prototype’s central element is a timeline displaying all available case information chronologically, like radiological images, labor findings, or notes. This information space can be adapted for individual purposes (e.g., highlighting a tumor, filtering for own material). With the mobile and intraoperative mode of the system, relevant information can be added, preselected, viewed, and extended during the perioperative process. Overall, the evaluation showed good results and confirmed the vision of the information system.
Conclusion
The high-fidelity prototype of the information system OR-Pad focuses on supporting the surgeon via a timeline making all available case information accessible before, during, and after surgery. The information space can be personalized to enable targeted support. Further development is reasonable to optimize the approach and address missing or insufficient aspects, like the holding arm and sterility concept or new desired features.
Checklists are a valuable tool to ensure process quality and quality of care. To ensure proper integration in clinical processes, it would be desirable to generate checklists directly from formal process descriptions. Those checklists could also be used for user interaction in context-aware surgical assist systems. We built a tool to automatically convert Business Process Model and Notation (BPMN) process models to checklists displayed as HTML websites. Gateways representing decisions are mapped to checklist items that trigger dynamic content loading based on the placed checkmark. The usability of the resulting system was positively evaluated regarding comprehensibility and end-user friendliness.
Hintergrund: Endoskopische Operationsverfahren haben sich als Goldstandard in der Nasennebenhöhlen-(NNH-)Chirurgie etabliert. Den sich daraus ergebenden Herausforderungen für die chirurgische Ausbildung kann durch den Einsatz von Virtuelle-Realität-(VR-)Trainingssimulatoren begegnet werden. Bislang wurde eine Reihe von Simulatoren für NNH-Operationen entwickelt. Frühere Studien im Hinblick auf den Trainingseffekt wurden jedoch nur mit medizinisch vorgebildeten Probanden durchgeführt oder es wurde nicht über dessen zeitlichen Verlauf berichtet.
Methoden: Ein NNH-CT-Datensatz wurde nach der Segmentierung in ein 3-dimensionales, polygonales Oberflächenmodell überführt und mithilfe von originalem Fotomaterial texturiert. Die Interaktion mit der virtuellen Umgebung erfolgte über ein haptisches Eingabegerät. Während der Simulation wurden die Parameter Eingriffsdauer und Fehleranzahl erfasst. Zehn Probanden absolvierten jeweils eine Trainingseinheit bestehend aus je 5 Übungsdurchläufen an 10 aufeinanderfolgenden Tagen.
Ergebnisse: Vier Probanden verringerten die benötigte Zeit um mehr als 60% im Verlauf des Übungszeitraums. Vier der Probanden verringerten ihre Fehleranzahl um mehr als 60%. Acht von 10 Probanden zeigten eine Verbesserung bezüglich beider Parameter. Im Median wurde im gesamten gemessenen Zeitraum die Dauer des Eingriffs um 46 Sekunden und die Fehleranzahl um 191 reduziert. Die Überprüfung eines Zusammenhangs zwischen den 2 Parametern ergab eine positive Korrelation.
Schlussfolgerung: Zusammenfassend lässt sich feststellen, dass das Training am NNH-Simulator auch bei unerfahrenen Personen die Performance beträchtlich verbessert, sowohl in Bezug auf die Dauer als auch auf die Genauigkeit des Eingriffs.
In this paper a method for the generation of gSPM with ontology-based generalization was presented. The resulting gSPM was modeled with BPMN/BPMNsix in an efficient way and could be executed with BPMN workflow engines. In the next step the implementation of resource concepts, anatomical structures, and transition probabilities for workflow execution will be realized.
The increasing heterogenecity of students at German Universities of Applied Sciences and the growing importance of digitization call for a rethinking of teaching and learning within higher education. In the next years, changing the learning ecosystem by developing and reflecting upon new teaching and learning techniques using methods of digitalization will be both - most relevant and very challenging. The following article introduces two different learning scenarios, which exemplify the implementation of new educational models that allow discontinuity of time and place, technology and process in teaching and learning. Within a blended learning apporach, the first learning scenario aims at adapting and individualizing the knowledge transfer in the course Foundations of Computer Science by providing knowledge individually and situation-specifically. The second learning scenario proposes a web-based tool to facilitate digital learning environments and thus digital learning communities and the possibility of computer-supported learning. The overall aim of both learning scenarios is to enhance learning for diverse groups by providing a different smart learning ecosystem in stepping away from a teacher-based to a student-centered approach. Both learning scenarios exemplarily represent the educational vision of Reutlingen University - its development into an interactive university.