Refine
Document Type
- Journal article (3)
- Conference proceeding (2)
Language
- English (5)
Is part of the Bibliography
- yes (5)
Institute
- Technik (5)
Publisher
- ASME (1)
- De Gruyter (1)
- Elsevier (1)
- Springer (1)
- University of Colorado (1)
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.
Hearing contact lens (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator (PEA). In order to evaluate and maximizethe HCL´s performance, a model of the HCL coupled to the middle ear was developed using finite element (FE)approach. To validate the model, vibrational measurements on the HCL and temporal bones were performed using a Laser-Doppler-Vibrometer (LDV). The model was validated step by step starting with HCL only. Then a silicone cap was fitted onto the HCL to provide an interface between the HCL and the tympanic membrane. The HCL was placed on the tympanic membrane and additional measurements were performed to validate the coupled model. The model was used to evaluate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL. Moreover, deeper insight was gained into the feedback behavior, which causes whistling sounds, and the contact between the HCL and tympanic membrane.
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL’s performance, a model of the HCL coupled to the middle ear was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a Laser-Doppler-Vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model and additional LDV measurements on temporal bones were performed to validate the coupled model. The coupled model was used to evaluate the equivalent sound pressure of the HCL. Moreover, a deeper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.
Model-based hearing diagnosis based on wideband tympanometry measurements utilizing fuzzy arithmetic
(2019)
Today's audiometric methods for the diagnosis of middle ear disease are often based on a comparison of measurements with standard curves that represent the statistical range of normal hearing responses. Because of large inter-individual variances in the middle ear, especially in wideband tympanometry (WBT), specificity and quantitative evaluation are greatly restricted. A new model-based approach could transform today's predominantly qualitative hearing diganostics into a quantitative and tailored, patient-specific diagnosis, by evaluating WBT measurements with the aid of a middle-ear model. For this particular investigation, a finite element model of a human ear was used. It consisted of an acoustic ear canal and a tympanic cavity model, a middle-ear with detailed nonlinear models of the tympanic membrane and annular ligament, and a simplified inner-ear model. This model has made it possible to identify pathologies from measurements, by analyzing the parameters through senstivity studies and parameter clustering. Uncertainties due to the lack of knowledge, subjectivity in numerical implementation and model simplification are taken into account by the application of fuzzy arithmetic. The most confident parameter set can be determined by applying an inverse fuzzy method on the measurement data. The principle and the benefits of this model-based approach are illustrated by the example of a two-mass oscillator, and also by the simulation of the energy absorbance of an ear with malleus fixation, where the parameter changes that are introduced can be determined quantitatively through the system identification.
Investigation of tympanic membrane influences on middle-ear impedance measurements and simulations
(2020)
This study simulates acoustic impedance measurements in the human ear canal and investigates error influences due to improperly accounted evanescence in the probe’s near field, cross-section area changes, curvature of the ear canal, and pressure inhomogeneities across the tympanic membrane, which arise mainly at frequencies above 10 kHz. Evanescence results from strongly damped modes of higher order, which can only be found in the near field of the sound source and are excited due to sharp cross-sectional changes as they occur at the transition from the probe loudspeaker to the ear canal. This means that different impedances are measured depending on the probe design. The influence of evanescence cannot be eliminated completely from measurements, however, it can be reduced by a probe design with larger distance between speaker and microphone. A completely different approach to account for the influence of evanescence is to evaluate impedance measurements with the help of a finite element model, which takes the precise arrangement of microphone and speaker in the measurement into account. The latter is shown in this study exemplary on impedance measurements at a tube terminated with a steel plate. Furthermore, the influences of shape changes of the tympanic membrane and ear canal curvature on impedance are investigated.